• Title/Summary/Keyword: Quantification Method

Search Result 1,493, Processing Time 0.035 seconds

Simultaneous Determination of Penicillin Antibiotics in Meat using Liquid Chromatography Tandem Mass Spectrometry (LC-MS/MS를 이용한 육류 중 페니실린계 항생제 8종의 동시분석 및 적용성 검증)

  • Kim, Myeong-Ae;Yoon, Su-Jin;Kim, MeeKyung;Cho, Yoon-Jae;Choi, Sun-Ju;Chang, Moon-Ik;Lee, Sang-Mok;Kim, Hee-Jeong;Jeong, Jiyoon;Rhee, Gyu-Seek;Lee, Sang-Jae
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.2
    • /
    • pp.131-140
    • /
    • 2014
  • The objective of this study was to develop a simultaneous method of 8 penicillin antibiotics including amoxicillin, ampicillin, cloxacillin, dicloxacillin, nafcillin, oxacillin, penicillin G and penicillin V in meat using LC-MS/MS. The procedure involves solid phase extraction with HLB cartridge and subsequent analysis by LC-MS/MS. To optimize MS analytical condition of 8 compounds, each parameter was established by multiple reaction monitoring in positive ion mode. The chromatographic separation was achieved on a $C_{18}$ column with a mobile phase of 0.05% formic acid and 0.05% formic acid in acetonitrile at a flow rate of 0.2 mL/min for 20 min with a gradient elution. The developed method was validated for specificity, linearity, accuracy and precision in beef, pork and chicken. The recoveries were 71.0~106%, and relative standard deviations (RSD) were 4.0~11.2%. The limit of detection (LOD) and the limit of quantification (LOQ) were 0.003~0.008 mg/kg and 0.01~0.03 mg/kg, respectively, that are below maximum residue limit (MRL) of the penicillins. This study also performed survey of residual penicillin antibiotics for 193 samples of beef, pork and chicken collected from 9 cities in Korea. Penicillins were not found in all the samples except a sample of pork which contained cloxacillin (concentration of 0.08 mg/kg) below the MRL (0.3 mg/kg).

1H Solid-state NMR Methodology Study for the Quantification of Water Content of Amorphous Silica Nanoparticles Depending on Relative Humidity (상대습도에 따른 비정질 규산염 나노입자의 함수량 정량 분석을 위한 1H 고상 핵자기 공명 분광분석 방법론 연구)

  • Oh, Sol Bi;Kim, Hyun Na
    • Korean Journal of Mineralogy and Petrology
    • /
    • v.34 no.1
    • /
    • pp.31-40
    • /
    • 2021
  • The hydrogen in nominally anhydrous mineral is known to be associated with lattice defects, but it also can exist in the form of water and hydroxyl groups on the large surface of the nanoscale particles. In this study, we investigate the effectiveness of 1H solid-state nuclear magnetic resonance (NMR) spectroscopy as a robust experimental method to quantify the hydrogen atomic environments of amorphous silica nanoparticles with varying relative humidity. Amorphous silica nanoparticles were packed into NMR rotors in a temperature-humidity controlled glove box, then stored in different atmospheric conditions with 25% and 70% relative humidity for 2~10 days until 1H NMR experiments, and a slight difference was observed in 1H NMR spectra. These results indicate that amount of hydrous species in the sample packed in the NMR rotor is rarely changed by the external atmosphere. The amount of hydrogen atom, especially the amount of physisorbed water may vary in the range of ~10% due to the temporal and spatial inhomogeneity of relative humidity in the glove box. The quantitative analysis of 1H NMR spectra shows that the amount of hydrogen atom in amorphous silica nanoparticles linearly increases as the relative humidity increases. These results imply that the sample sealing capability of the NMR rotor is sufficient to preserve the hydrous environments of samples, and is suitable for the quantitative measurement of water content of ultrafine nominally anhydrous minerals depending on the atmospheric relative humidity. We expect that 1H solid-state NMR method is suitable to investigate systematically the effect of surface area and crystallinity on the water content of diverse nano-sized nominally anhydrous minerals with varying relative humidity.

