• 제목/요약/키워드: RMS Voltage

검색결과 308건 처리시간 0.024초

Three-Phase Line-Interactive Dynamic Voltage Restorer with a New Sag Detection Algorithm

  • Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • 제10권2호
    • /
    • pp.203-209
    • /
    • 2010
  • This paper describes the development of a three-phase line-interactive DVR with a new sag detection algorithm. The developed detection algorithm has a hybrid structure composed of an instantaneous detector and RMS-variation detectors. The source voltage passes through the sliding-window DFT and RMS calculator, and the instantaneous sag detector. If an instantaneous sag is detected, the RMS variation detector-1 is selected to calculate the RMS variation. The RMS variation detector-2 is selected when the instantaneous sag occurs under the operation of the RMS variation detector-1. The feasibility of the proposed algorithm is verified through computer simulations and experimental work with a prototype of a line-interactive DVR with a 3kVA rating. The line-interactive DVR with the proposed algorithm can compensate for an input voltage sag or an interruption within a 2ms delay. The developed DVR can effectively compensate for a voltage sag or interruption in sensitive loads, such as computers, communications equipment, and automation equipment.

샘플링 시점의 위상각 동기화를 이용한 계통전압 실효값의 정확한 계산 방법 (Accurate Calculation of RMS Value of Grid Voltage with Synchronization of Phase Angle of Sampled Data)

  • 함도현;김수빈;송승호;이현영
    • 전력전자학회논문지
    • /
    • 제23권6호
    • /
    • pp.381-388
    • /
    • 2018
  • A novel and simple algorithm for accurate calculation of RMS voltage is proposed in a digitally controlled grid-tie inverter system. Given that the actual frequency of grid voltage is continuously changing, the constant sampling frequency cannot be a multiple number of the fundamental frequency. Therefore, the RMS of grid voltage contains periodic oscillations due to the differences in the phase angle of sampled data during calculation. The proposed algorithm precisely calculates and updates the initial phase angle of the first sampled voltage in a half-cycle period using phase-locked loop, which is commonly utilized for phase angle detection in grid-tie inverter systems. The accuracy and dynamic performance of the proposed algorithm are compared with those of other algorithms through various simulations and experiments.

순시전력 합성 개념을 이용한 가상주파수 3상 실효전압 계측기법 (3-Phase RMS Voltage Measurement Method of Virtual Frequence using Instantaneous Power Component Concept)

  • 박성미;양지훈;박성준
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.251-257
    • /
    • 2019
  • This paper proposes a new measurement method using virtual power concept to measure the effective value of 3-phase voltage with variable frequency. The conventional effective value measurement method uses a method of integrating data sampled during one or half cycle of the power voltage and averaging it. In this method, since the effective voltage is calculated every cycle, a time delay occurs in the measured effective voltage and it is s a problem to measure the effective value of a device whose frequency varies from time to time, such as a generator. The proposed 3-phase voltage rms measurement method has an advantage that it can measure accurate voltage RMS value regardless of measurement frequency variation. In particular, there is an advantage in that it is possible to measure a 3-phase effective voltage rather than an average value of the effective voltage of each phase in a 3-phase unbalance voltage. In addition, the validity of the proposed method is verified by using the Psim simulation tool and the experimental results are analyzed by applying the proposed measurement algorithm to the actual three phase synchronous generator voltage measurement experiment.

음향 방출을 이용한 저어널 베어링의 조기 파손 감지(III) -저어널 베어링 AE 진단 시스템 개발- (Acoustic Emission Monitoring of Incipient Failure in Journal Bearings( III ) - Development of AE Diagnosis System for Journal Bearings -)

