• Title/Summary/Keyword: Power system construction

Search Result 1,650, Processing Time 0.035 seconds

A Study on the DC to DC Converter to Improve the Performance of Power LED System (파워 LED 시스템 성능개선을 위한 DC/DC 컨버터에 관한 연구)

  • Kim, Young Tae;Kim, Sei Yoon
    • Journal of Drive and Control
    • /
    • v.19 no.4
    • /
    • pp.85-90
    • /
    • 2022
  • In this paper, a DC converter to improve the performance of Power LED system is discussed. The mathematical model of PWM converter power stage using 3-Terminal PWM cell is introduced for power LED system. A controller for DC converter system is used as a self-tunning regulator with a recursive least-squares algorithm. Minimum variance control method is used as a control law. Experiment results verified that proposed control system could improve the performance of Power LED system.

A study on activation plan of development of the advanced construction technology (건설신기술 개발의 활성화 방안에 관한 연구 - 전문건설업체를 중심으로 -)

  • On Seong-Won;Park Hyeon-Yong;Lee Young-Hwan;Woo Sungkwon
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2004.11a
    • /
    • pp.490-493
    • /
    • 2004
  • The domestic construction industry need to do productivity improvement through technology development than improvement of manpower control or system and develop competitive power through technology in international construction market. Upon this, government for elevation of technological level enacts and operates the advanced construction technology endorsement system but is not looking at effect as that the actual use-results also expected first. Therefore, in this paper, present improvement and direction for activation plan of construction new technology development through comparison with other connection system, literature investigation and questionnaire after grasp present condition of the advanced construction technology endorsement system with specialty construction company as the central figure which occupy most of appointed new technology.

  • PDF

Life-Cycle Analysis of Nuclear Power Plant with Seismic Isolation System (면진장치 적용을 고려한 원전구조물 생애주기 분석)

  • Kim, Sunyong;Lee, Hong-Pyo;Cho, Myung-Sug
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.26 no.6
    • /
    • pp.415-421
    • /
    • 2013
  • In order to extend the service life of a nuclear power plant(NPP) ensuring the structural safety, effective and efficient management of NPP considering structural deteriorations and various natural hazard risks has been treated as a significant tool(IAEA 1998). The systemic efforts is required to prevent the potential loss of NPPs resulting from the natural hazard including earthquakes, hurricane and flooding since the Fukushima accident. Earthquake risk of building structures can be mitigated through appropriate seismic isolation system installation. It has been known that a seismic isolation system can lead to reduction of the deleterious effect on ground motion induced by earthquakes, and structural safety can be improved. In this paper, the NPP life-cycle management is reviewed. Furthermore, effect of seismic isolation on the NPP life-cycle cost analysis with earthquake, and cost-benefit analysis in terms of life-cycle cost when applying the seismic isolation systems to NPP are introduced.

The analysis of inductive contactless inductive power transformer used for the PRT(Personal Rapid Transit) system (소형궤도 차량 시스템에 적합한 무접촉 유도 전력 변환 장치의 특성해석)

  • Han, K.H.;Lee, B.S.;Byun, Y.S.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2004.10a
    • /
    • pp.218-220
    • /
    • 2004
  • In this paper, the concept of contactless inductive power transfer system used for the PRT system is suggested and some ideas for Power transformer design to improve the power transfer performance are presented. This system has a large air-gap and demands a large electrical power capability But, low output power is generated due to a loosely coupled characteristic of the large air-gap. Therefore, double layer construction of secondary winding, which was divided in half to increase both output current and output voltage was suggested. In addition, the performance of power transformer alignment condition between the primary power line and the power collector was verified by computer simulation of 2kW model.

  • PDF

The Characteristic of Wind Turbine Industry of the West-South Seashore of Leading Industry Development for Honam Economic Region (호남광역경제권의 서남해안 풍력산업 특성)

  • Cha, In-Su;Kim, Tae-Hyung;Lee, Ki-Bong
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.101-102
    • /
    • 2010
  • This paper represents about the characteristics of wind turbine industry of the west-south seashore of Leading Industry Development for Honam Economic Region. These projects have 8 R&D and 3 non R&D project. The period of these projects is from October 2009 to April 2012. The R&D projects are composed three bright prospect products (1) the base construction of MW off-shore wind turbine components and system with Outer-rotor type PMSG, (2) the Development of 3MW wind power system with accommodation of the west-south seashore, and (3) the development of hybrid wind turbine system with wind base construction. Also, the non-R&D projects are composed three parts with above three bright prospect products. Above two projects support the companies with characteristic of low speed wind turbine system. Other project supports the companies related to wind turbine with small and medium capacity of form 3 kW to 10kW.

  • PDF

Development of real-time wireless data measurement technique on Centrifugal experiment (원심모형 실험기의 실시간 무선데이터 측정시스템 구축)

  • Lee, Jong-Pil;Kim, You-Seok;Park, Jin-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09a
    • /
    • pp.1289-1293
    • /
    • 2010
  • A slipring or FORJ are usually adopted in order for power supply of Geo-centrifuge and input/output data acquisition. Since using slipring causes quite a lot electrical noise, an optical communication using FORJ becomes more general for data acquisition. Such data acquisition devices, however, require frequent maintenance and replacement due to deterioration by long term usage. DICT has set up a real-time wireless date acquisition system using wireless communication technology instead of FORJ. The system enables a remote measurement at any inertial acceleration field up to 100g level and provides as same performance as FORJ. The priority of this system is to use a normal modem substituting a special FORJ.

  • PDF