Browse > Article
http://dx.doi.org/10.6113/JPE.2010.10.2.203

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm  

Jeong, Jong-Kyou (Dept. of Electrical Engineering, Myongji University)
Lee, Ji-Heon (Dept. of Electrical Engineering, Myongji University)
Han, Byung-Moon (Dept. of Electrical Engineering, Myongji University)
Publication Information
Journal of Power Electronics / v.10, no.2, 2010 , pp. 203-209 More about this Journal
Abstract
This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.
Keywords
DFT (Discrete Fourier Transform); DVR (Dynamic Voltage Restorer); Line-Interactive; PLL(Phase-Locked Loop); RMS variation detector; Voltage sag or Interruption;
Citations & Related Records

Times Cited By Web Of Science : 0  (Related Records In Web of Science)
Times Cited By SCOPUS : 2
연도 인용수 순위
1 M. Newman, D. Holmes, J. Nielsen, F. Blaabjerg, "A dynamic voltage restorer with selective harmonic compensation at medium voltage level," IEEE Trans. on Industry Applications, Vol.41, No.6, pp.1744-1753, Nov./Dec. 2005.   DOI   ScienceOn
2 A. Florio and A. Mariscotti, "Voltage sag detection based on rectified voltage processing," IEEE Trans. on Power Delivery, Vol.19, No.4, pp. 1962-1967, Oct. 2004.   DOI   ScienceOn
3 R. Naidoo and P. Pillay, "A new method of voltage sag and swell detection," IEEE Trans. on Power Delivery, Vol.22, No.2, pp. 1056-1063, Apr. 2007.   DOI   ScienceOn
4 B. Han and B. Bae, "Novel phase-locked loop using adaptive linear combiner," Letter Section of IEEE Trans. on Power Delivery, Vol. 21, No. 1, pp. 513-514, Jan. 2006.   DOI   ScienceOn
5 N. Woodley, L. Morgan, A. Sundaram, "Experience with an inverter-based dynamic voltage restorer," IEEE Trans. on Power Delivery, Vol.14, No.3, pp.1181-1186, Jul. 1999.   DOI   ScienceOn
6 B. Han, B. Bae, H. Kim, S. Baek, "Combined operation of unified power quality conditioner with distributed generation," IEEE Trans. on Power Delivery, Vol.21, No.1, pp.330-338, Jan. 2006.   DOI   ScienceOn
7 C. Zhan, V. Ramachandaramurthy, A. Arulampalam, C. Fitzer, S. Kromlidis, M. Bames, N. Jenkins, "Dynamic voltage restorer based on voltagespace vector PWM control," IEEE Trans. on Industry Applications, Vol.37, No.6, pp.1855-1863, Nov./Dec. 2001.   DOI   ScienceOn