• 제목/요약/키워드: Pre-qualification Test

검색결과 21건 처리시간 0.028초

초기 단계의 성능분포를 활용한 신뢰성 인증시험의 설계 (Design of Reliability Qualification Test Based on Performance Distribution at the Earlier Stage)

  • 정해성
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제12권3호
    • /
    • pp.131-138
    • /
    • 2012
  • A design of reliability qualification test based on performance distribution is developed. In general, the performance of an item degrades as the time goes by and the failure of an item occurs when the performance degradation reaches the pre-determined critical level. This article considers the reliability qualification test based on a more tightened critical value at the earlier stage to reduce the evaluation testing time and cost. A numerical example is provided to illustrate how to use the developed reliability qualification test.

345kv XLPE절연 케이블의 장기 신뢰성 평가 (Pre-qualification Test on 345kv XLPE Cable and Accessories)

  • 김종원;유인기;김영;이기수;최봉남;윤덕환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1727-1729
    • /
    • 2002
  • To cope with increasing of electric power demand in metropolitan areas, large capacity underground power cables are needed. Under such situations, our company has developed 345kV XLPE insulated cable and accessories. As the final step of development of the 345kV XLPE cable and accessories, the pre-qualification test was carried out on the test line composed of cables, pre-fabricated joints, EB-Gs and EB-As. This paper sums up the pre-qualification test conditions and the results.

  • PDF

성능분포에 기초한 신뢰성 인정시험 설계 (Design of Reliability Qualification Test based on Performance Distribution)

  • 권영일
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제10권1호
    • /
    • pp.1-9
    • /
    • 2010
  • In general, the performance of a component degrades as time goes by and failure of a component occurs when the performance degradation reaches a pre-specified level. It is difficult to obtain the failure time distribution data or the necessary number of failure data especially for the metal or machine part. Thus, a design of reliability qualification test based on performance distribution is more effective than failure time distribution. In this study, a performance-based reliability qualification test is developed and a numerical example is provided to illustrate the use of the developed reliability qualification test. This approach could be applied to many kinds of metal or machine part whose magnitude of strength could not be evaluated during at any random points but judgement can be made by only failure of the part. Besides, it is also possible that any parts which have a similar failure characteristics could be applicable to the developed reliability qualification test.

가스절연송전선로(GIL) PQ시험 방안에 관한 연구 (A Study on the Method of Performance Qualification Test for GIL)

  • 박흥석;한상옥
    • 전기학회논문지
    • /
    • 제60권5호
    • /
    • pp.1062-1067
    • /
    • 2011
  • As the expension of metropolis and increasing of housing site, GIL(Gas Insulated Line) comes to the fore as an alternative to overhead transmission line avoided by local resident. The certification and experimental test for the GIL is now in progress in under ground test lab, Go-chang. For the test, we propose a method of PQ(pre-qualification) test which is essential for development and field application in this paper. The test following this method take about 200 days or 300 days under the circumstances.

우주환경을 고려한 정지궤도위성에 적합한 X대역 필터의 멀티팩터 시험 결과 연구 (The Multipactor Test results on the X Band filter of Space Qualification Model appropriated for the Geostationary Satellite considering for space environments)

  • 박종희;김영길
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국정보통신학회 2017년도 춘계학술대회
    • /
    • pp.65-68
    • /
    • 2017
  • 본 논문은 정지궤도위성 관측탑재체 고속 데이터 전송을 위한 X-대역 이중모드 고전력 채널필터의 우주인증모델에 대한 멀티팩터 시험을 통하여 설계시 요구되는 8 dB 마진과의 비교 검토를 수행하였다. 해석적인 요구되는 마진을 시험을 통해서도 충족하며, 만족한 시험결과를 얻었음을 확인하였다. 멀티팩터의 설계 및 시험은 ECSS의 규격을 준용하여 시험이 실시되었으며, 이를 근간으로 설계시 마진을 충분히 확보되면, 별도의 시험 없이 우주인증 모델용 필터 개발에 있어서 참조하여 사용할 수 있을 것으로 제안한다.

