• Title/Summary/Keyword: Power line

Search Result 6,044, Processing Time 0.037 seconds

A Study on Power System Decomposition Technique for Digital Simulation of Large Power System (대규모 계통의 디지털 시뮬레이션을 위한 계통분할 기법이 관한 연구)

  • Lee, Chul-Kyun;Lee, Jin;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.171-173
    • /
    • 2002
  • This paper presents a power system decomposition technique for digital simulation of large power system. To decompose power system, distributed transmission line model is used. But this model can be used only for long transmission lines. In this paper, capacitor compensation method is proposed to use distributed transmission line model for short transmission line. And case study shows proposed method can be used for effective power system decompositon in digital simulation of large power system.

  • PDF

Cable Identification Technology based on Power Line Communication (전력선 통신을 활용한 케이블 식별 기술)

  • Byun, Hee-Jung;Choi, Sang-jun;Shon, Sugoog
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.880-883
    • /
    • 2015
  • Power-line communication technology is proposed to identify cables of power distribution systems. It can extend the application area of power-line communication. Distribution line cable circuits have only a limited ability to carry higher frequencies. Typically power transformers in the distribution system prevent propagating the higher frequency carrier signal. The proposed method uses the limited propagation ability to identify the cable. A novel power cable identification system is designed and implemented. The system consists of a transmitter and a receiver with power-line communication module. Some experiments are conducted to verify the theoretical concepts. Also some simulations are done to help and understand the concepts by using Simulink simulator.

  • PDF

A study on transient stability of 345 KV power transmission line (345KV 송전선의 과도안정도계산 I)

  • 이재숙
    • 전기의세계
    • /
    • v.18 no.1
    • /
    • pp.24-29
    • /
    • 1969
  • This is preliminary study concerning the future construction and operation of 345KV power transmission line in Korea which will be added to the existing 161KV power system by the end of 1970 in order to increase the power carrying capacity between Seoul and Pusan area; 350 kilo meters aparts, in accordance with the ambitious second five years power development schedule of Korea Electric Company. The result of this study says that an intermidiate switching station should be installed at the middle position of the line to improve the transient stability of the system, considerable amount of capacitors or synchronous condenser are to be installed to reduce the voltage drop at receving end of line during the heavy load hours, and also in some measure to avoid the voltage rise by self-excitation of power generators during the light load hours and while energizing the line. This is the first attempt to realize the EHV power transmission line in Korea so that the additional study is necessary on the kind and size of conductors, the necessary number of insulators and the suitable clearance distances between conductor and steel tower or earth from the technical and economical view points. These are necessary steps to be taken by the writer before getting into the calculation on the transient stablity of the power system.

  • PDF

A Fundamental Study for Establishment of Channel Data Base in Power-Line Communications (전력선 통신 채널 Data Base 구축을 위한 기본 연구)

  • Oh Hui-Myoung;Kim Kwan-Ho;Lee Won-Tae;Lee Jae-Jo
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.2
    • /
    • pp.107-111
    • /
    • 2003
  • In the power-line communication systems, there are many factors of noise and attenuation in the power-line channels, because they were designed for not the communication but the power transmission. Also the transfer function of the channels is highly changed with the topology and the load of the power-lines. To cope with these poor channel situation, channel modeling, one of the many studies in progress, is being studied hard. Channel modeling is essential to apply the active schemes to overcome the bad channel(e.g. modulation technique, channel coding, signal coupling & filtering, etc.) to the power-line communications. In this paper, we have realized the statistical model(this model is suggested as the channel modeling method for the power-line channels) that is combined the transfer function with the various noises. And we have compared and examined the results with the measured data. Also we have studied the plan which can effectively establish the channel data base for the channel information consisted of the parameters that are derived from this modeling, and we have studied the plan to utilize the data base.

