• 제목/요약/키워드: Process tomography

검색결과 373건 처리시간 0.026초

Initial Study of a Wire Mesh Tomography Sensor for Liquid/Gas Component Investigation

  • Rahiman, M.H.F.;Siow, L.T.;Rahim, R.A.;Zakaria, Z.;Ang, Vernoon
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권5호
    • /
    • pp.2205-2210
    • /
    • 2015
  • Experimental studies have been carried out to study the principle operation of the conductive type wire-mesh tomography sensor and analyse the wire-mesh tomography sensor for the liquid/gas two-phase flow interface and void fraction distribution in a process column. The measurement of the two-phase flows in the process column is based on the cross-sectional local instantaneous conductivity. The sensor consists of two planes of parallel electrode wires with 16 electrodes each and was placed orthogonally with each plane. The sensor electrode wires were made of tinned copper wire with an outer diameter of 0.91 mm which stretched over the sensor fixture. Therefore, this result in the mesh grid size with 5.53×5.53mm2. The wire-mesh sensor was tested in a horizontal liquid/gas two-phase flows process column with nominal diameter of 95.6 mm and the sampling frequency of 5882.3529 Hz. The tomogram results show that the wire-mesh tomography provides significant results to represent the void fraction distribution in the process column and estimation error was found in the liquid/gas interface level

Nonlinearity-Compensation Extended Kalman Filter for Handling Unexpected Measurement Uncertainty in Process Tomography

  • Kim, Jeong-Hoon;Ijaz, Umer Zeeshan;Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1897-1902
    • /
    • 2005
  • The objective of this paper is to estimate the concentration distribution in flow field inside the pipeline based on electrical impedance tomography. Special emphasis is given to the development of dynamic imaging technique for two-phase field undergoing a rapid transient change. Nonlinearity-compensation extended Kalman filter is employed to cope with unexpected measurement uncertainty. The nonlinearity-compensation extended Kalman filter compensates for the influence of measurement uncertainty and solves the instability of extended Kalman filter. Extensive computer simulations are carried out to show that nonlinearity-compensation extended Kalman filter has enhanced estimation performance especially in the unexpected measurement environment.

  • PDF

전산화 단층촬영 투시하 성상 신경절의 경피적 고주파 열 응고술 -증례 보고- (Computerized Tomography-guided Percutaneous Radiofrequency Thermocoagulation of Stellate Ganglion -A case report-)

  • 정준석;최락민
    • The Korean Journal of Pain
    • /
    • 제12권1호
    • /
    • pp.128-131
    • /
    • 1999
  • Stellate ganglion block is a well established method for the management of certain pain syndromes (e.g., chronic regional pain syndrome, facial pain) in the cervicothoracic region and upper extremity. The stellate ganglion resides between the C7 transverse process and the head of the first rib. Anesthetic injections for the stellate ganglion block are typically made at the level of the transverse process of either the C6 or C7 vertebrae to avoid the pleura, vessels, and nerve roots. Method of positioning the needle tip directly at the ganglion has been described, but are problematic because of the risk of injury to or injection into adjacent structures. It is necessary to know the exact anatomic position of the stellate ganglion when permanent blockade is required by means of radiofrequency thermocoagulation. Whereas fluroscopy shows only bony feature, computerized tomography also images nerves, vessels, and lung, allowing accruate needle placement. We report a case of the percutaneous radiofrequency thermocoagulation of the stellate ganglion after computerized tomography-guided localization.

