• 제목/요약/키워드: Pulse radiation

검색결과 242건 처리시간 0.029초

방사선 검출신호의 시계열 분석에 관한 연구 (A Study on Time Series Analysis for the Detector Pulses of Radiation)

  • 홍석붕;정종은;김용균;문병수;권기호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.282-282
    • /
    • 2000
  • The analysis of the radiation effect on matter has been performed using stochastic methods. Recently, It was discovered that the detector pulses of radiation can be analysed using deterministic method that utilizes the chaotic behaviour with an attractor found in a noise region. We acquired a time series for pulse tram of Am-241 using scintillation detector and reconstructed a phase space, then performed new analysis for the radiation detection signal by applying embedding theory, Lyapunov exponent, correlation dimension, autocorrelation dimension, and power spectrum.

  • PDF

펄스 중첩 보정 스펙트럼의 라이브러리 최소자승법에의 이용 (Application of Pulse Pile-Up Correction Spectrum to the Library Least-Squares Method)

  • 이상훈
    • Journal of Radiation Protection and Research
    • /
    • 제31권4호
    • /
    • pp.173-179
    • /
    • 2006
  • 개선된 몬테칼로 코드 CEARPPU는 고계수율 상황에서의 펄스 중첩 보정 스펙트럼을 제공한다. 중성자 방사화 분석을 위하여 CEARPPU를 이용하여 보정된 스펙트럼으로 라이브러리 최소자승 동위원소 방사능 분석을 수행하여 보정하지 않은 스펙트럼을 이용하는 방법보다 우수한 결과를 얻었다.

금속펄스 선형증폭기의 빠른 입력펄스에 대한 이득안정도에 관한 연구 (Sinusoidal A Study on the gain Stability of the Feedback Linear Pulse Amplifiers for Fast Pulse Input)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제11권3호
    • /
    • pp.1-14
    • /
    • 1974
  • 귀환 펄스 선형증폭기에 단계전압과 방사능검출기에서 나오는 펄스 전압이 인가되었때 경우의 이득안정도에 관하여 해석검토 하였다. 방사능 검출기의 일부를 이루고 있는 광전증배관의 양극회로에서 형성되는 파형을 나타내는 식을 유도 하였으며 귀환 증폭기가 하나의 시정수와 두 개의 시정수를 가졌을 경우에 관하여 해석하였고 이 들을 비교 검토하였다. 이들 빠른 입력펄스전압이 귀환증폭기에 인가되면 출력전압의 선형도와 안정도는 증폭기의 rise time와, 2∼3배가 경과하여야 귀환효과가 나타난다. 이 제한을 줄이기 위하여는 귀환증폭기의 rise time을 계측할려는 입력 펄스의 폭보다 적도록 설계하여야 한다는 것을 증명하였다. 이상의 이론은 선형증폭기의 기본증폭단으로 설계된 고렬전압 귀환증폭단에도 그대로 적용굴을 보였으며 이 증폭단의 입력저항이 적을수록 이득안정도가 좋아짐을 보였다.

  • PDF

GW급 UWB용 고전압 나노초 펄스 발생 (High Voltage Nanoseconds Pulse Generation for 1GW UWB radiation)

  • 김영배;이홍식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2123-2125
    • /
    • 2005
  • Ultra wide band electromagnetic energy can be transmitted to a far field by emitting the nanoseconds high voltage Pulse electromagnetic energy via an antenna. This UWB EM energy is expected to be used in post-packing pasteurization of food, detection of buried objects or underground water veins and caves and the treatment of waste water or polluted gas. The nanoseconds pulse forming for UWB generation using 500kV blumlein line and an ultrafast switch is mentioned.

  • PDF

Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

A technique for the reduction of pulse pile-up effect in pulse-shape discrimination of organic scintillation detectors

  • Nakhostin, M.
    • Nuclear Engineering and Technology
    • /
    • 제52권2호
    • /
    • pp.360-365
    • /
    • 2020
  • A technique for the reduction of pulse pile-up effect in digital pulse-shape discrimination (PSD) of neutrons and gamma-rays with organic scintillation detectors is presented. The technique is based on an electronic reduction of the effective decay-time constant of scintillation pulses while retaining the PSD information of the pulses. The experimental results obtained with a NE213 liquid scintillation detector in a mixed radiation field of neutrons and gamma-rays are presented, demonstrating a figure of merit (FOM) of 1.20 ± 0.05 with an energy threshold of 350 keVee (electron equivalent energy) when the effective length of the pulses is reduced to 50 ns.

