• Title/Summary/Keyword: Pulse design

Search Result 1,442, Processing Time 0.031 seconds

The Effects of the Communication Accompanied with Music Therapy on the Anxiety of the Patients during the MRI Examination (MRI 검사 시 음악요법을 동반한 의사소통이 환자의 불안에 미치는 영향)

  • Yoon, Yong-Hak;Yoon, Hee-Jung;Lee, Sung-Kook;Kim, Kyung-Hee;Kwon, Gi-hong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.93-102
    • /
    • 2016
  • This study examined effects of the communication accompanied with music therapy on the anxiety of patients during a MRI examination. In the experiment group consisting of thirty patients and the control group consisting of thirty patients, the experiment was performed from February 1st 2014 to March 31st 2014 in hospital C located in Daegu Korea. The research design was a non-equivalent control group quasi-experimental study. The results showed that the anxiety score (VAS score) on communication with music therapy of the experimental group was significantly lower (p=.001), than that of the control group. Among the vital signs, the blood pressure was similar in both groups. On the other hand, the pulse rate of the experiment group was significantly lower (p=.001). Four categories of the physical discomfort (perspiration, facial change, change in physical posture, and change in vocal sound) did not show any statistically significant difference between the control and experiment group. Among the mental discomforts, dizziness did not have a significant difference between the experiment group and the control group, but the experimental group had significantly low fear (p=.001) and anxiety (p=.001). From the above results, communication accompanying music therapy proves is an effective alternative examination method that reduces the anxiety of patients.

Effects of Music Therapy on the Anxiety of Patients who Take the Magnetic Resonance Imaging(MRI) Test (음악요법이 자기공명영상(MRI) 검사시 환자의 불안에 미치는 영향)

  • Jeon, Byeong-Kyu;Yeo, Jin-Dong
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.6
    • /
    • pp.289-301
    • /
    • 2011
  • This study is a research based on the non-equivalent control group pretest-posttest design whose purpose is to examine the effects of music therapy on the anxiety of patients who take the magnetic resonance imaging(MRI) test and their feeling of discomfort during the test. "The first hypothesis that the experimental group who receive music therapy will be lower in score for anxiety during the MRI test than the control group who do not was supported because after the therapy, the experimental group was found significantly decreased in that score in comparison to the control group. "The second hypothesis that the experimental group who receive music therapy will be fewer in vital signs after the MRI test than the control group who do not" was rejected in terms of both systolic and diastolic blood pressure. But the same hypothesis was partially supported because the two groups showed a significant difference in pulse rate after the test. "The third hypothesis that the experimental group who receive music therapy will be less in the feeling of subjective discomfort during the MRI test than the control group who do not" was verified to find that the two groups were significantly different from each other in the feeling. Specifically, there was a significant difference between the two groups in only one sub-area of that feeling, that is, tension. These findings suggest that music therapy could be an alternative method which can effectively reduce the state anxiety of patients during the magnetic resonace imaging(MRI) test.

Development of Healthcare Bathing System for Improving the Multisensory Functions (복합감각 기능증진 개념의 헬스케어 목욕시스템 개발)

  • Kim, Hyung-Ji;Yu, Mi;Jin, Hea-Ryen;Kwon, Tae-Kyu
    • Science of Emotion and Sensibility
    • /
    • v.13 no.2
    • /
    • pp.309-316
    • /
    • 2010
  • This paper proposes healthcare bathing system for improving the multisensory function and not washing. We designed various types of bathtub for developing bathing system. This system consists of whirlpool bathtub for multisensory stimulation, a cover of bathtub with visual-auditory stimulation function, a small size PC for main control, touch panel, digital multimedia broadcasting (DMB), color-changeable LED mood lighting system for improving visual sensibility and speaker. We investigate the effects on autonomic nervous system during bathing with healthcare bathing system for improving the multisensory functions. To analysis physiological parameter, body temperature, blood pressure, intraocular pressure and heart rate variability (HRV) were measured before, during and after bath using healthcare bathing system. Experiments were performed on partial immersion bath and the water temperature was kept $39{\pm}0.5^{\circ}C$. The body temperature and the heart rate variability of the subject were measured every 5 minutes before, during, and after the bath. In analysis of HRV, the parasympathetic nerve increased from starting bath and decreased after 15 minutes. So the subjects felt comfortable at 15 minutes after starting bath. Blood pressure decreased to 16mmHg maximumly however pulse increased. Bath using healthcare bathing system for improving the multisensory functions affects positively the circulation of the blood. From this results, it leaves something to be desired in evaluation of serviceability and physiological analysis using the healthcare bathing system, however, we expect to analyze more clearly the relationship between the serviceability of product, physiological change and sensibility by various physiological parameters.

