• 제목/요약/키워드: RMS detector

검색결과 42건 처리시간 0.039초

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

자동 이득제어 루프를 이용한 CMOS RF 전력 검출기 (A CMOS RF Power Detector Using an AGC Loop)

  • 이동열;김종선
    • 전자공학회논문지
    • /
    • 제51권11호
    • /
    • pp.101-106
    • /
    • 2014
  • 본 논문에서는 자동 이득 제어 회로를 이용한 와이드 다이나믹 레인지 RF root-mean-square (RMS) 전력 검출기를 소개한다. 제안하는 자동 이득 제어는 voltage gain amplifier (VGA), RMS 변환 블록, 이득 조절 블록으로 구성되어 있다. VGA는 dB-linear한 이득 관계를 갖는 캐스코드 VGA를 사용하였다. 제안하는 RMS 변환은 입력 신호 전 파장의 제곱 변환을 이용하여 RMS에 비례하는 DC 전압을 출력한다. 제안하는 RMS 전력 검출기는 500MHz에서 5GHz에서 작동하며 검출 범위는 0 dBm에서 -70dBm 이상의 신호를 -4.53 mV/dBm의 비율로 검출한다. 제안하는 RMS 전력 검출기는 TSMC 65nm 공정을 사용하여 설계되었으며 1.2V에서 5mW의 전력소비를 갖는다. 칩 레이아웃 면적은 $0.0097mm^2$이다.

RMS Detector of Multiharmonic Signals

  • Petrovic, Predrag B.
    • ETRI Journal
    • /
    • 제35권3호
    • /
    • pp.431-438
    • /
    • 2013
  • This paper presents a new realization of the implicit root-mean-square (RMS) detector, employing three second-generation current conveyors and MOS transistors. The proposed circuit can be applied in measuring the RMS value of complex, periodic signals, represented in the form of the Fourier series. To verify the theoretical analysis, circuit Simulation Program with Integrated Circuit Emphasis simulations and experiment results are included, showing agreement with the theory.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.

단일 에지 이진위상검출기를 사용한 저 지터 클록 데이터 복원 회로 설계 (Design of low jitter CDR using a single edge binary phase detector)

  • 안택준;공인석;임상순;강진구
    • 전기전자학회논문지
    • /
    • 제17권4호
    • /
    • pp.544-549
    • /
    • 2013
  • 본 논문은 CDR회로의 지터 감소를 위해 변형된 이진 위상검출기(뱅뱅위상 검출기- BBPD) 회로를 제안하였다. 제안된 PD는 하나의 에지를 사용함으로써 전압리플을 줄여, 제안한 PD를 적용하여 설계한 CDR회로는 감소된 지터 특성을 보였다. CMOS 0.13um 공정을 사용하여 설계하였고 제안한 위상검출기를 포함하는 클럭데이터 복원회로는 모의실험결과 16.9mW 전력소비에 peak-peak 지터는 10.96ps, rms 지터는 0.89ps을 보였다.

2.5Gbps 시리얼 데이터 링크 CMOS 트랜시버의 설계 (Design of a 2.5Gbps Serial Data Link CMOS Transceiver)

  • 이흥배;오운택;소병춘;황원석;김수원
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2003년도 하계종합학술대회 논문집 II
    • /
    • pp.1185-1188
    • /
    • 2003
  • This paper describes a design for a 2.5Gb/s serial data link CMOS transceiver based on the InfiniBand$^{TM}$ specification. The transceiver chip integrates data serializer, line driver, Tx PLL, deserializer, clock recovery, and lock detector. The designed transceiver is fabricated in a 0.25 ${\mu}{\textrm}{m}$ CMOS mixed-signal, 1-poly, 5-metal process. The first version chip occupies a 3.0mm x 3.3mm area and consumes 450mW with 2.5V supply. In 2.5 Gbps, the output jitter of transmitter measured at the point over a 1.2m, 50Ω coaxial cable is 8.811ps(rms), 68ps(p-p). In the receiver, VCO jitter is 18.5ps(rms), 130ps(p-p), the recovered data are found equivalent to the transmitted data as expected. In the design for second version chip, the proposed clock and data recovery circuit using linear phase detector can reduce jitter in the VCO of PLL.L.

  • PDF

원자력 및 핵의학 분야용 Total RMS (Radiation Monitoring System)의 설계 (Design of Total RMS(Radiation Monitoring System) for nuclear and nuclear medicine)

  • 고태영;이주현;이승호
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.158-161
    • /
    • 2017
  • 본 논문에서는 원자력 및 핵의학 분야용 Total RMS(Radiation Monitoring System)를 제안한다. 제안하는 시스템은 Stack Monitor, Area Monitor, Water(Liquid) Monitor 등을 하나의 시스템으로 확장 및 제어할 수 있는 장비로 각 방사선 검출기에서 측정된 신호를 통합 모니터링 할 수 있다. 제안하는 시스템은 해당 방사선을 검출하는 Sensor Module, 방사선 검출 위치에 인접한 곳에서 방사선량을 디스플레이 하는 Display Unit, 검출된 방사선량이 위험 수준에 도달시 경보를 알리는 Alarm Unit, 각 모니터링에서 측정된 방사선량들을 취합하고 저장하여 원격 감시 시스템에 내용을 전달하는 Main Hub, 원격지에서 측정된 방사선량 상태를 일목요연하게 디스플레이 하는 RMS Monitoring Unit 등으로 구성된다. 제안된 원자력 및 핵의학 분야용 Total RMS의 성능을 평가하기 위하여 공인시험기관에서 실험한 결과, 측정 불확도가 8.5%이하로 측정되어 국제 표준인 ${\pm}15%$ 이하에서 정상동작 됨이 확인되었다.

소내방사선 감시시스템의 개발 (Development of Radiation Monitoring System)

  • 김시환;하달규;홍기성;이석홍
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.50-53
    • /
    • 1999
  • In this paper, we developed a LCU which can be apply Radiation Monitoring System. LCU composed of Controller and Detector Pulse Input Module and so on. we explained concept of PIG Monitor and a study of Radiation Algorithm. Keywords RMS, LCU, DPIM, CPM

  • PDF