  • 정민화;조용상;윤동진;권오양
    • 비파괴검사학회지
    • /
    • 제16권3호
    • /
    • pp.155-161
    • /
    • 1996
  • 회전 기계의 저어널 베어링 상태를 음향 방출(AE) 기술을 활용하여 감시하기 위한 진단 시스템을 개발하였다. AE 기술은 베어링 시스템에 있어서 비정상 상태를 탐지하기 위하여 이용된다 모의 저어널 베어링시스템을 이용한 실험과 실제 발전 설비에 대한 적용 시험의 결과로부터 AE 신호 파라메타 중에서 rms voltage가 가장 유효한 것으로 판명되었으며, 이러한 연구 결과를 토대로 하여 진단 시스템의 알고리즘과 판단 기준들이 설정되었다. 베어링 진단 시스템은 AE 센서 및 전치앰프로 구성된 신호 감지부, AE rms voltage를 측정하기 위한 rms-to-DC 변환 회로부로 구성된 신호 처리부, A/D 변환기를 이용하여 rms voltage 신호를 PC에 연결해 주는 인터페이스부, 베어링 상태 보기와 진단 프로그램을 포함하는 그래픽 디스플레이 및 소프트웨어부의 4부분으로 구성된다.

  • PDF

관전압 증가에 기인한 산란선 발생의 화질 영향 연구 (A Study for Effects of Image Quality due to Scatter Ray produced by Increasing of Tube Voltage)

  • 박지군;전제훈;양승우;김교태;최일홍;강상식
    • 한국방사선학회논문지
    • /
    • 제11권7호
    • /
    • pp.663-669
    • /
    • 2017
  • 진단목적의 방사선 의료 영상의 활용의 증가에 따라 환자의 피폭 선량 증가와 의료영상의 진단적 가치 저하에 기여하는 산란선의 관리 및 저감을 위한 연구는 필수적이라 할 수 있다. 이에 본 연구에서는 관전압 증가에 따른 산란선의 증감이 영상 화질에 미치는 영향을 분석하였다. 이를 위해 ANSI 흉부 팬텀을 이용하여, 관전압 변화에 따른 산란선 발생 비율을 측정하고, 산란선의 발생에 따른 화질 영향을 RMS(Root Mean Square) 입상성 평가, RSD(Relative Standard Deviation) 및 NPS(Noise Power Spectrum) 분석을 통해 고찰하였다. 관전압 증가에 따른 산란선 발생비율은 73 kV 관전압에서 48.8%, 93 kV 관전압 인가시 80.1%로 점차 증가하는 것으로 확인되었다. 관전압 증가에 따른 산란선 증가의 화질 영향을 분석하기 위한 RMS 분석 결과, 관전압 증가에 따른 RMS 값이 증가하는 것으로 나타나 영상의 입상성이 떨어지는 결과로 도출되었다. 공간주파수 2.5 lp/mm에서의 NPS 값 또한 관전압 73 kV 인가에 비해 93kV 관전압 증가시 20% 정도 영상의 잡음이 증가하는 것으로 나타났다. 본 연구를 통하여 관전압 변화에 따른 산란선 발생이 화질에 미치는 영향을 확인할 수 있었으며, 이러한 연구 결과는 의료영상 품질 개선을 위한 연구의 기초 자료로서 활용 가능할 것으로 판단된다.

열처리에 따른 3Cr-1Mo강의 Barkhausen noise 특성 (Barkhausen Noise Characteristics of 3Cr-1Mo Steel with Heat-treatment)

  • 남영현
    • 열처리공학회지
    • /
    • 제21권4호
    • /
    • pp.199-204
    • /
    • 2008
  • The destructive method is reliable and widely used for evaluating the properties of material but it is time-consuming and difficult to prepare specimens from in-service industrial facilities. In the present research, Barkhausen Noise (BN) has been used to evaluate changes of mechanical properties due to heat treatment condition. The BN voltage (rms voltage) was measured with grain size. The rms voltage of BN increased with the heat treatment temperature ($870{\sim}1000^{\circ}C$) because the grain size increased with the temperature. The rms voltage of BN decreased with various heat treatment processes, such as quenched, tempered and PWHT. The BN can be used for the nondestructive evaluation of the forged reactor vessels. and moreover, it may be effectively used in the field application.