A Study on the internet performance analysis that use PLC (PLC를 이용한 인터넷 성능 분석에 관한 연구)

  • Nam, Tae-Hee
    • Journal of the Korea Computer Industry Society
    • /
    • v.8 no.4
    • /
    • pp.245-252
    • /
    • 2007
  • This treatise wishes to estimate internet performance using PLC(Power Line Communication) instead of use existing exclusive line. Hard problem of many communication network mountings and work does solution low class informer with power line simply. If use net by power line with this, can get into enormous gains in side of early expense as well as hard problem of work. This treatise investigated validity about if investigate using power line what level internet utilization can take advantage of, and can activate internet by hereafter first term.

  • PDF

Calculation of Reclosing Dead Time of 500 kV Horizontal Single Circuit Transmission Line (500 kV 수평배열 1회선 송전선로의 재폐로 무전압시간 산정)

  • Shim, E.B.;Kwak, J.S.;Joo, H.J.;Park, H.S.;Kang, Y.W.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.641-643
    • /
    • 2005
  • It is usual to operate the long transmission line with transposition of each phase in order to avoid voltage unbalance due to unbalanced capacitances at each phase of the line end. This paper described the Ferranti voltage rise of line end, charging current and secondary arc current according to the transposition of line or not. The positive and negative sequence current was derived by the phase current, and then the unbalanced rate was calculated. Then, we obtained the reclosing dead time of the single phase reclosing scheme for 500 kV single circuit horizontal arrangement transmission line system.

  • PDF

Power Line Modelling and Case Study for Indoor Power Line Network Analysis (옥내 전력선망 분석을 위한 전력선 모델링과 사례 연구)

  • Kim, Won-Ho;HwangBo, Hoon;Nah, Wan-Soo;Park, Il-Han;Kim, Byung-Sung;Kim, Chang-Seob
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2324-2326
    • /
    • 2005
  • For the analysis of domestic Indoor power line network, we defined parameters of transmission line and simulated it. We conducted the case study which shows the general characteristics of KSC3302 power line. We will develop software for indoor power line network analysis.

  • PDF

Height & Position Control of a Power Line Inspection Robot Using Various Sensors (다양한 센서를 이용한 배전선 점검 로봇의 높이 및 자세제어)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.2
    • /
    • pp.169-175
    • /
    • 2009
  • A new wire detection algorithm for power line inspection by a mobile robot has been proposed in this paper. There have been a lot of studies in order to support the high-quality electric power. For the high-quality power supply, it is necessary to investigate the power lines and insulators before the lines or insulators were disconnected or damaged. Although Korea Electric power Corp. has made many efforts for the quality improvement, it is not enough to inspect all the power lines by human inspectors. According to this problem, it is decided to replace the human operators by the power line inspection robot. When the robots are used for the inspection, there could be several advantages, for example, the working efficiency and the prevention of accident. And also the shortage of human power for dangerous jobs can be resolved. In this paper, as a part of the development of power line inspection robot, DICRO, the sensor fusion and fuzzy control algorithms are developed to detect the wire and slope of the wire. The effectiveness of the proposed algorithms is proved by the real experiments with DICRO which is under development so far.

Dynamic Characteristic of the Superconducting Cable in unbalanced Faults (불평형 고장시의 초전도 케이블의 응동 특성)

  • Lee, Geun-Joon;Lee, Jong-Bae;Hwang, Si-Dol
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.37-39
    • /
    • 2007
  • In the faults of power line, single line ground and line-to-line fault make power system to unbalanced. These fault currents make unbalanced power system. This paper suggests the simulation results of dynamic characteristic of HTS cable system under unbalanced faults condition using EMTDC, Quench phenomenon and current limiting effects are observed. However, quench on the HTS is destroy cable system, coordination with SFCL has to be considered.

  • PDF

DEVELOPMENT OF SIMULATOR FOR POWER LINE COMMUNICATION CHANNEL (전력선 통신 채널의 시물레이터 개발)

  • Park, Chong-Yeun;Jung, Dong-Youl
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3114-3116
    • /
    • 1999
  • We have developed the power line simulator which is one of the basic tools for the research of the power line communication and the control system. In the developed simulators, we have considered the transfer characteristics of the power line, various noise characteristics, and signal attenuation characteristics.