• Title/Summary/Keyword: Pulse injection

Search Result 245, Processing Time 0.023 seconds

A Clinical Study on the Effects of Intravenous Wild ginseng Herbal Acupuncture on the Human Body (정맥 주입용 산삼약침이 인체에 미치는 영향에 관한 임상적 연구)

  • Kwon, Ki-Rok
    • Journal of Pharmacopuncture
    • /
    • v.7 no.1 s.12
    • /
    • pp.15-26
    • /
    • 2004
  • Background : This study was conducted to evaluate the effects of wild ginseng herbal acupuncture developed for the intravenous use. Healthy male and female volunteers(n=57) went through Randomized Control Trials(RCT). Methods : For those who are under a medication due to common cold or other illnesses were excluded in the primary stage and the subjects with possible abnormalities in the pre-screening process were also excluded in the secondary stage. Then the examination groups were determined by random sampling. Experiment groups were divided into Normal saline injection group(control group), cultivated wild ginseng herbal acupuncture group(experiment group 1) and natural wild ginseng herbal acupuncture group(experiment group 2) Blood tension, body temperature, pulse, and other criteria were measured and analyzed. Results : 1. Intravenous injection of cultivated wild ginseng herbal acupuncture and natural wild ginseng herbal acupuncture didn't cause significant changes in the blood tension, pulse, body temperature, and etc. 2. No significant differences were witnessed in CBC, ESR, biochemistry of blood test and UA between the experiment groups. 3. No significant changes were noted in the thermography before and after the test in the experiment groups. 4. Some of the common physical changes occurring during and after the administration were fatigue, chest distension, and headache in all of the experiment groups. 5. Comparing general condition after one week from the termination of administration, the control group showed worst condition while as the natural wild ginseng herbal acupuncture group displayed best condition. Conclusion : From the above results, we can carefully deduce that the intravenous injection of the wild ginseng herbal acupuncture didn't show significant differences compared to injection of the normal saline. We can infer it is safe on the human body and further studies and reports must be followed.

A Novel Multi-Quantum Well Injection Mode Diode And Its Application for the Implementation of Pulse-Mode Neural Circuits (다중 양자우물 주사형 다이오드와 펄스-모드 신경회로망 구현을 위한 그 응용)

  • Song Chung Kun
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.62-71
    • /
    • 1994
  • A novel semiconductor device is proposed to be used as a processing element for the implementation of pulse-mode neural networks which consists of alternating n' GaAs quantum wells and undoped AlGaAs barriers sandwitched between n' GaAs cathode and P' GaAs anode and in simple circuit in conjunction with a parallel capacitive and resistive load the trigger circuit generates neuron-like pulse train output mimicking the function of axon hillock of biological neuron. It showed the sigmoidal relationship between the frequency of the pulse-train and the applied input DC voltage. In conjunction with MQWIMD the various neural circuits are proposed especially a neural chip monolithically integrated with photodetectors in order to perfrom the pattern recognition.

  • PDF

Analysis of Internal Energy Pulsation in MMC System According to Offset Voltage Injection with PWM Methods (PWM 방식을 이용한 옵셋 전압 주입에 따른 MMC 시스템 내부 에너지 맥동 분석)

  • Kim, Jae-Myeong;Jung, Jae-Jung
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1140-1149
    • /
    • 2019
  • In general, there are various pulse width modulation(PWM) methods simply using the offset voltage injection in voltage source converter(VSC). In accordance with the AC side voltage synthesis method with the offset voltage, DC side voltage utilization factor in VSC is changed. Also, this can apply equally to the MMC system. In other words, if the DC side capacity of the high voltage DC(HVDC) transmission system is determined, the maximum reactive power which can be supplied to the AC side can be changed according to the applied output voltage synthesis method with the offset voltage. In this paper, the leg energy pulsation in MMC system according to the AC side output voltage synthesis method with offset voltage which several representative PWM are applied to are mathematically analyzed and compared with each other. Finally, the above results are verified by simulation emulating the 400MVA full-scale MMC system to determine the consistency of the mathematical analysis.

HEMP Effect Analysis for Equipment Using Comparison of Norms between HEMP Filter Residual Current and Conducted Susceptibility Criteria (HEMP 필터 잔류 전류와 전도 내성 기준의 특성인자 비교를 통한 장비의 HEMP 영향성 분석)

  • Kwon, Joon-Hyuck;Song, Ki-Hwan;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.199-207
    • /
    • 2014
  • Although High-altitude electromagnetic pulse(HEMP) protection filter meets the requirements of pulsed current injection(PCI) acceptance test, the equipment under test which has low electromagnetic susceptibility level can be damaged during PCI verification test that is performed on operating condition of equipment. This paper proposed the HEMP effect analysis method using comparison of norms between residual current of HEMP filter and transient electromagnetic conducted susceptibility criteria of equipment, as an alternative method under the condition that performing PCI verification test is limited in HEMP hardened facilities. PCI acceptance test of HEMP filter, transient electromagnetic conducted susceptibility test, and PCI verification test are performed and test results are analyzed.

