• Title/Summary/Keyword: Pulse output

Search Result 1,166, Processing Time 0.032 seconds

Theoretical Analysis of Impact of Q-switch Rise Time on Output Pulse Performance in an Ytterbium-doped Actively Q-switched Fiber Laser (이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석)

  • Jeon, Jinwoo;Lee, Junsu;Lee, Ju Han
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.2
    • /
    • pp.58-63
    • /
    • 2013
  • A theoretical analysis of the impact of rise time of a Q-switch on the output pulse performance is carried out in an Ytterbium-doped actively Q-switched fiber laser. The finite difference time domain (FDTD) method is used to numerically simulate the Q-switched fiber laser. It is shown that stable Gaussian-like pulse shape can be generated when the Q-switch rise time is increased and pulse repetition rate is enlarged.

Phase Locked Loop based Pulse Density Modulation Scheme for the Power Control of Induction Heating Applications

  • Nagarajan, Booma;Sathi, Rama Reddy
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.65-77
    • /
    • 2015
  • Resonant converters are well suited for induction heating (IH) applications due to their advantages such as efficiency and power density. The control systems of these appliances should provide smooth and wide power control with fewer losses. In this paper, a simple phase locked loop (PLL) based variable duty cycle (VDC) pulse density modulation (PDM) power control scheme for use in class-D inverters for IH loads is proposed. This VDC PDM control method provides a wide power control range. This control scheme also achieves stable and efficient Zero-Voltage-Switching (ZVS) operation over a wide load range. Analysis and modeling of an IH load is done to perform a time domain simulation. The design and output power analysis of a class-D inverter are done for both the conventional pulse width modulation (PWM) and the proposed PLL based VDC PDM methods. The control principles of the proposed method are described in detail. The validity of the proposed control scheme is verified through MATLAB simulations. The PLL loop maintains operation closer to the resonant frequency irrespective of variations in the load parameters. The proposed control scheme provides a linear output power variation to simplify the control logic. A prototype of the class-D inverter system is implemented to validate the simulation results.

Harmonic Elimination Method of Using Coupling Transformer in Twelve Pulse Inverter (12 펄스 인버터에서 결합변압기를 이용한 고조파 제거기법)

  • Jeong, Chang-Yong;Lee, Young-Woon;Choi, Kyu-Hyoung;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.613-615
    • /
    • 1996
  • Harmonic elimination method of using coupling transformer in twelve pulse inverter is presented for high power application. This method is using coupling transformer and PWM(pulse width modulation) switching and voltage source inverter. The object of proposed harmonic elimination method is obtained inverter output of low THD(Total Harmonic Distortion). The simulation results confirm the proposed harmonic elimination method.

  • PDF

Design a Frequency-to-Digital Converter Using Delay Element (지연소자를 이용한 주파수-디지털 변환회로의 설계)

  • 최진호;김희정
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.1041-1044
    • /
    • 2003
  • In this paper, a new CMOS fully integrated frequency-to-digital converter is proposed. The operation of the proposed circuit is based on a pulse-shrinking delay element. In the proposed circuit, a resolution of the converted digital output can be easily improved by increasing the number of the pulse-shrinking element. Also the input frequency range can be easily changed through controlling bias voltage in the pulse-shrinking element. The simulation of the designed circuit carried out by HSPICE using the CMOS 0.35${\mu}{\textrm}{m}$ process technology.

  • PDF

The Optimum Control of the Sampled Data System by the Method of Pulse-Modulated Signal (샘플치 제어계의 팔스폭변조에 의한 최적제어특성)

  • Yang, Heung Suk;Kim, Kyong Ki
    • 전기의세계
    • /
    • v.20 no.1
    • /
    • pp.9-18
    • /
    • 1971
  • The characteristics of optimum control for the second order P.W.M. sampled-data system with linear plants are investigated, with the development of method for finding the cannonical represetations for the initial states, as well as the optimality of modulator output for the P.W.M. system, which contains the electro-mechanical components, by dividing the phase plane into several regions, in which the position of the system in the phase plane are converted into the pulse polarity and pulse width.

  • PDF

A Study of High Power Microwave Output by K-band Waveguide (K-band 도파관을 이용한 대전력 마이크로파 출력장치 연구)

  • Kim, Won-Sop
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.588-591
    • /
    • 2009
  • We had experimental studies of microwave output generator. We experimented with a corrugate-shped K-band slow wave guide in the backward wave oscillator. It generated output 표 interaction between electron beam's generation and magnetic field. We estimated oscillation frequency at 24GHz by changing propagation velocity and group velocity. We identified movement by second harmonic of Cherencov interaction and slow cyclotron mode. In our study we achieved oscillation stabilization, generation of long pulse, improvement of oscillation efficiency and output.

