• 제목/요약/키워드: Pulse tube

검색결과 253건 처리시간 0.03초

Progress of Pulse Tube Cryocooler

  • Matsubara, Yoichi;Koh, Deuk-Yong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2010
  • The pulse tube cooler as an alternative of Stirling, G-M or VM cooler to overcome the requirement from the various application fields is described. The necessity of the object oriented cooler development is explained to realize the cryocooler of more energy-efficient, more reliable, more compact and less expensive than what is currently available commercially.

진공관 전원방식 30 W급 구리증기레이저 (A 30 W Copper Vapor Laser Using a Vacuum Tube Based Pulse Generator)

  • 진정태;차병헌;김철중;이흥호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권12호
    • /
    • pp.568-572
    • /
    • 2003
  • A longitudinal discharge heated copper vapor laser with internal diameter 28 mm and discharge length 1.3 m has been constructed and tested. At the discharging voltage 15.2 kV, pulse repetition rate 10 kHz, buffer gas pressure 40 mbar, and internal temperature of the laser plasma tube $1520^{\circ}C$, it delivers more than 30 W average laser outputs.

Experimental research on 2 stage GM-type pulse tube refrigerator for cryopump

  • Park, Seong-Je;Ko, Jun-Seok;Hong, Yong-Ju;Kim, Hyo-Bong;Yeom, Han-Kil;Koh, Deuk-Yong
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권2호
    • /
    • pp.29-33
    • /
    • 2010
  • The experimental results of the 2 stage Gifford-McMahon(GM) type pulse tube refrigerator (PTR) or cryopump are presented in this paper. The objectives of his study are to develop design technology of the integral type 2 stage PTR which rotary valve is directly connected to he hot end of the regenerator and acquire its improved performance. Design of the 2 stage PTR is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program for the design of pulse tube refrigerators. The fabricated PTR has U-type configuration and incorporates orifice valve, double-inlet valve and reservoir as phase control mechanism. Rotary valve is used to make pulsating pressure and is directly connected to inlet of $1^{st}$ stage regenerator. From experiments, cooling performance map and pressure waveform at each point were measured for different operating frequencies. Experimental results show the best cooling performance with 2 Hz operation in spite of small pressure amplitude. The lowest temperatures of the 2 stage PTR were 16.9 K at the second stage and 58.0 K at the first stage. The cooling capacities achieved were 14.4 W at 79 K, the first stage and 3.6 W at 29 K, the second stage.

심혈관계 시뮬레이터를 이용한 맥파 반사지점 추정방법들의 비교 (Evaluation of methods for estimating the pulse reflection site with cardiovascular simulator)

  • 이주연;신상훈
    • 대한한의진단학회지
    • /
    • 제19권1호
    • /
    • pp.47-54
    • /
    • 2015
  • Objective Wave reflection is an important factor that determines the shape of the pulse wave. The purpose of this study is to compare the conventional method used for estimating the reflection site of pulse with a cardiovascular simulator. Methods: In this study, cardiovascular simulator with one elastic tube was used. The pressure and flow was measured simultaneously at three different points. The measured data were used to the conventional methods to estimate the pulse wave reflection site. The results were compared with the known length which were the distances from the measured points to the end of tube. Results & Conclusions: There is a significant error with the time domain method. While, the reflection site with the frequency domain method was similar to the actual reflection site.

맥압조절이 가능한 맥파 연구용 심혈관계 시뮬레이터 개발 (Development of Cardiovascular Simulator with Control of Pulse Pressure for Pulse Wave Study)

  • 이주연;김재욱;신상훈
    • 전자공학회논문지
    • /
    • 제51권10호
    • /
    • pp.204-209
    • /
    • 2014
  • 본 논문은 맥파전달현상을 유지하며 맥압을 조절할 수 있는 시뮬레이터를 제작하는 것이 목적이다. 이를 위해 탄성튜브와 컴플라이언스 챔버를 융합하였다. 본 시뮬레이터는 슬라이더-크랭크로 구성된 압력발생부, 저항조절부를 포함한 혈관부, 수조 그리고 측정부로 구성되어있다. 챔버의 위치선정을 위해 챔버의 위치에 따른 맥파의 변화를 실험하였다. 또한 챔버가 맥압에 미치는 영향을 보기 위해 챔버의 유무에 따른 맥압의 변화를 비교하였다. 챔버의 유무가 맥파전달현상에 미치는 영향을 조사하였다. 실험결과, 튜브의 상류지점에 챔버를 설치할 때가 하류지점에 설치할 때 보다 인체와 더 유사한 압력파형을 나타냈다. 챔버를 설치하였을 때가 설치하지 않았을 때보다 인체와 유사한 맥압을 생성하였다. 챔버의 설치여부에 따른 맥파 전달 속도는 큰 변화가 없었다.