  • PDF

불균질 이방성 매질에서의 탄성파 주시 토모그래피 (Seismic Traveltime Tomography in Inhomogeneous Anisotropic Media)

  • 정창호;서정희
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2007년도 공동학술대회 논문집
    • /
    • pp.209-214
    • /
    • 2007
  • In Korean geology that crystalline rock is dominant, the properties of subsurface including the anisotropy are distributed complexly and changed abruptly. Because of such geological environments, cross-hole seismic traveltime tomography is widely used to obtain the high resolution image of the subsurface for the engineering purposes in the geotechnical sites. However, because the cross-hole tomography has a wide propagation angle coverage relatively, its data tend to include the seismic velocity anisotropy comparing with the surface seismic methods. It can cause the misinterpretation that the cross-hole seismic data including the anisotropic effects are analyzed and treated with the general processing techniques assuming the isotropy. Therefore, we need to consider the seismic anisotropy in cross-hole seismic traveltime tomography. The seismic anisotropic tomography algorithm, which is developed for evaluation of the velocity anisotropy, includes several inversion schemes in order to make the inversion process stable and robust. First of all, the set of the inversion parameters is limited to one slowness, two ratios of slowness and one direction of the anisotropy symmetric axis. The ranges of the inversion parameters are localized by the pseudo-beta transform to obtain the reasonable inversion results and the inversion constraints are controlled efficiently by ACB(Active Constraint Balancing) method. Especially, the inversion using the Fresnel volume is applied to the anisotropic tomography and it can make the anisotropic tomography more stable than ray tomography as it widens the propagation angle coverage.

  • PDF

Foramen transversarium enlargement caused by vertebral artery tortuosity: Diagnosis with cone-beam computed tomography and magnetic resonance angiography

  • Omami, Galal
    • Imaging Science in Dentistry
    • /
    • 제51권3호
    • /
    • pp.329-332
    • /
    • 2021
  • A markedly enlarged foramen transversarium was discovered incidentally on a cone-beam computed tomography scan of a 72-year-old male patient who was referred for dental implant placement. Further evaluation with magnetic resonance angiography revealed that the foramen enlargement was caused by a tortuosity in the course of the vertebral artery. This case report highlights the importance of recognizing significant incidental findings on diagnostic images and the potential need for additional imaging as part of the complete interpretative process.

초음파 tomography를 응용한 콘크리트 구조물의 비파괴 시험에 관한 연구 (Application of Ultrasound Tomography for Non-Destructive Testing of Concrete Structure)

  • 김영기;윤영득;윤종열;김정수;김운경;송문호
    • 대한전자공학회논문지SP
    • /
    • 제37권1호
    • /
    • pp.27-36
    • /
    • 2000
  • 본 연구에서는 초음파와 tomography 기법을 기반으로 콘크리트 구조물의 비파괴 시험에 대한 방법론을 정립하고 검증하였다 일반적인 X-ray tomography에서는 물체를 통과하는 파동의 감쇠(attenuation) 데이터에 기초를 두고있는 반면에, 본 연구에서는 time-of-flight(TOF) 데이터를 사용하여 매질의 굴절률(refractive index)을 포괄적으로 표현하는 단층영상을 복원한다 X-ray tomography에서는 측정된 감쇠 데이터를 영상복원(Image reconstruction) 알고리즘에 의해서 처리하며, 파동의 굴절은 고려할 필요가 없다 그러나 초음파는 매질(medium)의 굴절률(refractive index)에 따라 초음파의 경보가 변경되므로 초음파 tomography에서는 초음파 경로의 연산이 선행되어야만 단층영상을 복원할 수 있게 된다 초음파 정보의 연산은 가하광학(Geometrical Optic)에서 사용되는 굴절률과 경로의 관계에 기초를 둔다 영상 복원은 대수학적 접근 방법인 ART (algebraic reconstruction technique) 또는 SIRT(simultaneous iterative reconstruction technique)를 기초로 연산된 초음파의 경로를 따라 선적분한 TOF 값과 측정된 TOF 값의 차이를 기반으로 수행된다 실제 구현에서는 초음파가 직진한다는 가정하에 영상을 복원하고, 이를 기반으로 초음파의 경로를 연산하였다 본 논문에서는 이들 두 과정(경로연산 및 영상복원)의 반복연산을 통하여 영상을 복원하였다. 세안하는 알고리즘을 모의실험으로 평가하였고, 실제 콘크리트 구조물에 적용하여 본 방법론의 무한한 가능성을 입증하였다.