Development of Analytical Method for Detection of Fungicide Validamycin A Residues in Agricultural Products Using LC-MS/MS (LC-MS/MS를 이용한 농산물 중 살균제 Validamycin A의 시험법 개발)

  • Park, Ji-Su;Do, Jung-Ah;Lee, Han Sol;Park, Shin-min;Cho, Sung Min;Shin, Hye-Sun;Jang, Dong Eun;Cho, Myong-Shik;Jung, Yong-hyun;Lee, Kangbong
    • Journal of Food Hygiene and Safety
    • /
    • v.34 no.1
    • /
    • pp.22-29
    • /
    • 2019
  • Validamycin A is an aminoglycoside fungicide produced by Streptomyces hygroscopicus that inhibits trehalase. The purpose of this study was to develop a method for detecting validamycin A in agricultural samples to establish MRL values for use in Korea. The validamycin A residues in samples were extracted using methanol/water (50/50, v/v) and purified with a hydrophilic-lipophilic balance (HLB) cartridges. The analyte was quantified and confirmed by liquid chromatograph-tandem mass spectrometer (LC-MS/MS) in positive ion mode using multiple reaction monitoring (MRM). Matrix-matched calibration curves were linear over the calibration ranges (0.005~0.5 ng) into a blank extract with $R^2$ > 0.99. The limits of detection and quantification were 0.005 and 0.01 mg/kg, respectively. For validation validamycin A, recovery studies were carried out three different concentration levels (LOQ, $LOQ{\times}10$, $LOQ{\times}50$, n = 5) with five replicates at each level. The average recovery range was from 72.5~118.3%, with relative standard deviation (RSD) less than 10.3%. All values were consistent with the criteria ranges requested in the Codex guidelines (CAC/GL 40-1993, 2003) and the NIFDS (National Institute of Food and Drug Safety) guideline (2016). Therefore, the proposed analytical method is accurate, effective and sensitive for validamycin A determination in agricultural commodities.

Study on Effective Preservation of Bovine Pericardium Using Decellulariation and ${\alpha}$-galactosidase for Eliminating Xenoreactive Antigen (이종 항원 제거를 위한 무세포화와 알파-갈락토시다아제를 이용한 효과적인 우심낭 보존 방법에 관한 연구)

  • Kim, Min-Seok;Park, Cham-Jin;Kim, Soo-Hwan;Lim, Hong-Gook;Kim, Yong-Jin
    • Journal of Chest Surgery
    • /
    • v.43 no.6
    • /
    • pp.576-587
    • /
    • 2010
  • Background: Effective decellularization and fixation process is critical, in order to use xenogenic valves clinically. In the present study, we decellularized bovine pericardium using sodium dodecyl sulfate (SDS) and N-lauroyl sarcosinate, treated with $\alpha$-galactosidase, and then fixed in various manners, to find out the most effective tissue preservation & fixation procedure. Material and Method: Bovine pericardium was decellularized with SDS and N-lauroyl sarcosinate, and treated with $\alpha$-galactosidase. Both groups were fixed differently, by varying glutaraldehyde (GA) or EDC (1-ethyl-3-(3-dimethyl aminopropyl)-carbodiimide)/N-hydroxysuccinamide (NHS) treatment conditions. Thereafter, physical examination, tensile strength test, thermal stability test, cytotoxicity test, pronase test, pronase-ninhydrin test, purpald test, permeability test, compliance test, H&E staining, DNA quantification, and $\alpha$-galactose staining were carried out to each groups. Result: GA fixed groups showed better physical properties and thermal stability than EDC/NHS fixed groups, EDC/NHS-GA dual fixed groups showed better physical properties and thermal stability than EDC/NHS fixed groups, and showed better thermal stability than GA fixed groups. In pronase test and pronase-ninhydrin test, GA fixed groups and EDC/NHS-GA dual fixed groups showed stronger crosslinks than EDC/NHS groups. Permeability and compliance tended to increase in EDC/NHS-GA dual fixed groups, compared to GA fixed groups. But, EDC/NHS-GA dual fixed groups had stronger tensile strength and lower cytotoxicity than GA fixed groups. Conclusion: We have verified that EDC/NHS-GA dual fixation can make effective crosslinks and lower the toxicity of GA fixation. Henceforth, we will verify if EDC/NHS-GA dual fixation can lower calcifications & tissue failure in vivo experiment.