  • PDF

Design of a PWM DC-DC Boost Converter IC for Mobile Phone Flash (휴대전화 플래시를 위한 PWM 전류모드 DC-DC converter 설계)

  • Jung, Jin-Woo;Heo, Yun-Seok;Park, Yong-Su;Kim, Nam-Tae;Song, Han-Jung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2747-2753
    • /
    • 2011
  • In this paper, a PWM current-mode DC-DC boost converter for mobile phone flash application has been proposed. The converter which is operated with 5 Mhz high switching frequency is capable of reducing mounting area of passive devices such as inductor and capacitor, consequently is suitable for compact mobile phones. This boost converter consists of a power stage and a control block. Circuit elements of the power stage are inductor, output capacitor, MOS transistors and feedback resistors. Meanwhile, the control block consists of pulse width modulator, error amplifier, oscillator etc. Proposed boost converter has been designed and verified in a $0.5\;{\mu}m$ 1-poly 2-metal CMOS process technology. Simulation results show that the output voltage is 4.26 V in 3.7 V input voltage, output current 100 mA which is larger than 25 ~ 50 mA in conventional 500 Khz driven converter when the duty ratio is 0.15.

A Design of Key Generation and Communication for Device Access Control based on Smart Health Care (스마트 헬스케어 기반의 디바이스 접근제어를 위한 키 생성 및 통신기법 설계)

  • Min, So-Yeon;Lee, Kwang-Hyong;Jin, Byung-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.746-754
    • /
    • 2016
  • Smart healthcare systems, a convergent industry based on information and communications technologies (ICT), has emerged from personal health management to remote medical treatment as a distinguished industry. The smart healthcare environment provides technology to deliver vital information, such as pulse rate, body temperature, health status, and so on, from wearable devices to the hospital network where the physician is located. However, since it deals with the patient's personal medical information, there is a security issue for personal information management, and the system may be vulnerable to cyber-attacks in wireless networks. Therefore, this study focuses on a key-development and device-management system to generate keys in the smart environment to safely manage devices. The protocol is designed to provide safe communications with the generated key and to manage the devices, as well as the generated key. The security level is analyzed against attack methods that may occur in a healthcare environment, and it was compared with existing key methods and coding capabilities. In the performance evaluation, we analyze the security against attacks occurring in a smart healthcare environment, and the security and efficiency of the existing key encryption method, and we confirmed an improvement of about 15%, compared to the existing cipher systems.

A Design of DLL-based Low-Power CDR for 2nd-Generation AiPi+ Application (2세대 AiPi+ 용 DLL 기반 저전력 클록-데이터 복원 회로의 설계)

  • Park, Joon-Sung;Park, Hyung-Gu;Kim, Seong-Geun;Pu, Young-Gun;Lee, Kang-Yoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.4
    • /
    • pp.39-50
    • /
    • 2011
  • In this paper, we presents a CDR circuit for $2^{nd}$-generation AiPi+, one of the Intra-panel Interface. The speed of the proposed clock and data recovery is increased to 1.25 Gbps compared with that of AiPi+. The DLL-based CDR architecture is used to generate the multi-phase clocks. We propose the simple scheme for frequency detector (FD) to mitigate the harmonic-locking and reduce the complexity. In addition, the duty cycle corrector that limits the maximum pulse width is used to avoid the problem of missing clock edges due to the mismatch between rising and falling time of VCDL's delay cells. The proposed CDR is implemented in 0.18 um technology with the supply voltage of 1.8 V. The active die area is $660\;{\mu}m\;{\times}\;250\;{\mu}m$, and supply voltage is 1.8 V. Peak-to-Peak jitter is less than 15 ps and the power consumption of the CDR except input buffer, equalizer, and de-serializer is 5.94 mW.

Effects of the 'Intervention - Mother's Song' on Physical Response and Behavioral State of Low-Birth Weight Infants in a Neonatal Intensive Care Unit (어머니의 노래 들려주기 중재가 저출생체중아의 생리적 반응과 행동상태에 미치는 효과)

  • Park, Ji-Sun;Hong, Kyung-Ja;Bang, Kyung-Sook
    • Child Health Nursing Research
    • /
    • v.19 no.3
    • /
    • pp.198-206
    • /
    • 2013
  • Purpose: This study was done to identify the effectiveness of the 'intervention - mother's recorded song' on low-birth weight infants in an neonatal intensive care unit (NICU). Methods: This study was conducted with a nonequivalent control group pre-posttest quasi-experimental design and the participant group was low-birth weight infants who were admitted to the NICU. Forty-eight infants, 24 in each from two groups, the experimental and control group, participated in the study. Results: For physical response according to vital signs, there were no significant statistical differences in heart rate, respiration rate and pulse oximetry saturation between the experimental group and the control group. For behavioral state, there was a significant statistical difference between the experimental and control group. Conclusion: The study results indicate that the intervention using mother's song had some significance as a nursing intervention with positive impacts. Such an intervention can help pediatric nurses improve infants' stabilization of their vital signs and behavioral states. By showing the effectiveness of such an intervention, the results of this study provide further evidence-based information in developing the practice of pediatric nursing.