  • PDF

Fractured styloid process masquerading as neck pain: Cone-beam computed tomography investigation and review of the literature

  • Khan, Hassan M.;Fraser, Andrew D.;Daws, Steven;Thoppay, Jaisri;Mupparapu, Mel
    • Imaging Science in Dentistry
    • /
    • 제48권1호
    • /
    • pp.67-72
    • /
    • 2018
  • Historically, Eagle syndrome is a term that has been used to describe radiating pain in the orofacial region, foreign body sensation, and/or dysphagia due to a unilateral or bilateral elongated styloid process impinging upon the tonsillar region. Because elongated styloid processes-with or without associated Eagle syndrome-can present with various symptoms and radiographic findings, it can be challenging for healthcare practitioners to formulate an accurate diagnosis. Abnormal styloid anatomy can lead to a multitude of symptoms, including chronic orofacial/neck pain, thus masquerading as more commonly diagnosed conditions. In this report, we describe a patient who presented to our department with styloid process elongation and fracture. A careful history, physical examination, and a cone-beam computed tomography (CBCT) investigation led to the diagnosis. The patient was then referred for appropriate care. This case report demonstrates the utilization of CBCT in differentiating a fracture site from a pseudo-joint that might mimic a fracture.

초음파를 이용한 부상유적군의 연소기구에 관한 기초연구 (An Elementary Study on the Combustion Mechanism of Levitated Droplet Clusters by Ultrasonic Wave)

  • 정진도;김승모
    • 대한기계학회논문집B
    • /
    • 제27권8호
    • /
    • pp.1191-1199
    • /
    • 2003
  • This paper describes to observe the combustion process of only one droplet cluster. In this study, liquid fuel was atomized by ultrasonic wave to form an acoustically levitated droplet cluster. In order to elucidate the detailed structure of burning process of the droplet cluster, laser tomography method was applied. Time-series planar images of fuel droplets were processed and diameter of the each droplet was calculated based on the Mie-scattering theory. Using these data, the modified droplet group combustion number was estimated in time-series. As the result, when the internal droplet group combustion occur, the modified group combustion number dose not decrease monotonically, but show a tow-staged decreasing process. In all case of combustion process, combustion reactions were measured two types that combustion speed was fast and slow. It was casued by difference of concentration degree and droplet size distribution.

Holographic tomography: hardware and software solutions for 3D quantitative biomedical imaging (Invited paper)

  • Kus, Arkadiusz;Krauze, Wojciech;Makowski, Piotr L.;Kujawinska, Malgorzata
    • ETRI Journal
    • /
    • 제41권1호
    • /
    • pp.61-72
    • /
    • 2019
  • In this paper, we demonstrate the current concepts in holographic tomography (HT) realized within limited angular range with illumination scanning. The presented solutions are based on the work performed at Warsaw University of Technology in Poland and put in context with the state of the art in HT. Along with the theoretical framework for HT, the optimum reconstruction process and data visualization are described in detail. The paper is concluded with the description of hardware configuration and the visualization of tomographic reconstruction, which is calculated using a provided processing path.

A Review of Organ Dose Calculation Tools for Patients Undergoing Computed Tomography Scans

  • Lee, Choonsik
    • Journal of Radiation Protection and Research
    • /
    • 제46권4호
    • /
    • pp.151-159
    • /
    • 2021
  • Background: Computed tomography (CT) is one of the crucial diagnostic tools in modern medicine. However, careful monitoring of radiation dose for CT patients is essential since the procedure involves ionizing radiation, a known carcinogen. Materials and Methods: The most desirable CT dose descriptor for risk analysis is the organ absorbed dose. A variety of CT organ dose calculators currently available were reviewed in this article. Results and Discussion: Key common elements included in CT dose calculators were discussed and compared, such as computational human phantoms, CT scanner models, organ dose database, effective dose calculation methods, tube current modulation modeling, and user interface platforms. Conclusion: It is envisioned that more research needs to be conducted to more accurately map CT coverage on computational human phantoms, to automatically segment organs and tissues for patient-specific dose calculations, and to accurately estimate radiation dose in the cone beam computed tomography process during image-guided radiation therapy.