• Title/Summary/Keyword: Power-feeding

Search Result 413, Processing Time 0.023 seconds

Behaviour Analysis of Self Excited Induction Generator Feeding Linear and No Linear Loads

  • Moulahoum, Samir;Kabache, Nadir
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1371-1379
    • /
    • 2013
  • Application of induction machines in wind turbine driven generators is a good alternative due to their good characteristics such as efficiency, reliability and low cost. Nevertheless, when isolated operation is required, the application of external capacitive bank, connected to the stator windings, to provide self-excitation results in a rather complex analysis. This paper presents an analysis of self-excited induction generator connected to a load either directly or by an intermediate of a power converter. At first a dynamic model of the induction generator accounting for magnetic saturation is developed. Then a number of balanced and unbalanced capacitors, passive and active loads are verified. Experimental results obtained from laboratory tests are compared to those simulated; the two are shown to be in good agreement.

The Design of a K-Band 4$\times$4 Microstrip Patch Array Antennas with High Directitvity (고지향성 구현을 갖는 K-밴드 4$\times$4 마이크로스트립 패치 어레이 안테나의 설계)

  • Lee, Ha-Young;Kim, Hyeong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.1
    • /
    • pp.161-166
    • /
    • 2007
  • In this paper, two 4$\times$4 rectangular patch array antennas operating at 20 GHz are implemented for the satellite communication. The sixteen patch antennas and microstrip feeding line are printed on a single-layered substrate. The design goal is to achieve high directivity and gain by optimizing design parameters through permutations in element spacing. The spacing between the array elements is chosen to be 0.736$\lambda$. Numerical simulation results indicate that the HPBW(Half-Power Beam Width) of the 4$\times$4 patch array antenna is 18.78 degrees in the E-plane and 18.48 degrees in the H-plane with a gain of 17.18 dBi. Numerical simulations of a 4$\times$4 recessed patch array antenna yield a HPBW of 18.71 degrees in the E-plane and 17.82 degrees in the H-plane with a gain of 19.43 dBi.

Start-up Analysis and Commissioning Test of LCI System for 183MW Large Synchronous Machine (183MW 대용량 동기기 구동 LCI 시스템 기동운전 분석 및 시험)

  • Ryu, Hoseon;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.626-631
    • /
    • 2013
  • Gas turbine systems are applied extensively in energy supplies to cover peak load requirements. The gas turboset must be accelerated by starting device up to 60%~80% of rated speed to ignite the gas turbine. Recently, the most favorable and economical starting device is the LCI(Load Commutated Inverter). The LCI runs up the gas turboset by feeding the generator as a synchronous motor. In this paper, we discuss in detail the driving principles and features of 183MW gas turbine system. During field application of LCI system, many tests have been conducted and the results were described in this paper. The test results will be considered as the important resources for development in future.

A Study on the Application of TEO and STFT Signal Processing Techniques for Detection of Electric Railway Contact Loss (전기철도차량 이선 현상 검측을 위한 TEO 및 STFT 신호처리기법 적용에 관한 연구)

  • Jung, No-Geon;Park, Chul-Min;Lee, Jae-Bum;Park, Young;Shin, Seung-kwon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.11
    • /
    • pp.1530-1535
    • /
    • 2018
  • In this paper, A technique for detecting contact loss at the input power of a railway vehicle has been studied when the contact loss occurs in the feed system. The impedance of the actual railway line was applied to the modeling of the feed system, and modeling was performed based on the performance of the electric railway vehicle. The input voltage and current of the railway vehicle through modeling were analyzed by applying TEO and STFT signal processing technique.

A Study on the Improvement for EMU Maintenance System of Urban Transit (도시철도 전동차 유지보수체계의 개선에 관한 연구)

  • Kim, Kyu-Joong;Lee, Keun-Oh
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.87-92
    • /
    • 2010
  • Urban transit system must secure fast, safe and reliable transportation capacity as a metropolitan mass transit. For this purpose, it is important to make all the sub-systems (which consist of EMU, power feeding, signaling & telecommunication, railway, platform facility, and control system and so on) work well. To operate all the systems effectively and reliably, a maintenance measure optimal to each system's characteristics is needed to be established and executed. So, highly reliable maintenance should be performed. But, EMU maintenance methods suitable to its own model and EMU lines are not yet introduced. This study examined few examples mainly to secure reliability on a maintenance quality in operating method and the features of train maintenance system based on travel distance.

