• 제목/요약/키워드: Protection Capability Evaluation

검색결과 40건 처리시간 0.026초

A Probabilistic Approach to the Protection Capability Evaluation of Distance Relay in Transmission Systems

  • Zhang, Wen-Hao;Lee, Seung-Jae;Choi, Myeon-Song
    • Journal of Electrical Engineering and Technology
    • /
    • 제5권3호
    • /
    • pp.407-414
    • /
    • 2010
  • This paper proposes a probability measure for the evaluation of relay performance from two aspects, namely, correct trip and no-unwanted trip. They are developed based on the relationship between relay settings and relay measurements, which follow a Gaussian probability model. The proposed method based on strict mathematical derivation is applied to protection capability evaluation of distance relays under various settings. Considering the specific attributes of each protection zone, the optimal settings are also determined accordingly. The protection capability could demonstrate clearly the relay performance under various settings and the optimal settings could provide good references for engineering applications.

Protectability: An Index to Indicate Protection Level of Primary Distribution Systems

  • Lee, Seung-Jae;Park, Myeon-Song;Kang, Sang-Hee;Kim, Sang-Tae
    • KIEE International Transactions on Power Engineering
    • /
    • 제3A권1호
    • /
    • pp.7-16
    • /
    • 2003
  • A new method to evaluate the protection capability of distribution systems is reported in this paper. This work describes the fuzzy evaluation attributes and aggregation method of evaluation results based on a hierarchical model and the modified combination rule. An evaluation grade index called "protectability" is proposed and is expected to be a very uscful tool in defining an optimal protection and realizing the adaptive protection.rotection.

Conventional CMOS 공정을 위한 GGNMOS Type의 ESD 보호소자의 TLP 특성 평가 (TLP Properties Evaluation of ESD Protection Device of GGNMOS Type for Conventional CMOS Process)

  • 이태일;김홍배
    • 한국전기전자재료학회논문지
    • /
    • 제21권10호
    • /
    • pp.875-880
    • /
    • 2008
  • In this paper, we deal with the TLP evaluation results for GGNMOS in ESD protection device of conventional CMOS process. An evaluation parameter for GGNMOS is that repeatability evaluation for reference device($W/L=50\;{\mu}m1.0\;{\mu}m$) and following factors for design as gate width, number of finger, present or not for N+ gurad -ring, space of N-field region to contact and present or not for NLDD layer. The result of repeatability was showed uniformity of lower than 1 %. The result for design factor evaluation was ; 1) gate width leading to increase It2, 2) An increase o( finger number was raised current capability(It2), and 3) present of N+ gurad-ring was more effective than not them for current sink. Finally we suggest the optimized design conditions for GGNMOS in evaluated factor as ESD protection device of conventional CMOS process.

TLP 평가기법을 이용한 Diode type의 ESD 보호소자 특성 평가 (Properties evaluation for ESD Protection device of Diode type using TLP evaluation method)

  • 이태일;김홍배
    • 반도체디스플레이기술학회지
    • /
    • 제6권4호
    • /
    • pp.53-57
    • /
    • 2007
  • In paper, We evaluated for various diode type ESD protection device using TLP measurement method. An Evaluation diode is divided to Enclosed type and Stripe type as pattern style in extensive. These diodes is split up followed factor that Anode-to-Cathod space, N+ region width, Multi type and Contact to Active space. After a TLP measurement, we can be got the Vt2, It2 by I-V characteristic values. In the results, diode of enclosed type is present relatively higher Current capability(It2) than stripe type in a same voltage conditions. And the Second-breakdown voltage(Vt2) were that Stripe type's diode higher than Enclosed type's diode as have $14{\sim}15V$. Finally we suggest the best diode design condition as ESD protection device using entire consequence.