Analysis of ethyl glucuronide (EtG) in Hair for the diagnosis of chronic alcohol abuse of Korean (한국인의 만성 알코올 중독 진단을 위한 모발에서 Ethyl Glucuronide (EtG) 분석법 연구)

  • Gong, Bokyoung;Jo, Young-Hoon;Ju, Soyeong;Min, Ji-Sook;Kwon, Mia
    • Analytical Science and Technology
    • /
    • v.33 no.3
    • /
    • pp.151-158
    • /
    • 2020
  • Alcohol, which can easily be obtained in the same way as ordinary beverages, is harmful enough to cause death due to excessive drinking and chronic alcohol intake, so it is important to maintain a proper amount of drinking and healthy drinking habits. In addition, the incidence of behavioral disturbances and impaired judgments that can be caused by chronic alcohol drinking of more than adequate amounts of alcohol is also significant. Accordingly it is very useful for forensic science to check whether the person involved is drunken or is alcoholism state in various accidents. Currently, in Korea, alcohol consumption is determined by detecting the level of alcohol or alcohol metabolism 'ethyl glucuronide (EtG)' in blood or urine samples. However, analysis of alcohol or EtG in blood or urine can only provide information about the current state of alcohol consumption because of a narrow window of detection time. Therefore, it is important to analyze the EtG as a long-term direct alcohol metabolite bio-marker in human hair and to investigate relationship between alcohol consumption and EtG concentration for the evaluation of chronic ethanol consumption. In this study, we established an analytical method for the detection of EtG in Korean hair efficiently and validated selectivity, linearity, limits of detection (LOD), limits of quantification (LOQ), matrix effect, recovery, process efficiency, accuracy and precision using liquid chromatography tandem mass spectrometry (LC-MS/MS). In addition, the assay performance was evaluated in Korean social drinker's hair and the postmortem hair of a chronic alcoholism. The results of this study can be useful in monitoring the alcohol abuse of Korean in clinical cases and legal procedures related to custody and provide a useful tool to evaluate postmortem diagnosis of alcoholic ketoacidosis in forensics.

Studies on Simultaneous Determination of Chlorophyll a and b, Pheophorbide a, and $\beta-Carotene$ in Chlorella and Spirulina Products (클로렐라 및 스피루리나제품에 함유된 엽록소 a, b, 페오포르바이드 a 및 $\beta$-카로틴의 동시분석법에 관한 연구)

  • Lee Young Ja;Kim So Hee;Kim Jin-Sook;Han Jeong A;Seo Hae Jeom;Lim Hyo Jeong;Choi Soo Young
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2005
  • A simple and sensitive analysis method based on reverse phase (RP) HPLC with UV detector was developed for simultaneous determination of chlorophyll a and b, pheophorbide a and $\beta-Carotene$ in Chlorella and Spirulina products. For added concentration $(50\;\mug/ml)$ of chlorophyll a and b, pheophorbide a and $\beta-Carotene$, recoveries of those were 70.3, 71.6, 60.1 and $90.5\%$, respectively, with relative standard deviations of 2.8,6.0, 10.6 and $10.4\%$. Limit of detection and quantification had ranges of $0.1\sim1.0\;\mug/ml$ and $0.2\sim2.0\;\mug/ml$, respectively. Calibration curve was linear with correlation coefficient of 0.995 for chlorophyll a and b, pheophorbide a and $\beta-Carotene$. Results of simultaneous determination in Chlorella and Spirulina products were showed ranges of $121.g\sim543.0\;\mug/ml$ for chlorophyll a,$0.6\sim160.0\;\mug/ml$ for chlorophyll b, $19.2\sim60.3\;\mug/ml$ for pheophorbide a and $383.6\sim1713.7\;\mug/ml$ for $\beta-Carotene$, respectively. Chlorophyll b contents in Chlorella products were detected above 30 times level to those in Spirulina products. $\beta-Carotene$ contents in Spirulina products were detected 2.7 times level to those in Chlorella products.