Harmonic Current Reference Generation of Single-Phase Active Filter for the Converter-Fed Locomotives (고속전철용 단상능동필터의 기준고조파전류 발생 방법)

  • Sung, Gi-Seok;Song, Joong-Ho;Choi, Ik;Choi, Ju-Yeop;Kim, Gwang-Bae;Kim, Kwon-Ho;Lim, Myo-Taek
    • Proceedings of the KIPE Conference
    • /
    • 1999.07a
    • /
    • pp.338-341
    • /
    • 1999
  • PWM controlled line-side converters of modern ac traction locomotives inject harmonic currents into the feeding overhead line. This causes problem of electromagnetic interference. Passive and Active filters are usually provided for a reduction of the line harmonics. Active filters are more reasonable than passive filters in terms of weight and space of the filters. Successful control of active filters requires an accurate harmonic current reference. A technique to generate the harmonic current reference is proposed in this paper. The analysis is performed in frequency domain and its effectiveness is verified by simulation.

  • PDF

KSR-III Integration Power Plant Test Using PTA-II Test Facility (PTA-II 시험설비를 활용한 KSR-III Rocket 추진기관 종합시험)

  • 강선일;권오성;이정호;김영한;하성업;오승협;이수용
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.193-196
    • /
    • 2003
  • The KSR-III developed by KARI is the first rocket vehicle which is adopting the liquid propellant rocket engine system in Korea and its flight test was successfully done last year. KSR-III is a sounding rocket class launch vehicle, but there is a sense to accomplish design, manufacture, performance test and finally its flight test by domestic technology. In this paper, the authors are intended to introduce the multi-purpose test facility(PTA-II Test Facility) which is constructed for the variety of tests on KSR-III feeding system(single component tests, verification tests, cold flow tests and combustion tests) and its test results.

  • PDF

Reduction of Power Dissipation by Switching Activity Restriction in Pipeline datapaths (파이프라인 데이터경로에서의 스위칭 동작 제한을 통한 전력소모 축소)

  • 정현권;김진주;최명석;김동욱
    • Proceedings of the IEEK Conference
    • /
    • 1999.06a
    • /
    • pp.381-384
    • /
    • 1999
  • In this paper, we addressed the problem of reducing the switching activity in pipeline datapath and proposed a solution. clock-gating method is a kind of practical technique for reducing switching activity in finite state machine. But, in the case that the target gated function unit has a pipeline structure, there is some spurious switching activity on each stage register group. This occur in early stage of every function enable cycle. In this paper we proposed a method to solve this problem. This method generates the enable signal to each pipeline stage to gate the clock feeding register group. Experimental results showed effective reduction of dynamic powers in pipeline circuits.

  • PDF

Study on the effective earthing method in underground section of railways (철도 지하구간에 대한 효율적인 접지방안에 대한 연구)

  • Kim Yang-Soo;Kim Jae-Moon
    • Proceedings of the KSR Conference
    • /
    • 2005.05a
    • /
    • pp.767-775
    • /
    • 2005
  • Power Supply System for electric railways is diversified with technical development and is required high technologies. especially, recently there is required many research and development for earthing to ensure safety of people and protection of installations. Generally, leakage resistance is high between rail and ground at tunnel section of subway. because of short circuit of feeding line, earthing interference by transient overvoltage between signals and communication system, and insulation failure, it can damage to human and equipments To minimize these obstacles, earthing equipment is installed at underground section of railway, but it brings about problems in accordance with operate each earthing system to be not enough required protection provisions for electrified railways. This paper proposes effective earthing method to be concerned about installation cost and maintenance. The validity of the proposed earth method is verified by simulation results at underground section of railways.

  • PDF

Study for Charge-Discharge Auto Level-Tuning Algorithm of Energy storage system (에너지저장시스템의 충, 방전 Auto Level-Tuning 알고리즘에 관한 연구)

  • Baek, Seoung-Gil;Lim, Ji-Young;Cha, Joon-Il;Kim, Kil-Dong;Kwon, Kyoung-Min
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.514-520
    • /
    • 2010
  • This paper is about control algorithms that bi-direction DC-DC Converter using Super Capacitor and regenerative power from DC feeding system in train. In order to take advantage of regenerative energy efficient, charge and discharge level value of energy storage system serve as an important factor. Respect to output fluctuations of the substation and catenary voltage changing, we offers Charge-Discharge Auto Level Tuning Algorithms to improve system following of Energy Storage System.

  • PDF