Design and embodiment of stable system by change of action waveform by pulsemodule special quality of pulse style$CO_2$ laser for obstetrics and gynecology (산부인과용 펄스형 $CO_2$레이저의 펄스모듈 특성과 동작파형 변화에 따른 안정된 시스템의 설계 및 구현)

  • Kim, Whi-Young
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.2
    • /
    • pp.97-102
    • /
    • 2007
  • [ $CO_2$ ] laser sees that is most suitable to get this effect through minimum formation damage and advantage that is root enemy of effect that happen in minimum cellular tissue depth of 0.1mm is stable living body organization or internal organs institution. Formation damage by ten can be related in formation's kind or energy density, length of evaporation time. If shorten evaporation time, surroundings cellular thermal damage 200 - because happen within 400um laser beam in rain focus sacred ground surroundings cellular tissue without vitiation me by evaporation Poe of very small floor as is clean steam can . Application is possible to vulva cuticle cousins by a paternal aunt quantity, uterine cancer, cuticle tumor by laser system that $CO_2$ laser gets into standard in obstetrics and gynecology application. Because effect that super pulse output is ten enemies of laser if uniformity one pulse durations are short almost is decreased, most of all pulse module special quality of Pulse style $CO_2$ laser for obstetrics and gynecology mode stabilization by weight very, in this research to get into short pulse duration and higher frequency density, do switching by high frequency in DC-DC Converter output DC's ripple high frequency to be changed, high frequency done current ripple amount of condenser for output filter greatly reduce can . Ripple of output approximately to Zero realization applying possible inductor realization through a special quality experiment do.

  • PDF

High-power Femtosecond Ti:sapphire Laser at 1 KHz with a Long-cavity Femtosecond Oscillator

  • Sung, Jae-Hee;Hong, Kyung-Han;Nam, Chang-Hee
    • Journal of the Optical Society of Korea
    • /
    • v.7 no.3
    • /
    • pp.135-138
    • /
    • 2003
  • A chirped-pulse amplification femtosecond Ti:sapphire laser operating at 1 KHz has been developed. The laser system consisted of a long-cavity femtosecond oscillator, a four-pass grating pulse stretcher, two multi-pass amplifiers and a double-pass grating pulse compressor. Thermal lensing at the amplifiers was reduced by cooling Ti:sapphire crystals using Peltier coolers. Gain narrowing and residual phase errors were compensated for by the use of an acousto-optic pulse shaper. The final laser output had an energy per pulse of 2.0 mJ and a pulse duration of 19.5 fs, reaching 0.1 TW at 1 KHz.

Novel Compact Current Type Pulse Power Generator

  • Min, B.D.;Kim, J.H.;Pavlov, E.;Yoo, D.W.;Rim, G.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.529-531
    • /
    • 2005
  • This paper proposes a compact pulse generator fur NOx removal application for diesel automotive. The rising time is important factor to increase NOx removal efficiency in pulsed corona discharge method. Manufacturing cost and compactness of the pulse power generator should be satisfied for automotive application. The proposed pulse power uses a low voltage thyristor, a pulse transformer with the function of saturated magnetic switch, and series connected general diodes as opening switch to satisfy that requirements. With 200 resistor load, the experiment results show that the output voltage is 21kV, the rising time is about 21ns, and the pulse width (FWHM) is about 42ns.

  • PDF

Pulse Compression of an Additive-Pulse Mode-Locked CW Nd:YLF Laser by Using an Optical Fiber and a Grating Pair (광섬유와 회절격자쌍을 이용한 Additive-Pulse Mode-Locking된 CW Nd:YLF 레이저의 광펄스 압축)

  • 안승준
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.1
    • /
    • pp.66-72
    • /
    • 1993
  • Additive-pulse mode-locking (APM) was performed in a $1.053{\mu}m$ cw Nd:YLF laser by coupling a nonlinear external external cavity to the main cavity. The APM pulsewidth was 4.5 ps and the average output power was 1.5 W. This APM pulse was compressed by an optical fiber and a grating pair to be as short as 210 fs with a peak power of 17 kW.

  • PDF