Residual characteristic of tebuconazole and fludioxonil in Allium victorialis (Allium ochotense Prokh.) (소면적 재배작물 산마늘(Allium ochotense Prokh.) 중 살균제 Tebuconazole 및 Fludioxonil의 잔류특성)

  • Woo, Min-Ji;Hur, Kyung-Jin;Kim, Ji-Yoon;Saravanan, Manoharan;Kim, Se-Weon;Hur, Jang-Hyeon
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.354-360
    • /
    • 2015
  • In recent years, Allium victorialis has been extensively used as a pharmacological agent for various diseases in the form of anti-arteriosclerotic, anti-diabetic and anti-cancer. Allium victorialis is severely affected by various fungal diseases since it naturally grow in the shady and humid environments in Korea. In this case, different types of fungicides are applied to control the fungal diseases in Allium victorialis. The present study was aimed to determine the residual characteristics of two fungicides namely tebuconazole and fludioxonil on Allium victorialis. For this study, the fungicides were drenched soil on Allium victorialis in the cultivation area Pyeongchang by the standard (two thousand fold) and double (thousand fold) dilutions. At the end of $15^{th}$, $30^{th}$ and $40^{th}$ days samples were collected for residue analysis. Residues of tebuconazole and fludioxonil were analyzed using GC/NPD (Gas Chromatography/Nitrogen Phosphorus Detector) and their recovery were found to be 108.8~119.5% and 91.3~104.8%, respectively. The method of limits of quantification for both fungicides was $0.01mg\;kg^{-1}$. Further, the results of this study shows that the residue levels of both fungicides on Allium victorialis were <$0.01{\sim}0.12mg\;kg^{-1}$ and $0.01{\sim}0.09mg\;kg^{-1}$ and their % ADI (% Acceptable Daily Intake) were 17.44% and 25.75%, respectively. Based on the results obtained in this study, we suggest that the residue levels of both of the fungicides on Allium victorialis are safe and these fungicides can also be used to control fungal diseases in Allium victorialis.

Varietal Analysis and Quantification of Resveratrol in Mulberry Fruits (뽕나무 계통별 오디의 레스베라트롤 함량 분석)

  • Kim Hyun-Bok;Kim Jung-Bong;Kim Sun-Lim
    • Journal of Sericultural and Entomological Science
    • /
    • v.47 no.2
    • /
    • pp.51-55
    • /
    • 2005
  • Resveratrol is naturally occurring phytoalexin compounds produced by grape berries, peanuts, and their products in response to stress such as fungal infection, heavy metal ions or UV irradiation. The objective of this study was to develope a reliable high performance liquid chromatographic (HPLC) method for the quantitative determination of trans-resveratrol in mulberry fruit. Samples were extracted in 80% MeOH and filtered with $0.45{\mu}m$ syringe filter. The transresveratrol was separated Waters $C_{18}$ column, using a mobile phase containing 0.025% trifluroacetic acid in 5% acetonitril and 0.035% trifluroacetic acid in 50% acetonitril, detected by photodiode array detector (PDA) at 254 nm and the flow rate was 1ml/min. Under this analytical condition, the mean content of mulberry fruits (fifty varieties) was $777.3{\pm}585.9ppm$. Among the tested samples, 'Mansaengbaekpinosang (II)' was the highest level in 3450.6 ppm. However four accessions including 'Gukbu', 'Sabangso (I)', 'Simseol' and yield mulberry fruit were not able to detected. Eight suitable varieties selected for the production of fruit were 'Jeolgokchosaeng (Chungbuk)' 777.8 ppm, 'Dangsang 7' 771.1 ppm, 'Jangsosang' 133.9 ppm, 'Susungppong' 31.1 ppm, 'Suwonnosang' 639.7 ppm, 'Palcheongsipyung' 1475.9 ppm, 'Kangsun' 864.0 ppm, and 'Jukcheonchosaeng' 1458.5 ppm. 'Daesungppong' which was the first authorized variety for the production of mulberry fruit was 1236.7 ppm. In conclusion, these results suggest that mulberry including fruit and leaf may a good new resource for resveratrol production.

Residue Studies of Difenoconazole and Thiamethoxam during Cultivation of Sweet Persimmon for Export (수출용 단감에 대한 Difenoconazole과 Thiamethoxam의 잔류특성 연구)