맥동관냉동기의 2차속도와 온도 (Second-order velocity and temperature in pulse tube refrigerators)

  • 이호진;채왕병;정은수
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.239-248
    • /
    • 1997
  • Steady components and unsteady components of second-order velocity and temperature within pulse tube refrigerators were obtained. Second-order solutions were obtained from the first-order solutions of continuity, momentum and energy equations, assuming that the amplitude of the piston motion is small. The axial temperature gradient was considered in the analysis. The flow direction of the streaming was consistent with previous experimental observations. Effects of axial temperature gradient on secondary flow and second-order temperature were shown.

  • PDF

4 밸브형 맥동관 냉동기의 사이클 해석 (The Cycle Analysis of 4 Valve-type Pulse Tube Refrigerator)

  • 조경철;이상원;임영헌;김수연;정평석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.636-641
    • /
    • 2001
  • In this paper, we constructed four valve type pulse tube refrigerator and found the characteristic of orifice (needle valve) opening for using phase shifter and optimum cycle time - The valve timing was controlled by the digital timers. The experimental results showed the optimum frequence and cycle time at operating conditions. The results showed that the optimum process time existed and the rate was same at each operating frequence. The no- load temperature of the refrigerator was 85K.

  • PDF

Thrust - Performance Test of Ethylene-Oxygen Single-Tube Pulse Detonation Rocket

  • Hirano, Masao;Kasahara, Jiro;Matsuo, Akiko;Endo, Takuma;Murakami, Masahide
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.205-210
    • /
    • 2004
  • The pulse detonation engine (PDE) has recently expected as a new aerospace propulsion system. The PDE system has high thermal efficiency because of its constant-volume combustion and its simple tube structure. We measured thrust of single-tube pulse detonation rocket (PDR) by two methods using the PDR-Engineering Model (full scale model) for ground testing. The first involved measuring the displacement of the PDR-EM by laser displacement meter, and the second involved measuring the time-averaged thrust by combining a load cell and a spring-damper system. From these two measurements, we obtained 130.1 N of time-averaged thrust, which corresponds to 321.2 sec of effective specific impulse (ISP). As well, we measured the heat flux in the wall of PDE tubes. The heat flux was approximately 400 ㎾/$m^2$. We constructed the PDR-Flight Mode] (PDR-FM). In the vertical flight test in a laboratory, the PDR-FM was flying and keeping its altitude almost constant during 0.3 sec.

  • PDF

관성관형 동축 맥동관 냉동기의 특성에 관한 연구 (The study of the Characteristic of the Coaxial Type Inertance Pulse Tube Refrigerators)

  • 김양훈;박성제;홍용주;김효봉;이승홍
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.33-35
    • /
    • 2003
  • There are three types that geometrical arrangement of the pulse tube and regenerator - in line type, U type, and coaxial type. The most compact and convenient one practical applications is the coaxial type. It can replace Stirling cryocooler without any change to the Dewar or the connection to the cooled devices. To investigate effects of the inertance tube, we perform experiments with varying inertance tube inner diameter and length. The experimental results show that optimum inertance tube inner diameter and length are 1.3mm, 1900mm respectively.

  • PDF

펄스 튜브를 이용한 수중 음향 성능 측정 시스템 개발 (Development of Underwater Acoustic Performance Measurement System Using Pulse Tubes)

  • 서윤호;김상렬;이성민;변양헌;서영수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 춘계학술대회 논문집
    • /
    • pp.603-608
    • /
    • 2014
  • Underwater acoustic materials are installed in order to reduce reflection, transmission and radiation of an underwater structure. The acoustic performance of the materials should be evaluated in accurately-controlled environment in terms of temperature and static pressure. In this paper, three pulse tubes, which is equipped with temperature and pressure controllers, are designed and developed to evaluate echo reduction and transmission loss for evaluating the performance below 10 kHz and 30kHz, respectively. The new procedures of the evaluation are suggested to improve the accuracy and the validation for the developed pulse tubes is carried out by comparing theoretical values to experimental ones.

  • PDF