Browse > Article
http://dx.doi.org/10.5012/jkcs.2012.56.5.583

Simultaneous Analysis of Pesticides in Aqueous Sample by HF-LPME  

Nam, Jang-Woo (Department of Chemistry, Kyonggi University)
Lee, Kang-Jin (WoongJin Coway R&D Center)
Myung, Seung-Woon (Department of Chemistry, Kyonggi University)
Publication Information
Abstract
The HF (Hollow fiber) extraction method was optimized to analysis seven species of pesticides in aqueous sample and analyzing samples by GC/MS. Hollow fiber extraction showed good efficiency when it was conducted under these conditions: organic solvent was toluene and agitation speed was 1200 rpm. The 15% concentration of NaCl was optimized when it was experimented between 5% and 25%. The equilibrium time was determined at 15 minutes. The pH 5 showed the best effect on the extraction efficiency. The linearities of calibration curves of seven species were good with correlation of regression ($r^2$) over 0.995 when they were experimented over a concentration range of $5{\mu}g/L$ to $50{\mu}g/L$. The analytical data exhibited the detection of limits (LODs) range of $0.37{\mu}g/L$ to $1.23{\mu}g/L$ and the limit of quantification (LOQs) range of $1.19{\mu}g/L$ to $3.91{\mu}g/L$. The optimized HF-LPME extraction method provides a simple and effective preparation and requires small amount of organic solvents and samples compared to conventional pre-treatment methods.
Keywords
Pesticides; HF-LPME; GC/MS;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Zhu, L.; Ee, K. H.; Zhao, L.; Lee, H. K. J. Chromatogr., A 2002, 963, 335.   DOI
2 Barahona, F.; Gjelstad, A.; Bjergaard, S. P.; Rasmussen, K. E. J. Chromatogr., A 2010, 1217, 1989.   DOI   ScienceOn
3 Bedendo, G.C.; Carasek, E. J. Chromatogr., A 2010, 1217, 7.   DOI
4 Gonzalez-Peas, E.; Leache, C.; Viscarret, M.; Perez de Obanos, A.; Araguas, C.; Lopez de Cerain, A. J. Chromatogr., A 2004, 1025, 163.   DOI
5 Shrivas, K.; Patel, D. K. Food Chem. 2011, 124, 1673.   DOI   ScienceOn
6 Sun, X.; Zhu, F.; Xi, J.; Lu, T.; Liu, H.; Tong, Y.; Ouyang, G. Mar. Pollut. Bull. 2011, 63, 102.   DOI
7 Pinto, M.I.; Sontag, G.; Bemardino, R. J.; Noronha, J. P. Microchem. J. 2010, 96, 225.   DOI
8 Asensio-Ramos, M.; Ravelo-Perez, L. M.; Gonzalez-Curbelo, M. A. J. Chromatogr., A 2011, 1218, 7415.   DOI
9 Lambropoulou, D. A.; Albanis, T. A. J. Chromatogr., A 2005, 1072, 55.   DOI   ScienceOn
10 Hu, Y.; Wang, Y.; Hu, Y.; Li, G. J. Chromatogr., A 2009, 1216, 8304.   DOI
11 Huang, S.-P.; Huang, S.-D. J. Chromatogr., A 2006, 1135, 6.   DOI
12 Magdic, S.; Pawliszyn, J. B. J. Chromatogr., A 1996, 723, 111.   DOI
13 Aguilar, C.; Penalver, S.; Pocurull, E.; Borrull, F.; Marce, R. M. J. Chromatogr., A 1998, 795, 105.   DOI
14 Basheer, C.; Balasubramanian, R.; Lee, H. K. J. Chromatogr., A, 2003, 1016, 11.   DOI
15 Hou, L.; Shen, G.; Lee, H. K. J. Chromatogr., A, 2003, 985, 107.   DOI
16 Basheer, C.; Suresh, V.; Renu, R.; Lee, H. K. J. Chromatogr., A 2004, 1033, 213.   DOI
17 Zhang, J.; Lee, H. K. J. Chromatogr., A 2006, 1117, 31.   DOI
18 Zhao, L.; Lee, H. K. J. Chromatogr., A 2001, 919, 381.   DOI
19 Zhao, L.; Lee, H. K. J. Chromatogr., A 2004, 1038, 37.   DOI
20 In, C.-I; Kim, T.-J; Myung, S.-W. Aanal. Sci. & Tech. 2008, 21, 84.
21 Lambropoulou, D. A.; Albanis, T. A. J. Chromatogr., A 2004, 1061, 11.   DOI
22 Xiong, J.; Hu, B. J. Chromatogr., A 2008, 1193, 7.   DOI
23 Valor, J.; Lee, H. K. J. Chromatogr., A 1997, 767, 195.   DOI
24 Lambropoulou, D. A.; Albanis, T. A. J. Biochem. Biophys. Methods 2007, 70, 195.   DOI   ScienceOn
25 Basheer, C.; Obbard, J. P.; Lee, H. K. J. Chromatogr., A 2005, 1068, 221.   DOI
26 Basheer, C.; Lee, H. K.; Obbard, J. P. J. Chromatogr., A 2002, 968, 191.   DOI
27 Xiong, J.; Hu, B, J. Chromatogr. A 2008, 1193, 7.   DOI
28 Mahara, B. M.; Borossay, J.; Torkos, K. Microchem. J. 1998, 58, 31.   DOI   ScienceOn
29 Balinova, A. J. Chromatogr. A, 1996, 754, 125.   DOI