• 제목/요약/키워드: Quasi-static

검색결과 908건 처리시간 0.022초

철도차량의 충돌 시뮬레이션을 위한 유압 완충기의 특성 맵 (Characteristic Map of Hydraulic Buffer for Collision Simulation of Rolling Stock)

  • 김진성;최정흠;박영일
    • 한국안전학회지
    • /
    • 제31권1호
    • /
    • pp.41-47
    • /
    • 2016
  • The rolling stock is composed of several cars. In order to operate in combination, it is necessary to connect the device, called coupler, between the rolling stocks. When the collision occurs between cars, couplers should be able to absorb the shock. Urban railway has used only rubber absorbers. But recently, the hydraulic buffer has been considered in general railway. In order to know the performance of the buffer it should be conducted to experiments. But whenever this combination change, we should experiments to know a lot of the dynamic behavior of each coupler. These experiments are generally replaced by the simulation, since a lot of time and cost consuming. The quasi-static map of hydraulic buffer obtained by the experiments is required for the simulation. However, the experiments for obtaining such a quasi-static map is costly and time consuming. In this paper, it proposes a method for deriving the quasi-static map of hydraulic buffer from the theoretical model.

발포 EPP/EPS의 충격특성에 관한 실험적 연구 (Experimental Study for the Impact Characteristics of Expanded EPP/EPS Foams)

  • 김한국;김병준;정광영;전성식
    • Composites Research
    • /
    • 제26권6호
    • /
    • pp.343-348
    • /
    • 2013
  • 본 연구에서는 발포 폴리프로필렌(Expanded polypropylene)과 발포 폴리스티렌(Expanded polystyrene)의 준정적 시험(Quasi-static test) 및 계장화 충격 시험(Instrumented impact test)을 수행하였다. EPP와 EPS는 4가지의 다른 밀도에 대해 원통형 시편이 준비되었다. 준정적 시험에는 MTS 858을 사용하여 0.001 $s^{-1}$과 0.1 $s^{-1}$ 두 가지 변형률속도 조건으로 진행되어 결과를 분석하였다. 계장화 충격 시험에서는 Instron dynatup 9250HV를 사용하여, 각각 100 J, 200 J, 300 J의 서로 다른 충격에너지를 가했을 때의 응력-변형률 선도 결과를 비교 분석하였다.

강합성교각의 내진성능평가 Part II: 유사동적실험 및 잔류내진성능 평가 (Seismic Performance of Concrete-Filled Steel Piers Part II: Pseudo-Dynamic Test and Residual Seismic Capacity)

  • 조창빈;서진환;장승필
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.21-28
    • /
    • 2002
  • Ductile behavior and strength of concrete-filled steel(CFS) piers was supported by many quasi-static cyclic loading tests. This test method, however, only estimates the member′s deformation capacity under escalating and repetitive displacement and ignores dynamic and random aspects of an earthquake load. Therefore, to understand complete seismic behavior of the structure against an earthquake, dynamic tests such as shaking table test and pseudo-dynamic tests are required as well as quasi-static tests. In this paper, following "Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loadint Test", the seismic behavior of CFS and steel piers designed for I-Soo overpass in Seoul in investigated by the pseudo-dynamic test. In addition, the residual strength of both piers after an earthquake is estimated by the quasi-static test. The results show that both piers have satisfactory ductility and strength against well-known EI Centro earthquake although the CFS pier has better strength and energy dissipation than the steel pier.