Current and voltage loading tests off resistive SFCL

  • 최효상;현옥배;김혜림;황시돌;박권배
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.241-246
    • /
    • 2002
  • We have performed the current and voltage loading tests of resistive superconducting fault current limiters (SFCLS) based on $YBa_2$$Cu_3$$O_{7}$(YBCO) films with the diameter of 2 inch. The SFCL consists of meander-type YBCO stripes covered with 200 nm Au layer grown in situ for current shunt and heat dispersion at hot spots. The minimum quench current of an SFCL unit was about 25 Apeak. Seven SFCL units were connected in parallel fur the current load ing tests at power source of 100 $V_{rms}$ $/2,000A_{rms}$. This SFCL units had maximum limiting current of 170 Apeak during the fault instant and then successfully controlled the fault current below 100 Apeak within 1~2 msec after short circuit. Increased short current also reduced the quench completion time with little change of current limiting characterization. We connected six SFCL units in series fur the voltage loading tests at power source of $1,200 V_{rms}$/170 $A_{rms}$ at this time. The shunt resistors were inserted into each SFCL unit to eliminate power imbalance originated from serial connection of SFCL units. Each SFCL unit was quenched simultaneously during the fault condition. The current increased up to 40 $A_{peak}$ and decreased to 14 $A_{peak}$ after 3 cycles. Quench was completed within 1 msec after the fault. We confirmed operating characteristics of 140 kVA($120 A_{rms}$ $\times$ 1,200 $V_{rms}$) SFCL and presented the manufacturing possibility of 3.3 kV SFCL using 4 inch YBCO films.BCO films.lms.

  • PDF

NEW ADAPTIVE METHOD FOR VOLTAGE SAG AND SWELL DETECTION

  • Mohamed, Mansour A.
    • 한국융합학회논문지
    • /
    • 제4권1호
    • /
    • pp.33-41
    • /
    • 2013
  • This paper presents an adaptive recursive least squares algorithm (ARLS) for detecting voltage sag and voltage swell events in power systems. Different methods have been developed to detect voltage sag and voltage swell. Some of them use window techniques, which are too slow when voltage sag or swell mitigation is required. Others depend on the extraction of a single non-stationary sinusoidal signal out of a given multi-components input signal, and therefore they don't consider the harmonic components in calculating the voltage root mean square value (rms). The method, proposed in this paper, is capable of estimating the voltage rms taking into account all harmonic components. The method is tested by applying it to different, simulated signals using ATP program, and compared with voltage sag detection algorithms.

다기능 디지털 전압기록장치 시스템 개발 (Development of new Multifunction Voltage Recorder)

  • 손수국;최상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.693-696
    • /
    • 1999
  • This paper describes a new voltage recorder for the voltage management of a power distribution line by using a new voltage measurement technique. The RMS(Root Mean Square) voltage measurement for the power line under the assumption of a sinusoidal input voltage is taken by the full-wave rectifier, half-adder utilizing operational amplifier(OP) circuit. A/D converter utilizing a dual slope converter converts an analog voltage signal into a serial pulse. The pulse is counted with a single chip micro-controller, converted with the RMS voltage, and saved into a flash memory. In the last, a new voltage recorder with compact size and multifunction is developed. Also, Voltage Management System that can analyze the stored data via RS-232C cable is developed based on Windows 95 and Visual C++.

  • PDF

90-265$V_{rms}$ 입력범위를 갖는 단일전력단 역률개선 컨버터 (A Single-Stage Power Factor Correction Converter for 90-265$V_{rms}$ Line Applications)

  • 구관본
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.145-149
    • /
    • 2000
  • A single-stage power factor correction AC/DC converter with a simple link voltage suppressing circuit (LVSC) for the universal line application is proposed. Using this simple circuit a low link voltage can be realized without deadbands at line zero-crossings. The proposed converter is analyzed and a prototype converter with 5C, 12V output is implemented to verify the performance. The experimental results show that the link voltage stress and efficiency are about 447V and 81%, respectively.

  • PDF