  • PDF

원격조종항공기조종사 적성검사에 관한 연구 (적성검사 항목선정을 중심으로) (A Study on the Aptitude Test of Remotely Piloted Aircraft Pilots (Focused on Selection of Aptitude Test Items))

  • 박원태;이강석
    • 한국항공운항학회지
    • /
    • 제23권1호
    • /
    • pp.30-40
    • /
    • 2015
  • Recently, the need of RPA(Remotely Piloted Aircraft) pilots is increasing rapidly with many requirements in order to be a beginner RPA pilot, including basic flight training, instrument flight qualification training, and aircraft type switching training. When RPA pilot gets disqualified, there will be generated much waste of efforts and expenses of trainees those pilots who are disqualified. Therefore, the methodology of pre-verifying those pilots who are not proper as RPA pilots through various scientific methods will save time and expenses with pre-reducing the pilots who will get disqualified later on. The methodology of aptitude test of RPA pilots is laid out as a consideration of pre-study of RPA pilots work analysis, and select types of aptitude test. A suitability of aptitude test is verified. In order to diagnose the flight aptitude precisely, it requires to be developed. Flight aptitude test tools might be connected with training program which could foster piloting aptitude with pre-diagnosing RPA pilot trainee selecting process. For that reason, we made an experiment in order to verify credibility and suitability of these selected programs with developing RPA pilot aptitude test tools. And also, we analyzed relationships among characteristics, analysis of data, and variables to verify the efficiency of data from prior experiment. Through this thesis, we expect to raise efficiency of flight training by providing pre-flight aptitude test information of RPA pilots.

거주자 사용성 확보를 위한 콘크리트 맨바닥 시공 품질 관리 기법 (Quality Control Techniques for Bare Concrete Floor Construction to Ensure Serviceability for Occupants)

  • 목지욱;최경석;김정진;석원균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.19-20
    • /
    • 2023
  • The pre-qualification system related to floor impact noise is considered ineffective, and thus, the introduction of a post-verification system is being prepared. This is because the performance, which was notarized in the qualification test due to various reasons, was not uniformly confirmed on building construction fields. Industry practitioners perceive that this is due to the influence of factors such as the flatness, levelness and/or thickness of the floor. However, it is very difficult to confirm such facts in a short period of time on the fields, and since the practical application of technology to measure and evaluate quantitatively and the establishment of a system are insufficient, it cannot be said to be a problem that can be brought to the surface. In fact, even when considering the conventional measurement of the dynamic modulus of elasticity, measurements are performed under controlled variables, such as placing a 200mm×200mm buffer material on a flat test-floor. However, in the fields, it is common to lay down larger productions(for example, 900mm×600mm) on the bare floor where significant variables are not controlled, and to construct finishing layers corresponding to the pre-qualified floor system without separately confirming the realization of the dynamic modulus of elasticity in the field conditions. In this study, spatial information of the bare floor on the field was measured and evaluated through a laser scanner. Technical methods for assessing the smoothness, flatness, and thickness of construction surfaces were reviewed, providing key insights for grading the quality of construction based on these criteria. Through further detailed and thorough investigations, it is expected that results suitable for practical application and systematization will be derived.