  • Chang, Hee-Ra;Kang, Hae-Rim;Do, Jung-A;Oh, Jae-Ho;Hwang, In-Kyun;Kwon, Ki-Sung;Im, Moo-Hyeog;Kim, Kyun
    • Korean Journal of Environmental Agriculture
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2012
  • BACKGROUND: In order to elucidate residual characteristics of difenoconazole and thiamethoxam by treatment to sweet persimmons for one year and to generate the data for the maximum residue limit (MRL) establishment for those pesticides in or on sweet persimmon. METHODS AND RESULTS: Systemic fungicide difenoconazole WP (10% a.i.) and systemic insecticide thiamethoxam WG (10% a.i.) were sprayed onto 12~25-years-old sweet persimmons according to its preharvest interval (PHI), respectively, and then fresh sweet persimmons were harvested at 0, 1, 3, 7, 14, 21 days after treatment from pesticide-sprayed plots at each 3 sites. The analytical methods were evaluated to limit of quantification, linearity, specificity, reproducibility and recoveries. The crop samples were extracted with acetone and performed dichloromethane partition process. The extracted samples of difenoconazole were analyzed by GC-ECD and the thiamethoxam extracted samples were analyzed by HPLC with good sensitivity and selectivity of the method. The average recoveries of difenoconazole ranged from 87.5 to 99.5% with the percentage of coefficient variation in the range 4.1~7.6% at three different spiking levels(0.02, 0.2 and 2.0 mg/kg). And the average recoveries of thiamethoxam and clothianidin ranged from 88.8 to 98.9% and 83.2 to 96.6% with the percentage of coefficient variation in the range 3.6~5.0% and 3.8~9.4% at three different spiking levels(0.02, 0.2 and 2.0 mg/kg), respectively. The residue amounts ranges of difenoconazole were 0.2~0.56 mg/kg and the residue amount was decreased below the MRL level, 1.0 mg/kg, after 1 day harvest. The residue amounts ranges of thiamethoxam were 0.08~0.28 mg/kg and the residue amount was decreased below the MRL level, 0.5 mg/kg, after 1 day harvest. And the residue amount of clothianidin was below then 0.03 mg/kg for only one test site of 14 and 28 day samples. CONCLUSION: As a result, the residual amounts of difenoconazole and thiamethoxam were not exceeded the MRL of established criteria for sweet persimmon. The biological half-lives of difenoconazole and thiamethoxam were 13.6, 19.4, 16.3 and 10.0, 15.3, 14.0 days at each three test sites, respectively.

Reproducibility of Gated Myocardial Perfusion SPECT for the Assessment of Myocardial Function: Comparison with Thallium-201 and Technetium-99m-MIBI (심근 기능 측정에 사용된 게이트 심근 관류 SPECT 방법의 재현성 평가: $^{201}Tl$$^{99m}Tc$-MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Hong, Eui-Soo;Kim, Dae-Hyuk;Kim, Sung-Eun;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.5
    • /
    • pp.381-392
    • /
    • 2000
  • Purpose: We compared the reproducibility of $^{201}Tl\;and\;^{99m}Tc$-sestamibi (MIBI) gated SPECT measurement of myocardial function using the Germano algorithm Materials and Methods: Gated SPECT acquisition was repeated in the same position in 30 patients who received $^{201}Tl$ and in 26 who received $^{99m}Tc$-MIBI. The quantification of end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) on $^{201}Tl\;and\;^{99m}Tc$-MIBI gated SPECT was processed independently using Cedars quantitative gated SPECT software. The reproducibility of the assessment of myocardial function on $^{201}Tl$ gated SPECT was compared with that of $^{99m}Tc$-MIBI gated SPECT Results: Correlation between the two measurements for volumes and EF was excellent by the repeated gated SPECT studies of $^{201}Tl$ (r=0.928 to 0.986; p<0.05) and $^{99m}Tc$-MIBI (r=0.979 to 0.997; p<0.05). However, Bland Altman analysis revealed the 95% limits of agreement (2 SD) for volumes and EF were tighter by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 14.1 ml, ESV: 9.4 ml and EF: 5.5%) than by repeated $^{201}Tl$ gated SPECT (EDV: 24.1 ml, ESV: 18.6 ml and EF: 10.3%). The root mean square (RMS) values of the coefficient of variation (CV) for volumes und EFs were smaller by repeated $^{99m}Tc$-MIBI gated SPECT (EDV: 2.1 ml, ESV 2.7 ml and EF: 2.3%) than by repeated $^{201}Tl$ gated SPECT (EDV: 3.2 ml, ESV: 3.5 ml and EF: 5.2%). Conclusion: $^{99m}Tc$-MIBI provides more reproducible volumes and EF than $^{201}Tl$ on repeated acquisition gated SPECT. $^{99m}Tc$-MIBI gated SPECT is the preferable method for the clinical monitoring of myocardial function.

  • PDF