• Title/Summary/Keyword: Protocol analyzer

Search Result 70, Processing Time 0.023 seconds

Implementation of ISDN User/Network Protocol Analyzer on PC-based System (PC 환경에서 ISDN 사용자/망 프로토콜 분석기의 개발)

  • 정중수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1068-1073
    • /
    • 1999
  • On the emergence of ISDN which has been introduced in the year 1980, various services are supported. This paper presents implementation of ISDN user/network protocol analyzer based on PC-extension card. Firmware and software are loaded on the PC-extension card using PC 05. The performance analysis on D-channel signalling on this system is surveyed. The monitoring results satisfiy with ISDN BRI or PRI interfaces.

  • PDF

Design and Implementation of Protocol Analyzer for USN (USN 위한 프로토콜 분석기 설계 및 구현)

  • Kim, Se-Han;Kim, Nae-Soo;Kim, Byung-Chul;Lee, Jae-Yong
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.8 no.3
    • /
    • pp.138-143
    • /
    • 2009
  • 다양한 서비스에서 활용되는 USN환경에서 각 응용의 기술적 특성에 따른 다양한 프로토콜기술의 개발이 이루어지고 있다. 본 논문에서는 무선 센서 네트워크 프로토콜 개발에 필수인 프로토콜 분석기에 대한 것으로 8개(최대 16개) 트랜시버를 갖는 하드웨어를 통해 무선 상의 여러 채널을 통해 송수신 되는 다양한 프로토콜을 쉽게 분석하는 장치의 구현에 대해 설명한다. 종래의 기술은 Zigbee프로토콜과 같은 특정한 프로토콜 및 하나의 채널만을 대상으로 분석하여 화면에 출력하는 기술인 것에 비하여, 본 기술은 여러 개의 채널을 동시에 분석이 가능하며, 동시에 여러 개의 채널을 통해 패킷을 인코딩하여 출력이 가능하다. 또한 하드웨어 및 소프트웨어의 코드를 바꾸지 않고 XML을 활용하여 사용자 정의에 따른 프로토콜 분석 및 처리, GUI처리 등을 가능하게 한다.

  • PDF

Analysis of Network Log based on Hadoop (하둡 기반 네트워크 로그 시스템)

  • Kim, Jeong-Joon;Park, Jeong-Min;Chung, Sung-Taek
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.125-130
    • /
    • 2017
  • Since field control equipment such as PLC has no function to log key event information in the log, it is difficult to analyze the accident. Therefore, it is necessary to secure information that can analyze when a cyber accident occurs by logging the main event information of the field control equipment such as PLC and IED. The protocol analyzer is required to analyze the field control device (the embedded device) communication protocol for event logging. However, the conventional analyzer, such as Wireshark is difficult to process the data identification and extraction of the large variety of protocols for event logging is difficult analysis of the payload data based and classification. In this paper, we developed a system for Big Data based on field control device communication protocol payload data extraction for event logging of large studies.

A Study on communication Protocol of KTX TECA(Terminal Cabin) (KTX 운전자지원 단말기장치 통신프로토콜에 관한 연구)

  • Jung, Sung-Youn;Park, Shin-Ho;Kim, Hyeoung-In;Kim, Chi-Tae;Kang, Ki-Sok;Lee, Byung-Won;Lee, Dong-Soo;Jung, Do-Won
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1714-1721
    • /
    • 2007
  • TECA (Terminal Cabin), the terminal device which offers the information to the driver about the condition of High Speed Train(KTX), analyzes the system of train and plays a role of corrective maintenance guideline to a driver when a breakdown occurs. It also supports the driver to decide the situation of the train by offering a necessary information, in communicating with MPU(Main Processor Unit). For Localization of TECA, it is necessary to analyze communication protocol between TECA and MPU. As a part of analysis, communication protocol between OBCS(on-board computer system) and add-on devices has analyzed for the first step. Also with protocol analyzer appropriate method was offered for TECA and MPU protocol analysis. Finally, by appling proposed method to the drivers consol suitability was verified.

  • PDF

Porting Point-to-Point Protocol(PPP) Software to an Embedded System (임베디드 시스템으로의 Point-to-Point Protocol(PPP) 소프트웨어 이식)

  • Choe, Seong-Jong
    • The Transactions of the Korea Information Processing Society
    • /
    • v.7 no.7
    • /
    • pp.2135-2148
    • /
    • 2000
  • Developing network software in embedded systems, such as digital set-top boxes, requires coding under limited computing resources. This paper presents the porting of Point-to-point Protocol (PPP) software, PPPD, to an embedded system. The PPP is the most popular link layer protocol for the information appliance, to an embedded system. In order to achieve this, problems to be solved for the porting were identified and methods to solve the problems were described. First, PPP source codes were divided into modules. Next, functions of each module were analyzed and interfaces between the modules were delineated. With the analysis results, porting to the embedded system was described. The normal operation of the ported software was verified with the help of a network packet analyzer. Finally, experiences during the porting were presented. The method developed in th paper can be applied to the porting of software to an embedded system as well as the porting of network software.