부귀환펄스선형증폭기의 이득 안정도에 관한 연구 (A System on the Gain Stability of Negative Feedback Pulse Linear Amplifier)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제10권5호
    • /
    • pp.7-15
    • /
    • 1973
  • 부귀환펄스선형증폭기에 단계전압과 방사능검출기에서 나오는 펄스와 같이 빠른 펄스를 인가하였을 경우의 이득 안정도에 관하여 해석하였고 실험하였다. 이들 빠른 입력전압이 부귀환증폭기에 인가되면 출력전압의 선형도와 안정도는 증폭기의 rise time의 수배가 경과하여야 부귀효과가 나타난다. 이 제한을 주리기 위하여는 부귀환증폭기의 rise time을 계측할려는 입력펄스의 폭보다 적도록 설계하여야 한다는 것을 표시하였다.

  • PDF

Hepatic Hemangiomas: Spectrum of US Appearances on Gray-scale, Power Doppler, and Contrast-Enhanced US

  • Kyoung Won Kim;Tae Kyoung Kim;Joon Koo Han;Ah Young Kim;Hyun Ju Lee;Seong Ho Park;Young Hoon Kim;Byung Ihn Choi
    • Korean Journal of Radiology
    • /
    • 제1권4호
    • /
    • pp.191-197
    • /
    • 2000
  • Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents.

  • PDF

Trichel Pulse in Negative DC Corona discharge and Its Electromagnetic Radiations

  • Zhang, Yu;Liu, Li-Juan;Miao, Jin-Song;Peng, Zu-Lin;Ouyang, Ji-Ting
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1174-1180
    • /
    • 2015
  • We investigate in this paper the radiated electromagnetic waves together with the discharge characteristics of Trichel pulse of negative DC corona discharge in air in pin-to-plate and wire-to-plate configurations. The feature of the current pulse and the frequency spectrum of the electromagnetic radiations were measured under various pressures and gas gaps. The results show that the repetition frequency and the amplitude of Trichel pulse current depend on the discharge conditions, but the rising time of the pulse relates only to the radius of needle or wire and keeps constant even if the other conditions (including the discharge current, the gas gap and the gas pressure) change. There exists the characterized spectrum of electromagnetic waves from negative corona discharge in Trichel pulse regime. These characterized radiations do not change their frequency at a given cathode geometry even if the averaged current, the gas gap or the air pressure changes, but the amplitude of radiations changes accordingly. The characterized electromagnetic radiations from Trichel pulse corona relate to the formation or the rising edge of current pulse. It confirms that the characterized radiations from Trichel pulse supply information of discharge system and provide a potential method for detecting charged targets.

Radiation detector deadtime and pile up: A review of the status of science

  • Usman, Shoaib;Patil, Amol
    • Nuclear Engineering and Technology
    • /
    • 제50권7호
    • /
    • pp.1006-1016
    • /
    • 2018
  • Since the early forties, researchers from around the world have been studying the phenomenon of deadtime in radiation detectors. Many have attempted to develop models to represent this phenomenon. Two highly idealized models; paralyzable and non-paralyzable are commonly used by most individuals involved in radiation measurements. Most put little thought about the operating conditions and applicability of these ideal models for their experimental conditions. So far, there is no general agreement on the applicability of any given model for a specific detector under specific operating conditions, let alone a universal model for all detectors and all operating conditions. Further the related problem of pile-up is often confused with the deadtime phenomenon. Much work, is needed to devise a generalized and practical solution to these related problems. Many methods have been developed to measure and compensate for the detector deadtime count loss, and many researchers have addressed deadtime and pulse pile-up. The goal of this article is to summarize the state of science of deadtime; measurement and compensation techniques as proposed by some of the most significant work on these topics and to review the deadtime correction models applicable to present day radiation detection systems.