NQS효과를 고려한 FD-SOI MOSFET의 고주파 소신호 모델변수 추출방법 (Accurate parameter extraction method for FD-SOI MOSFETs RF small-signal model including non-quasi-static effects)

  • 김규철
    • 한국정보통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.1910-1915
    • /
    • 2007
  • 본 논문에서는 NQS(non-quasi-static)효과를 고려한 FD(fully depleted)-SOI(silicon-on-insulator) MOSFETs의 고주파 소신호 모델링을 위한 등가회로 변수들을 간단하고 정확히 추출하는 방법을 제시하였다. 제시된 추출방법은 임피던스와 어드미턴스 행렬계산으로 S-파라미터의 측정 결과로부터 MOSFET의 외부 기생용량과 기생저항을 제거하여 물리적인 특성을 바탕으로 한 MOSFET의 내부등가회로변수가 간단히 추출되어진다. 제시된 방법으로 등가 회로를 구한 후 Y-파라미터를 계산하여 측정치와 비교한 결과 500MHz부터 200Hz까지 잘 일치함을 확인하였다.

금속 성형 공정의 준정적 변형 예측을 위한 외연적 시간 적분 유한 요소법의 적용에 대한 연구 (Application of the explicit time integration finite element method to quasi-static metal forming problems)

  • 유요한;양동열
    • 한국정밀공학회지
    • /
    • 제12권12호
    • /
    • pp.53-63
    • /
    • 1995
  • In the analysis of metal forming problems, the explicit time integration finite element method, which does not have convergence problems, is frequently used. The present work is to assess the applicability of the explicit time integration finite element method to quasi-static metal forming problems. Compressing analyses of thin-walled tubes and solid cylinders are performed with different loading velocities. The computed buckled profiles of thin walled tubes are compared with the theoretical and experimental ones and it is found that at sufficiently low loading velocity, the explicit time integration finite element method accurately predict quasi-static buckled profiles. When loading volocity is increased, the computed buckled profiles of thin-walled tubes are very sensitive to loading velocity however the computed profiles of solid cylinders are less sensitive to loading velocity. In orther words, the geometrically self-constrained specimens like solid cylinders are less sensitive to loading velocity than the geometrically unconstrained specimens like thin-walled tubes. As a result, it is found that the geometrically self-constrained problems which include the greater part of metal forming problems can be efficiently analyzed with loading velocity control technique.

  • PDF

An Experimental Study on the Axial Collapse Characteristics of Hat and Double Hat Shaped Section Members at Various Velocities

  • Cha, Cheon-Seok;Chung, Jin-Oh;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.924-932
    • /
    • 2004
  • In this study, the axial collapse tests were performed under either static (or quasi-static) or impact loads with several collapse velocities based on the expectation that para-closed sections of the front-end side members (spot welded hat and double hat shaped section members) would show quite different collapse characteristics from those for seamless section. The test results showed that both of the hat and double hat shaped section members failed in the stable sequential collapse mode in the static or quasi-static collapse tests, while the double hat shaped section members underwent the unstable collapse mode especially when the impact velocity is high. The mean collapse loads in the hat shaped section members increase with collapse velocity for all the cases of the static, quasi-static, and impact collapse tests. In the double hat shaped section members, however, the mean collapse loads decrease with increase in collapse velocity in the impact tests.

복합재료 적층판의 정 강도 해석 및 실험 (The Static Strength Analysis and Experiment of Composite Laminate)

  • 김인권;공창덕;방조혁
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2001년도 제16회 학술발표회 논문초록집
    • /
    • pp.104-107
    • /
    • 2001
  • The purpose of this work is to investigate the static strength, the stress distribution, and the failure process of quasi-isotropic composite laminates made of two different matrices when loading directions are changed. We carried out static tests of $[0/-60/+60]_s$ and $[+30/-30/90]_s$ laminates. Two types of matrices used are AS4/epoxy and AS4/PEEK. The damage mechanisms of the quasi-isotropic laminate, $[0/-60/+60]_s$, strongly depend on the load direction applied to the laminate.