  • PDF

고온화학세정환경에서 20 % EDTA 용액이 결함 전열관 (Alloy600)에 미치는 영향 (Effect of 20 % EDTA Aqueous Solution on Defective Tubes (Alloy600) in High Temperature Chemical Cleaning Environments)

  • 권혁철
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.84-91
    • /
    • 2016
  • The transport and deposition of corrosion products in pressurized water nuclear reactor (PWR) steam generators have led to corrosion (SCC, denting etc.) problems. Lancing, mechanical cleaning and chemical cleaning have been used to reduce these problems. The methods of lancing and mechanical cleaning have limitations in removing corrosion products due to the structure of steam generator tubes. But high temperature chemical cleaning (HTCC) with EDTA is the most effective method to remove corrosion products regardless of the structure. However, EDTA in chemical cleaning aqueous solution and chemical cleaning environments affects the integrity of materials used in steam generators. The nuclear power plants have to perform the pre-test (also called as qualification test (QT)) that confirms the effect on the integrity of materials after HTCC. This is one of the series studies that assess the effect, and this study determines the effects of 20 % EDTA aqueous solution on defective tubes in high temperature chemical cleaning environments. The depth and magnitude of defects in steam generator (SG) tubes were measured by eddy current test (ECT) signals. Surface analysis and magnitude of defects were performed by using SEM/EDS. Corrosion rate was assessed by weight loss of specimens. The ECT signals (potential and depth %) of defective tubes increased marginally. But the lengths of defects, oxides on the surface and weights of specimens did not change. The average corrosion rate of standard corrosion specimens was negligible. But the surfaces on specimens showed traces of etching. The depth of etching showed a range on the nanometer. After comprehensive evaluation of all the results, it is concluded that 20 % EDTA aqueous solution in high temperature chemical cleaning environments does not have a negative effect on defective tubes.

원자력발전소 적용 고밀도 폴리에틸렌 배관의 맞대기 융착절차 및 검증절차 분석 (Butt-fusing Procedures and Qualifications of High Density Polyethylene Pipe for Nuclear Power Plant Application)

  • 오영진;박흥배;신호상
    • Journal of Welding and Joining
    • /
    • 제31권6호
    • /
    • pp.1-7
    • /
    • 2013
  • In nuclear power plants, lined carbon steel pipes or PCCPs (pre-stressed concrete cylinder pipes) have been widely used for sea water transport systems. However, de-bonding of linings and oxidation of PCCP could make problems in aged NPPs (nuclear power plants). Recently at several NPPs in the United States, the PCCPs or lined carbon steel pipes of the sea water or raw water system have been replaced with HDPE (high density polyethylene) pipes, which have outstanding resistance to oxidation and seismic loading. ASME B&PV Code committee developed Code Case N-755, which describes rules for the construction of buried Safety Class 3 polyethylene pressure piping systems. Although US NRC permitted HDPE materials for Class 3 buried piping, their permission was limited to only 10-year operation because of several concerns including the quality of fusion zone of HDPE. In this study, various requirements for fusion qualification test of HDPE and some regulatory issues raised during HDPE application review in foreign NPPs are introduced.

사전검수 영역기반 정합법을 활용한 영상좌표 상호등록 (Automated Image Co-registration Using Pre-qualified Area Based Matching Technique)

  • 김종홍;허준;손홍규
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2006년도 춘계학술발표회 논문집
    • /
    • pp.181-185
    • /
    • 2006
  • Image co-registration is the process of overlaying two images of the same scene, one of which represents a reference image, while the other is geometrically transformed to the one. In order to improve efficiency and effectiveness of the co-registration approach, the author proposed a pre-qualified area matching algorithm which is composed of feature extraction with canny operator and area matching algorithm with cross correlation coefficient. For refining matching points, outlier detection using studentized residual was used and iteratively removes outliers at the level of three standard deviation. Throughout the pre-qualification and the refining processes, the computation time was significantly improved and the registration accuracy is enhanced. A prototype of the proposed algorithm was implemented and the performance test of 3 Landsat images of Korea showed: (1) average RMSE error of the approach was 0.436 Pixel (2) the average number of matching points was over 38,475 (3) the average processing time was 489 seconds per image with a regular workstation equipped with a 3 GHz Intel Pentium 4 CPU and 1 Gbytes Ram. The proposed approach achieved robustness, full automation, and time efficiency.

  • PDF