• Title/Summary/Keyword: R-곡선법

Search Result 240, Processing Time 0.021 seconds

Simultaneous Analysis of Pesticides in Aqueous Sample by HF-LPME (HF-LPME를 이용한 수용액 시료 내 농약의 동시 분석)

  • Nam, Jang-Woo;Lee, Kang-Jin;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.56 no.5
    • /
    • pp.583-590
    • /
    • 2012
  • The HF (Hollow fiber) extraction method was optimized to analysis seven species of pesticides in aqueous sample and analyzing samples by GC/MS. Hollow fiber extraction showed good efficiency when it was conducted under these conditions: organic solvent was toluene and agitation speed was 1200 rpm. The 15% concentration of NaCl was optimized when it was experimented between 5% and 25%. The equilibrium time was determined at 15 minutes. The pH 5 showed the best effect on the extraction efficiency. The linearities of calibration curves of seven species were good with correlation of regression ($r^2$) over 0.995 when they were experimented over a concentration range of $5{\mu}g/L$ to $50{\mu}g/L$. The analytical data exhibited the detection of limits (LODs) range of $0.37{\mu}g/L$ to $1.23{\mu}g/L$ and the limit of quantification (LOQs) range of $1.19{\mu}g/L$ to $3.91{\mu}g/L$. The optimized HF-LPME extraction method provides a simple and effective preparation and requires small amount of organic solvents and samples compared to conventional pre-treatment methods.

A study on the separation and determination of the rare earth Elements by the AG® 50W-X8 cation exchange resin (AG® 50W-X8 양이온교환수지를 이용한 희토류원소의 분리와 분석에 관한 연구)

  • Lee, Jung Sook;Choi, Beom Suk
    • Analytical Science and Technology
    • /
    • v.21 no.4
    • /
    • pp.272-278
    • /
    • 2008
  • Methods to separate 14 rare earth elements (REEs) and yttrium by the $AG^{(R)}$ 50W-X8 cation exchange resin, and to determine REEs by inductively coupled plasma atomic emission spectrophotometry (ICP-AES) were described. Ion exchange capacities of REEs on the resin were so high that the REEs were quantitatively ion exchanged under the flow rate of 0.3~1.0 mL/min at pH 1~6. The breakthrough capacity curve of the REEs showed that ion exchange capacities of light REEs (Cerium group) were greater than that of the heavy REEs (Yttrium group). When $200{\mu}g$ of each REEs was ion exchanged on 100 mg of resin, most of the heavy REEs were quantitatively desorbed with 10 mL of 2.0 M of $HNO_3$, while most of the light REEs with 30 mL. The method was applied to the monazite sample. The REEs could be separated from matrix, since ion exchange capacities of matrix ions of Ca, Ti, Mg, Mn were much lower than that of the REEs. However the relative standard deviations of the analytical results by the present method were not improved, as high as 1~5%.

Influence of Temperature on the Photosynthetic Responses of Benthic Diatoms: Fluorescence Based Estimates (온도가 저서규조류 광합성 반응에 미치는 영향: 형광을 이용한 추정)

  • Yun, Mi-Sun;Lee, Choon-Hwan;Chung, Ik-Kyo
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.14 no.2
    • /
    • pp.118-126
    • /
    • 2009
  • Benthic diatoms are very important primary producers in understanding estuary ecosystems and their productions are largely varied by their photo-physiological characteristics. The short-term effects of increased temperature on the photosynthetic and photo-physiological characteristics of cultured different species of benthic diatoms (Navicula sp., Nitzschia sp., Cylindrotheca closterium, and Pleurosigma elongatum) were investigated by measuring their PSII-fluorescence kinetics using a Diving-PAM. Photosynthesis versus irradiance curves were measured every two hours at six different temperatures (10, 15, 20, 25, 30, and $35^{\circ}C$) for twenty-four hour. The effective quantum yield of PSII ($\Phi_{PSII}$) for most of the species showed a decreasing trend with increased temperature. The relative maximum electron transport rate (rETRmax) was significantly increased up to the optimum temperature level and then sharply decreased. Relative to the values of other parameters, the maximum light use coefficient ($\alpha$) was not substantially changed at lower temperature levels (<$30^{\circ}C$) but significantly decreased only at higher temperatures (30 and $35^{\circ}C$). The light saturation coefficient ($E_K$) mirrored the rETRmax temperature response. In regards to the temperature acclimation abilities of the four species with time, Navicula sp. and C. closterium acclimated to short-term changes in temperature through their photo-physiological adjustments.