Analyses of Short Pulse Generation Using Heterodyne Techniques

  • Kim, Jung-Tae
    • Journal of information and communication convergence engineering
    • /
    • v.5 no.3
    • /
    • pp.281-284
    • /
    • 2007
  • We have analyzed the short pulse generation using heterodyne techniques. The numerical model for semiconductor lasers under the heterodyne technique is based on the Lang's equation and has been extended in order to take into account the simultaneous injection of the multiple sidebands of the current-modulated laser. The unselected sidebands will affect the optical and RF-spectral characteristics even when the semiconductor laser is locked to the target sidebands.

Analysis of Transient Diesel Spray with Visualization and Injection Rate Measurement (가시화와 분사율 측정을 통한 비정상 디젤분무의 분석)

  • Kang, Jin-Suk;Choi, Wook;Bae, Choong-Sik
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.5
    • /
    • pp.12-18
    • /
    • 2004
  • Transient natures of diesel sprays are often characterized with spray visualization, since it is a non-intrusive and straightforward technique to be applied. However, as injection pressure is increased higher than a thousand bar in a modern direct injection diesel engine, very fine temporal and spatial resolutions in the spray visualization are required while sprays become optically denser. Discussed in this paper are macroscopic and microscopic spray visualization techniques and an example of image processing process for efficient and consistent measurement of spray parameters. The injection rate measurement method based on hydraulic pulse principle was suggested as a way of estimating injection velocity for transient diesel sprays. The spray visualization and injection rate measurement techniques were applied to analyze transient diesel sprays from a common-rail injection system and found to be practically effective.

A Study on Malfunction Mode and Failure Rate Properties of Semiconductor by Impact of Pulse Repetition Rate (펄스 반복률에 의한 반도체 소자의 오동작 모드와 고장률에 관한 연구)

  • Park, Ki-Hoon;Bang, Jeong-Ju;Kim, Ruck-Woan;Huh, Chang-Su
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.6
    • /
    • pp.360-364
    • /
    • 2015
  • Electronic systems based on solid state devices have changed to be more complicated and miniaturized as the electronic systems developed. If the electronic systems are exposed to HPEM (high power electromagnetics), the systems will be destroyed by the coupling effects of electromagnetic waves. Because the HPEM has fast rise time and high voltage of the pulse, the semiconductors are vulnerable to external stress factor such as the coupled electromagnetic pulse. Therefore, we will discuss about malfunction behavior and DFR (destruction failure rate) of the semiconductor caused by amplitude and repetition rate of the pulse. For this experiment, the pulses were injected into the pins of general purpose IC due to the fact that pulse injection test enables the phenomenon after the HPEM is coupled to power cables. These pulses were produced by pulse generator and their characteristics are 2.1 [ns] of pulse width, 1.1 [ns] of pulse rise time and 30, 60, 120 [Hz] of pulse repetition rate. The injected pulses have changed frequency, period and duty ratio of output generated by Timer IC. Also, as the pulse repetition rate increases the breakdown threshold point of the timer IC was reduced.

The Effect of Auricular Acupuncture on the Pulse Rate (이침 요법이 맥박의 변화에 미치는 영향)

  • Jang, Jun-hyouk;Kim, Ji-young
    • Journal of Acupuncture Research
    • /
    • v.20 no.1
    • /
    • pp.97-103
    • /
    • 2003
  • Objective : Auricular acupuncture is a method of treatment that involves needling the ear in order to produce relief of symptoms. This concept was first developed by P.Nogier, french doctor and referred to as somatotopic representation. Many authors have commented the fact that the vagus nerve supplies the external auditory and the concha. The aim of this randomised, single blind study was to investigate whether auricular acupuncture of the ear produced changes in the pulse rate, an indicator of vagal tone. Methods: 10 healthy man volunteers were divided into normal and epinephrine stimulation group. Then each group was divided into vagus area acupuncture and control area acupuncture group again. Epinephrine stimulation group was injected by epinephrine 0.3cc twice, first. All of them were needled in either the vagus area or control area of the ear, and pulse rate changes were measured by patient monitor over 1 hour. Results : In the epinephrine stimulation group, there was significant differences in the pulse rate change between vagus area acupuncture and control area acupuncture group. After injection of epinephrine, the basal pulse rate was increased 1.3~1.4 times in the control group. However, in the vagus area acupuncture group the basal pulse rate was increased only 1.1~1.2 times.

  • PDF