  • PDF

Comparative Studies on the Concordance Rate of Pulse Condition Interpretation between Interpreters and Pulse Analyser (맥진기 결과에 대한 판독자간의 판독 일치율 비교 연구)

  • Kang, Sei-Young;Jang, In-Soo;Kim, Lak-Hyung
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.91-99
    • /
    • 2011
  • Objectives : The purpose of our investigation is to determine degrees of concordance rate among interpreters. Furthermore, we have examined how much concordance rate to come out when beginners have been compared with the pulse analyzer. Methods : Thirty-nine volunteers were enrolled for this study. These subjects took a 5-minute rest in a sitting position as instructed by the protocol. As they were not allowed to move or speak, radial artery pulse conditions were measured on the lower arm of each subject by means of the pulse analyzer under investigation. Two Korean medical doctors, who did not know the status of default pulse conditions, were also instructed to intuitively choose the most corresponding one in comparison with 13 default pulse conditions. Subsequently, we investigated results between interpreters as well as results between interpreter and pulse analyzer. Results : The total concordance rate, with similar concordance rates being included, between interpreters, between interpreter A and pulse analyzer, and between interpreter B and pulse analyzer was 56.4%, 79.5%, and 71.8% respectively. In faint fine weak pulse(微細弱脈) case, interpreter A and B selected 6 and 7 cases respectively, matched the concordance rate 5, and corresponded separately with the pulse analyzer interpreting 8 cases. Conclusions : In case of skipping pulse 2(促2脈), short pulse(短脈), faint fine weak pulse(微細弱脈), the concordance between interpreters also matches with results drawn from the pulse analyzer. The concordance rate goes higher in proportion with such smaller pulse conditions as faint fine weak pulse(微細弱脈) and short pulse(短脈).

Design and Implementation of A VXIbus Device for FFT Analysis (FFT분석을 위한 VWIbus 디바이스의 설계 및 구현)

  • 강민호;노승환;전동근;문대철;김덕진
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.11
    • /
    • pp.1754-1766
    • /
    • 1993
  • The application of VXIbus system, an Industry standard, is rapidly spreading with its ability to offer the easiness of integration from GPIB and the fast data transmission from VMEbus system. Compared with VXIbus Register Based Device, VXIbus Message Based Device has a drawback In the aspect of speed. But it is possible to utilize high level ASCII commands to control a Message Based Device, therefore system integration is much easier with Message Based Device than with Register Based Device. And, the FFT analyzer is an instrument for signal analysis which can be inexpensively implemented to be fast and have high resolution. Its wide ability of analysis presents numerous application. So, it is necessary to apply VXIbus system to FFT analyzer. In this paper, the implementation of FFT analyzer is performed using a DSP module and by implementing all A/D conversion circuit and a control module which performs VXIbus interface. The device can be controlled by Slot0 Commender which supports VXIbus Shared Memory Protocol through VXIbus.

  • PDF

Development of Conformance Test Tools for Terrestrial DMB Broadcast Web Site Services (지상파 DMB 방송웹사이트 서비스 송수신 정합 시험 도구 개발)

  • Kim, Yong-Han;Moon, Su-Han;Chae, Young-Seok
    • Journal of Broadcast Engineering
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2007
  • In this paper, we presents conformance test tools for the broadcast web site (BWS) service which is one of the data services for terrestrial digital multimedia broadcasting (T-DMB). First, the methodology for the conformance test is established for both transmitters and receivers of T-DMB BWS services. The test tools consist of three parts: BWS bitstream analyzer, BWS reference decoder (software) module, and BWS test bitstreams. For testing transmitted BWS bitstreams, we developed the bitstream analyzer. For testing BWS receivers, we developed the reference Ifecoder module and created the test bitstreams. Actually the bitstream analyzer developed in this paper was used for the verification of the test bitstreams. The same test bitstreams are fed to a BWS decoder module under test and the reference decoder module and the results from the two are compared for verification. The test tools can be used for the test of all the protocol and textual/image specifications related to BWS including MOT protocol, HTML, PNG, MNG, JPEG, and Ecma Script.

Evaluation of AFDX Certification Support System by both AFDX Tap and AFDX Analyzer (AFDX Tap과 AFDX 프로토콜 분석기를 이용한 AFDX 네트워크 인증 기술)

  • Park, Pusik;Son, Myeonghwan;Lee, Jeongdo;Yoon, Jongho
    • Journal of Aerospace System Engineering
    • /
    • v.16 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • Avionics Full-DupleX Ethernet (AFDX) is a next-generation avionics network interface technology that is widely applied in the latest aircraft to replace ARINC429 and MIL-STD-1553B. However, the criteria for authenticating an avionics network consisting of AFDX are very scarce. Using AFDX Protocol Analyzer developed by the Korea Electronics Technology Research Institute and AFDX Tap developed by the Korea Aerospace University, we proposed a technology of certification practicality that can verify the normal functioning of avionics equipment with AFDX network interface. Our proposed technology provided the ability to collect precision packets, to verify AFDX specification compliance, and perform automatic tests to reduce the time and cost of authentication of AFDX avionics devices.

Design and Implementation of IR-UWB Packet Analyzer Based on IEEE 802.14.5a (IEEE 802.15.4a IR-UWB 패킷 분석기 설계 및 구현)

  • Lim, Sol;Lee, Kye Joo;Kim, So Yeon;Hwang, Intae;Kim, Dae Jin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.12
    • /
    • pp.2857-2863
    • /
    • 2014
  • IR-UWB has been developed as a standard of indoor ranging technology, because it has robust and good transmission characteristics in indoor environments and it can be operated with low power. In this paper, a IR-UWB packet analyzer is designed and implemented based on IEEE 802.15.4a, which is useful in developing IR-UWB real time location system with resolution of a few ten centimeters. A sniffer device of the packet analyzer monitors IR-UWB wireless networks, captures MAC packet frames, and transmits packet frames to the packet analyzing computer. The packet analyzing program in a computer analyzes received MAC packet frames and displays parsed packet information for developing engineers. Developed packet analyzer is used to analyze IEEE 802.15.4a MAC protocol, and also it can be used in other IEEE 802 series MAC protocol by modifying some functions.