  • PDF

태양광발전용 인버터 보호기능시험 성능평가 (Performance Evaluation with Protective Function test of Inverter for Solar Power Generation)

  • 윤용호
    • 전기학회논문지
    • /
    • 제67권11호
    • /
    • pp.1570-1575
    • /
    • 2018
  • The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. The increased penetration of PV is impacting on grid operation and in particular the voltage within the local grid can be significantly influenced by the various PV systems. This paper describes domestic technical standard of Photovoltaic(PV) PCS(Power Conditioning Systems)- Characteristics of the utility interface. Especially protective function test items of 1) Output overvoltage protection test, 2) Output undervoltage protection test, 3) Frequency rise protection test, 4) Frequency fall protection test, 5) System voltage's momentary interruptions, 6) System voltage distortion capability test. Therefore in this paper protective function test item of facilities evaluation detailed standards for new renewable energy, small, medium and large photovoltaic inverter standard is studied and analyzed and finally full tested by PV inverter performance function.

Salmonella enterica serovars Enteritidis의 온도감수성 변이주 및 폴리인산키나아제 변이주의 제작과 방어효과 (Development and evaluation of protective capacity of Salmonella Enteritidis polyphosphate kinase-deleted and temperature-sensitive mutant)

  • 김기주;박소연;조영재;곽정연;강정무;김은희;최환원;원호근;노윤희;한태욱
    • 대한수의학회지
    • /
    • 제53권4호
    • /
    • pp.211-216
    • /
    • 2013
  • This study was focusing on evaluating the protection of polyphosphate kinase (ppk) deleted and/or temperature-sensitive (ts) Salmonella Enteritidis (SE) as an attenuated vaccine in chickens. We constructed SEppk, SEts and SEppk::ts mutants and screened those mutants by growth capability in vitro, protection study in mice model and antibody response in chickens. Among the mutants, SEppk::ts-3 was selected because it showed higher growth capability, good protection against highly virulent SE in mice model, and good antibody response in chickens. SEppk::ts-3 also showed good protection against highly virulent SE isolate because it decreased colonization of virulent SE challenge strain in spleen, liver and cecum compared with the non-vaccinated control. The SEppk::ts-3 mutant showed cross-protection against S. Gallinarum (SG) challenge although the its cross-protection rate was a little lower than that of SG9R, a commercial vaccine against SG infection. To use for live attenuated vaccine in chickens, it should further be characterized.

국방조직의 정보보호 평가 방법론 개발 (Development of the Information Security Methodology for Defense Organization)

  • 조성림;최인수;박지훈;신우창
    • 한국IT서비스학회지
    • /
    • 제12권4호
    • /
    • pp.77-90
    • /
    • 2013
  • As Cyber threats are rising, the scope of information Security (IS) is extending from technical protection of a single information system to organizational comprehensive IS capability. The ministry of National Defense (MND) has established the IS evaluation for defense organization in 'the Directive for Defense Informatization Affairs.' However, no information about an evaluation method, process and organization is provided. We surveyed information security management system (ISMS) and related best practices in public sector and other countries, and analysed the military information security affairs. Thus, this paper recommends the IS evaluation method and process. The trial IS evaluation is in progress this year and the MND will expand this IS evaluation to the entire organization.

FACTS적용계통에서의 송전용량 평가 알고리즘 (An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device)

  • 윤용범;윤종수;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF

한국형 전술차량 방탄유리 환경 및 방호력 시험 적용 기법 연구 (A Study of Environment & Bullet-Proof Capability Test Method for KLTV's Transparent Armour)

  • 박진원;박영찬;김선진
    • 한국군사과학기술학회지
    • /
    • 제21권1호
    • /
    • pp.69-73
    • /
    • 2018
  • Korean-peacekeeper's transparent armors in Iraq showed delamination, cracking and clouding a decade ago. And there were also similar deterioration recurrences in KLTV during the operational test a few years ago. Also, the differences between operational capability & lab Bullet-proof test condition, and insufficiency of military protection spec resulted in incomplete bullet-proof results. Moreover, although so many ground weapon systems have been developed, there were not secure test & evaluation codes to verify transparent armoured glasses equal to advanced-overseas products. So in this study, first, environmental test codes were established that all tests should be carried out as the application of only one specimen with newly adopted thermal shock test instead of completing each test with different one. Second, protection standards were integrated through the analysis of global developed country's specifications and reinforced as adding to the real mock-up condition if vehicle's glasses are smaller than standard specimen. Hereby, by applying to test-codes which including actual operational & vehicular conditions, the gap between development test and operational environment was minimized.