Simultaneous Determination of Tetracycline Antibiotics by 3-Phase Hollow Fiber-Liquid Phase Microextraction (HF-LPME) and HPLC-UV/Vis (3-상 속빈 섬유-액체상 미량추출법(HF-LPME)과 HPLC-UV/Vis을 이용한 Tetracycline류 항생제 동시분석)

  • Oh, Woong Kyo;Myung, Seung-Woon
    • Journal of the Korean Chemical Society
    • /
    • v.58 no.6
    • /
    • pp.535-542
    • /
    • 2014
  • A simple and efficient preconcentration method was developed using three-phase liquid phase microextraction prior to HPLC-UV for simultaneous extraction and determination of tetracycline antibiotics (tetracycline, oxytetracycline, and chlortetracycline). The tetracycline antibiotics were separated simultaneously on a column ($C_8$, $3.0{\times}150mm$, $3{\mu}m$) with high selectivity and sensitivity using gradient elution. Under optimized conditions (extraction solvent, heptanal; pH of donor, 9.0; pH of acceptor, 1.0; stirring speed, 700 rpm; NaCl salt, 0%; and extraction time, 60 min), enrichment factors (EF) were between 5.6 and 22.3. The limit of detection (LOD) and limit of quantitation (LOQ) in the spiked urine matrix were in the concentration range of $0.08{\sim}0.8{\mu}g/mL$ and $0.4{\sim}1.6{\mu}g/mL$, respectively. The calibration curves were linear within the range of $0.1{\sim}32{\mu}g/mL$ with the square of the correlation coefficient being more than 0.995. The precision (as a relative standard deviation, RSD) and accuracy (as a relative recovery) within working range were 1.3~9.1% and 84~118%, respectively.

Effect of Vanadium Addition on the Cavitation Erosion Resistance of Fe-Cr-Ni-Si-C Hardfacing Alloy (Fe-Cr-Ni-Si-C계 경면처리 합금의 Cavitation Erosion 저항성에 미치는 Vanadium 첨가의 영향)

  • 김경오;김준기;장세기;김선진;강성군
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1998.11a
    • /
    • pp.72-72
    • /
    • 1998
  • 원자력발전소 1차계통내 밸브의 경면처리(hardfa따1잉에 사용되는 재료는 $90~343^{\circ}C$의 고온과 높은 접촉응력 그리고 급격한 압력변화가 일어나는 환경에서 사용되기 때문에 내마모성과 내식성 그리고 cavitation erosion 저항성이 우수한 Co계 Stellite 합금이 현재 사용되어진다. 그러나 Co가 원력발전소 1차계통의 방사선장을 형성하는 주요 원소로 알려지면서 S Stellite 합금을 대체할 수 있는 Fe계 경면처리용 합금을 개발하려는 연구가 진행되고 있다. 현재 Fe계 경면처리용 합금의 개발은 적절환 팝금원소를 첨가하여 적충결함에너지를 낮춤 으로써 전위의 교차슬립을 억제하여 표면을 경화시키고, 소성변형을 억제하여 마모저항성을 향상시키려는 방법으로 연구가 진행되고 있다. 본 연구에서는 Fe-Cr-Ni-Si-C 합금에 Fe계 합금의 적충결함에너지를 감소시키는 것으로 알려진 vanadium을 0, 1, 2wt%첨가하여 첨가량의 변화가 cavitation erosion 저항성에 미치 는 영향을 조사하였다. Cavitation erosion 실험은 초음파를 이용하여 미세한 기포를 발생시키는 vibratory type으로 A ASTM G-32 규격에 따라 제작된 실험장치를 이용하여 $25{\pm}2^{\circ}C$의 온도의 증류수 속에 잠긴 상태에서 실시하였다. 시면은 지름 16mm, 두게 7mm의 버턴형태로 vanadium 첨가량을 변화시킨 조성을 아크 용융 방법을 이용하여 제작하였으며 hom끝단부에 부착하여 cavitation e erosion 저항성 살험을 하였다. 시편의 cavitation erosion 실험시간에 따른 무게감소량을 측 정하였으며 cavitation erosion 시킨 시편의 표면을 SEM으로 관찰하였다.겨지는 열전달 매체액 과 신규 부식억제제가 적용된 시스템 등 객관적으로 확인된 부식억제제 시스랩에 대 하여 다양한 평가 방법을 동원 비교분석하고자 하였다. 실험은 KSM 2142에 의한 무게감량법, 분극곡선 측정에 의한 $E_P$(공식개시전위), $E_R$(재부동태화전위) 측정, 시간에 따른 자연전위 변화 측정 빛 이때의 부식속도(선형분극법), 인위적인 피막 파괴 전,후 의 전위 변화 및 부식속도 측정법에 의한 국부부식 발달 저지능 등을 평가하여 각 실험결과를 비교분석하여 보았다. 수록 민감하여 304 의 IGSCC 와 매우 유사한 거동을 보인다. 본 강연에서는 304 와 600 의 고온 물에서 일어나는 IGSCC 민감도에 미치는 환경, 예민화처리, 합금원소의 영향을 고찰하고 이에 대한 최근의 연구 동향과 방식 방법을 다룬다.다.의 목적과 지식)보다 미학적 경험에 주는 영향이 큰 것으로 나타났으며, 모든 사람들에게 비슷한 미학적 경험을 발생시키는 것 이 밝혀졌다. 다시 말하면 모든 사람들은 그들의 문화적인 국적과 사회적 인 직업의 차이, 목적의 차이, 또한 환경의 의미의 차이에 상관없이 아름다 운 경관(High-beauty landscape)을 주거지나 나들이 장소로서 선호했으며, 아름답다고 평가했다. 반면에, 사람들이 갖고 있는 문화의 차이, 직업의 차 이, 목적의 차이, 그리고 환경의 의미의 차이에 따라 경관의 미학적 평가가 달라진 것으로 나타났다.corner$적 의도에 의한 경관구성의 일면을 확인할수 있지만 엄밀히 생각하여 보면 이러한 예의 경우도 최락의 총체적인 외형은 마찬가지로 $\ulcorner$순응$\lrcorner$의 범위를 벗어나지 않는다. 그렇기 때문에도 $\ulcorner$