  • PDF

중간주파수 대역에서 준정적(Quasi-Static) FDTD 기법을 이용한 인체 유도전류 분석 (Analysis of Body Induced Current in Middle Frequency Range Using Quasi-Static FDTD)

  • 변진규
    • 조명전기설비학회논문지
    • /
    • 제23권1호
    • /
    • pp.141-149
    • /
    • 2009
  • 본 논문에서는 준정적 FDTD 기법을 FORTRAN 프로그래밍을 통해 직접 구현하고 이를 이용해 중간주파수 대역의 인체유도전류 분포를 해석하였다. 제작된 프로그램의 타당성을 검증하기 위하여 기존 FDTD 기법을 적용하기 어려운 테스트 모델에 대한 계산결과를 이론적 해와 비교하고, 타임스텝이 크게($5.68{\times}10^6$배) 단축되는 것을 확인하였다. 검증된 수치해석 기법을 이용하여 20[kHz] 자기장과 1[MHz] 전기장에 노출된 3차원 고해상도 인체모델에 유기되는 유도전류의 분포를 계산하고, 양 발의 접지조건이 유도전류의 분포와 크기에 미치는 영향을 분석하였다. 본 연구는 인체유도전류의 안전성 평가, 생체전기 응용 진단장치 개발 등을 포함한 다양한 분야에서 활용될 것으로 기대된다.

액상가압공정으로 제조된 STS304와 Ta 섬유 강화 Zr계 비정질 복합재료의 준정적 및 동적 변형거동 (Quasi-Static and Dynamic Deformation Behavior of STS304- and Ta-fiber-reinforced Zr-based Amorphous Matrix Composites Fabricated by Liquid Pressing Process)

  • 김용진;신상용;김진성;허훈;김기종;이성학
    • 대한금속재료학회지
    • /
    • 제48권6호
    • /
    • pp.477-488
    • /
    • 2010
  • Zr-based amorphous alloy matrix composites reinforced with stainless steel (STS) and tantalum continuous fibers were fabricated without pores or defects by a liquid pressing process, and their quasi-static and dynamic deformation behaviors were investigated by using a universal testing machine and a Split Hopkinson pressure bar, respectively. The quasi-static compressive test results indicated that the fiberreinforced composites showed amaximum strength of about 1050~1300 MPa, and its strength maintained over 700 MPa until reaching astrain of 40%. Under dynamic loading, the maximum stresses of the composites were considerably higher than those under quasi-static loading because of the strain-rate hardening effect, whereas the fracture strains were considerably lower than those under quasi-static loading because of the decreased resistance to fracture. The STS-fiber-reinforced composite showed a greater compressive strength and ductility under dynamic loading than the tantalum-fiber-reinforced composite because of the excellent resistance to fracture of STS fibers.

An evaluation of iced bridge hanger vibrations through wind tunnel testing and quasi-steady theory

  • Gjelstrup, H.;Georgakis, C.T.;Larsen, A.
    • Wind and Structures
    • /
    • 제15권5호
    • /
    • pp.385-407
    • /
    • 2012
  • Bridge hanger vibrations have been reported under icy conditions. In this paper, the results from a series of static and dynamic wind tunnel tests on a circular cylinder representing a bridge hanger with simulated thin ice accretions are presented. The experiments focus on ice accretions produced for wind perpendicular to the cylinder at velocities below 30 m/s and for temperatures between $-5^{\circ}C$ and $-1^{\circ}C$. Aerodynamic drag, lift and moment coefficients are obtained from the static tests, whilst mean and fluctuating responses are obtained from the dynamic tests. The influence of varying surface roughness is also examined. The static force coefficients are used to predict parameter regions where aerodynamic instability of the iced bridge hanger might be expected to occur, through use of an adapted theoretical 3-DOF quasi-steady galloping instability model, which accounts for sectional axial rotation. A comparison between the 3-DOF model and the instabilities found through two degree-of-freedom (2-DOF) dynamic tests is presented. It is shown that, although there is good agreement between the instabilities found through use of the quasi-steady theory and the dynamic tests, discrepancies exist-indicating the possible inability of quasi-steady theory to fully predict these vibrational instabilities.