A Design of Prescaler with High-Speed and Low-Power D-Flip Flops (고속 저전력 D-플립플롭을 이용한 프리스케일러 설계)

  • Park Kyung-Soon;Seo Hae-Jun;Yoon Sang-Il;Cho Tae-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.42 no.8 s.338
    • /
    • pp.43-52
    • /
    • 2005
  • An prescaler which uses PLL(Phase Locked Loop) must satisfy high speed operation and low power consumption. Thus the performance or TSPC(True Single Phase Clocked) D-flip flops which is applied at Prescaler is very important. Power consumption of conventional TSPC D-flip flops was increased with glitches from output and unnecessary discharge at internal node in precharge phase. We proposed a new D-flip flop which reduced two clock transistors for precharge and discharge Phase. With inserting a new PMOS transistor to the input stage, we could prevent from unnecessary discharge in precharge phase. Moreover, to remove the glitch problems at output, we inserted an PMOS transistor in output stage. The proposed flip flop showed stable operations as well as low power consumption. The maximum frequency of prescaler by applying the proposed D-flip flop was 2.92GHz and achieved power consumption of 10.61mw at 3.3V. In comparison with prescaler applying the conventional TSPC D-flip $flop^[6]$, we obtained the performance improvement of $45.4\%$ in the view of PDP(Power-Belay-Product).

A Study and Design of Beam Scanning Array Antenna using IR-UWB (IR-UWB를 이용한 빔 스캐닝 배열 안테나 설계 및 연구)

  • Kim, Keun-Yong;Kang, Eun-Kyun;Kim, Jin-Woo;Ra, Keuk-Whan
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.3
    • /
    • pp.194-201
    • /
    • 2014
  • This paper is able to be solved by improving degradation in multi-path environment by adjust beam pattern angle through modifying pulse phase of each antennas by using TRM (Transmitter Receiver Module). Beam Scanning Array Antenna, which is transmitter/receiver that improves degradation in multi-path environment without any signal distortion, is designed and manufactured. Beam Scanning Array Antenna should be able to send/receive signal at the antenna's longitudinal part without distortion and should not influences other systems. Also, it should include target detecting ability by beam steering.Dispersion characteristic of Beam Scanning Antenna, which is designed, is analysed by using fidelity, and steering and radar resolution performance is verified by using $1cm{\times}1cm$ sized target. To manufacture Beam Scanning Array Antenna, control board and GUI, which is able to control Vivaldi Antenna for IR-UWB, Tri-Band Wilkinson power divider, and TRM (Transmitter Receiver Module), is designed. Throughout this research, developed Beam Scanning UWB Array Antenna system is adoptable for radar application field. and time domain analysis techniques by using network analyser made the antenna characteristics analysis for setting up antenna more accurate. In addition, it makes beam width checking without difficulties.

Effects of Post-Tensioning Tendons and Vehicle Speeds on Dynamic Response of Concrete-Filled Steel Tubular Tied Arch Girder (긴장재 및 차량속도 변화에 따른 콘크리트 충전 타이드 아치형 거더의 동적거동)

  • Roh, Hwasung;Hong, Sanghyun;Park, Kyunghoon;Lee, Jong Seh
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3A
    • /
    • pp.163-172
    • /
    • 2011
  • The CFTA girder developed is a concrete filled steel tubular system with arched shape and external post-tensioning (PT) tendons which control the initial camber and the bending stress of the girder. In the present study the effects of the PT tendons on the dynamic behavior of the girder subjected to a moving vehicle load are numerically investigated. Various levels for the tendon quantity and the tendon forces are considered, using the existing FE model of the girder. The vehicle considered is a DB-24 truck and is modeled with two tracks-three axles. Equivalent-load pulse time histories are applied to each node to simulate the moving vehicle, depending on the time of arrival and the discretization. The vehicle speeds are varied from 40 km/hr to 100 km/hr with increment of 20 km/hr. The analysis results show that the tendon forces do not produce any influences on the dynamic responses of the girder. However the dymamic deflection of the girder increases when a smaller amount of tendons is used. The Dynamic Amplification Factors (DAF) are evaluated based on the static and dynamic responses. Much lower values of the DAF are obtained, even no tendons applied, than those provided by the design criteria of the AASHTO LRFD and the Korea Highway Standard Specification.