  • PDF

Studies on Effect and its Mechanism of Herbicide Mixtures of Cyhalofop-butyl, Bispyribenzoxim and Pyrazosulfuron-ethyl - I. Interaction of Herbicide Mixture (Cyhalofop-butyl, Bispyribenzoxim 및 Pyrazosulfuron-ethyl의 상호작용효과(相互作用效果) 및 상호작용(相互作用) 기작(機作)에 관(關)하여 - 제(第) 1 보(報) 제초제간(除草劑間)의 상호작용효과(相互作用效果))

  • Wu, Ming-Gen;Kim, Kil-Ung;Shin, Dong-Hyun
    • Korean Journal of Weed Science
    • /
    • v.18 no.2
    • /
    • pp.154-160
    • /
    • 1998
  • This study was conducted to develop a foliar applied herbicide mixture covering wide spectrum weeds in dry direct seeded rice. Uniform precision central composite design(UPCCD) was employed to evaluate the effect of herbicide mixture among cyhalofop-butyl(cyhalofop), bispyribenzoxim and pyrazosulfuron-ethyl(pyrazosulfuron) having different weed control spectrum and to determine the best application rates of the three herbicide mixtures. The partial additive effect was observed in the mixture of cyhalofop and bispyribenzoxim with pyrazosulfron against Echinochloa crus-galli Beauv var crus-galli L., attributed to the negative interaction between cyhalofop and bispyribenzoxim system. Additive effect was observed in the mixture of bispyribenzoxim and pyrazosulfuron against Cyperus serotinus R. and Aneilema keisak H. but cyhalofop had no effect on these weeds. The most appropriate rate of the mixture of cyhalofop with bispyribenzoxim and pyrazosulfuron was 100 : 12 : 10g ai/ha exhibiting $ED_{90}$ against three weeds such as E. crus-galli, C. serotinus and A. keisak.

  • PDF

Determination of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THCCOOH) in human urine by solid-phase extraction and GC/MS (고체상 추출과 GC/MS를 이용한 소변 중 대마 대사체 (THCCOOH) 분석)

  • Cheong, Jae Chul;Kim, Jin Young;In, Moon Kyo;Cheong, Won Jo
    • Analytical Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.441-448
    • /
    • 2006
  • 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THCCOOH) is the major metabolite of tetrahydrocannabinol (THC) which is the primary psychoactive component of marijuana. It is also the target analyte for the discrimination marijuana use. A method using solid-phase extraction (SPE) and gas chromatography/mass spectrometry (GC/MS) was developed for the determination of THCCOOH in human urine. Urine samples (3 mL) were extracted by SPE column with a cation exchange cartridge after basic hydrolysis. The eluents were then evaporated, derivatized, and injected into the GC/MS. The limits of detection (LOD) and quantitation (LOQ) were 0.4 and 1.2 ng/mL, respectively. The response was linear with a correlation coefficient of 0.999 within the concentration range of 1.2 (LLE 1.3)~50.0 ng/mL. The precision and accuracy were stable within 1.20% and the recovery was 83.6~90.7%. The recovery of SPE method was lower than that of liquid-liquid extraction (LLE), but there were no apparent differences in LOD, LOQ, precision and accuracy between the two methods. While SPE method is used as a very effective and rapid procedure for sample pretreatment, and clean extracts, LLE method was not suitable for the extraction procedure of THCCOOH in urine. The applicability of the method was proven by analyzing a urine samples from a marijuana abusers.

Relationship between Bronchial Sensitivity and Bronchial Reactivity in Asthma (기관지천식 환자에서 기관지 감수성과 기관지 반응성에 관한 연구)

  • Seo, Ki-Youl;Chang, Jung-Hyun;Cheon, Seon-Hee
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.341-350
    • /
    • 1998
  • Background: Airway hyperreponsiveness is a cardinal feature of asthma. It consists of both an increased sensitivity of the airways, as indicated by a smaller concentration of a constrictor agonist needed to initiate the brochoconstrictor response and an increased reactivity, increments in response induced subsequent doses of constrictor, as manifested by slopes of the dose-response curve. The purpose of this study is to observe the relationship between bronchial sensitivity and reactivity in asthmatic subjects. Method: Inhalation dose-response curves using methacholine were plotted in 56 asthmatic subjects. They were divided into three groups(mild, moderate and severe) according to clinical severity of bronchial asthma. PC20 were determined from the dose-response curve as the provocative concentration of the agonist causing a 20% fall in FEVl. PC40 were presumed or determined from the dose response curve, using the PC20 and the one more dose after PC20. Reactivity was calculated from the dose-response curve regression line, connecting PC20 with PC40. Results: PC20 were 1.83mg/ml in mild group, 0.96mg/ml in moderate, and 0.34mg/ml in severe. PC40 were 7.l7mg/ml in mild group, 2.34mg/ml in moderate, and 0.75mg/ml in severe. Reactivity were $24.7{\pm}17.06$ in mild group, $46.1{\pm}22.l0$ in moderate, and $59.0{\pm}5.82$ in severe. There was significant negative correlation between PC20 and reactivity (r= -0.70, P<0.01). Conclusion: Accordingly, there was significant negative correlation between bronchial sensitivity and brochial reactivity in asthmatic subjects. However, in some cases, there were wide variations in terms of the reactivity among the subjects who have similar sensitivity. So both should be assessed when the bronchial response tor bronchoconstrictor agonists is measured.

  • PDF

A Robust Design of Response Surface Methods (반응표면방법론에서의 강건한 실험계획)

  • 임용빈;오만숙
    • The Korean Journal of Applied Statistics
    • /
    • v.15 no.2
    • /
    • pp.395-403
    • /
    • 2002
  • In the third phase of the response surface methods, the first-order model is assumed and the curvature of the response surface is checked with a fractional factorial design augmented by centre runs. We further assume that a true model is a quadratic polynomial. To choose an optimal design, Box and Draper(1959) suggested the use of an average mean squared error (AMSE), an average of MSE of y(x) over the region of interest R. The AMSE can be partitioned into the average prediction variance (APV) and average squared bias (ASB). Since AMSE is a function of design moments, region moments and a standardized vector of parameters, it is not possible to select the design that minimizes AMSE. As a practical alternative, Box and Draper(1959) proposed minimum bias design which minimize ASB and showed that factorial design points are shrunk toward the origin for a minimum bias design. In this paper we propose a robust AMSE design which maximizes the minimum efficiency of the design with respect to a standardized vector of parameters.

CFD Analysis of EFD-CFD Workshop Case 3 using Commercial and Open Source CFD codes (상용 및 오픈소스 CFD 코드를 이용한 EFD-CFD 워크샵 Case 3 해석)

  • Kim, Jong Rok
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.45 no.3
    • /
    • pp.241-251
    • /
    • 2017
  • Computational fluid dynamics analysis was performed for the case 3 of the EFD-CFD workshop. Solvers were used for three commercial CFD codes(Star-CCM+, Fluent and CFX) and an open source CFD code(SU2). The grid were generated four types depending on the total cells using commercial grid generation code(Pointwise). Mach number of 0.4 and 0.8, 2 degree angle of attack and Mach number of 0.9, 1 degree angle of attack were calculated. Similar pressure coefficient curve and normal force coefficient were showed from the coarse grid to fine grid of four codes. But there is a difference in the drag coefficient. The position of the shock wave was predicted forward as the discretization order increased in calculations using Star-CCM+ and Fluent. The computation time to converge, Fluent, Star-CCM +, CFX are in order, and SU2 takes much time to converge.