• Title/Summary/Keyword: Power 함수

Search Result 1,476, Processing Time 0.026 seconds

A Proposal of Reference Power Spectral Density Functions Compatible with Highway Bridge Design Specta (도로교 내진설계 스펙트럼에 부합하는 표준 PSD함수의 제안)

  • Choi, Dong Ho;Lee, Sang Hoon;Koh, Jung Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.1A
    • /
    • pp.59-67
    • /
    • 2008
  • Acceleration time history used in the seismic analysis of nuclear power plant structures should envelop a target power spectral density (PSD) function in addition to the design response spectrum in order to have sufficient energy at each frequency for the purpose of ensuring adequate load. The safety for complex long-span highway bridges cannot be over-emphasize. An alternative method to improve the seismic capacity is to ensure the minimum PSD function of the applied seismic load. This study proposes a technical scheme to obtain the reference power spectral density function by using artificial earthquakes which are compatible with the highway bridge design spectrum.

A DSP Based Active Power Filter with Instantaneous Correlation Power Theory (상관함수에 의한 순시전력이론을 이용한 DSP 능동전력필터)

  • 정영국;임영철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.50-56
    • /
    • 1999
  • This paper presents consideration on validity of instantaneous correlation power theory. The proposed power theory is defined and analyzed by time domain approach, thus it is easy to understand and instrument. The power is decomposed into active, fundamental reactive and harmonics components based on the autocorrelation and crosscorrelation signal techniques between voltage and current waveforms. On the compensation property, active power filter deal with three components only. Also, for real time control of active power filter, the power models with difficult concept are not cost effective. To verify the validity of the instantaneous correlation power theory, experimental work for voltage type DSP based active power filter is achieved. The power of thyristor controlled motor drives is decomposed into three orthogonal components by proposed power theory. From compensation results, validity of proposed theory is confirmed. feedback controller needs the information on some motor parameters. New recursive adaptation algorithms for rotor resistance and mutual inductance which can be applied to our nonlinear feedback controller are also presented in this paper. The recursive adaptation algorithms make the estimated values of rotor resistance and mutual inductance track their real values. Some simulation and experimental results show that the adaptation algorithms are robust against the variation of stator resistance and stator inductance.

Analysis on Power Consumption Characteristics of SHA-3 Candidates and Low-Power Architecture (SHA-3 해쉬함수 소비전력 특성 분석 및 저전력 구조 기법)

  • Kim, Sung-Ho;Cho, Sung-Ho
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.1
    • /
    • pp.115-125
    • /
    • 2011
  • Cryptographic hash functions are also called one-way functions and they ensure the integrity of communication data and command by detecting or blocking forgery. Also hash functions can be used with other security protocols for signature, authentication, and key distribution. The SHA-1 was widely used until it was found to be cryptographically broken by Wang, et. al, 2005. For this reason, NIST launched the SHA-3 competition in November 2007 to develop new secure hash function by 2012. Many SHA-3 hash functions were proposed and currently in review process. To choose new SHA-3 hash function among the proposed hash functions, there have been many efforts to analyze the cryptographic secureness, hardware/software characteristics on each proposed one. However there are few research efforts on the SHA-3 from the point of power consumption, which is a crucial metric on hardware module. In this paper, we analyze the power consumption characteristics of the SHA-3 hash functions when they are made in the form of ASIC hardware module. Also we propose power efficient hardware architecture on Luffa, which is strong candidate as a new SHA-3 hash function. Our proposed low power architecture for Luffa achieves 10% less power consumption than previous Luffa hardware architecture.

Low-Power Bus Driven Floorplan for Segmented Bus Design (버스 분할 설계를 위한 저전력 버스 기반 평면계획)

  • Yoo, Jae-Min;Rim, Chong-Suk
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.10 s.352
    • /
    • pp.134-139
    • /
    • 2006
  • In this paper we present the Low-Power Bus Driven Floorplan(BDF) in which the bus power consumption is minimized by using a new cost function. The previously reported BDF has used the cost function which minimizes only the chid and the bus area. However, such a cost function may not consider the bus power consumption determined by the topology of a bus in case of the segmented bus design. In this paper, we formulate a new cost function which. reflects the communication frequency and the real distance between blocks in a bus to model the bus power consumption. For the Low-Power BDF with the new cost function, the experimental results show the bus power consumption cost is reduced by 11.43% on the average.

A Study on BTEX Removal Efficiency for Variation of Moistures by Microwave Process (유류오염토의 마이크로파 처리 시 토양의 함수율 변화에 따른 BTEX 제거특성에 관한 연구)

  • Ha, Sang-An;Yeom, Hae-Kyong;Yu, Mi-Yong
    • Journal of Soil and Groundwater Environment
    • /
    • v.12 no.2
    • /
    • pp.65-71
    • /
    • 2007
  • This study has been focused on an application of microwave pre-treatment of soil contaminated with volatile organic chemicals, and BTEX(benzene, toluene, ethylene, xylene). Microwave experiments were carried out under different power conditions (2 kW, 4 kW) using different moisture contents and BTEX concentration. According to these results of this study, the most BTEX removal efficiency was with 20% moisture contents regardless of electric power. The result show that 2kW was determined to the optimum electric power at $10{\sim}30%$ moisture contents, but the optimum power was 4 kW at 50% of moisture content.

Analysis of runoff aggregation structure and energy expenditure pattern for Choyang creek basin on the basis of power law distribution (멱함수 법칙분포를 기반으로 한 조양하 유역의 유출응집구조와 에너지소비 양상에 대한 해석)

  • Kim, Joo-Cheol;Cui, Feng Xue;Jung, Kwan Sue
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.11
    • /
    • pp.725-734
    • /
    • 2017
  • The main purpose of this study is to analyze runoff aggregation structure and energy expenditure pattern of Choyang creek basin within the framework of power law distribution. To this end geomorphologic factors of every point in the basin of interest, which define tractive force and stream power as well as drainage area, are extracted based on GIS, and their complementary cumulative distributions are graphically analyzed through fitting them to power law distribution. The results indicate that three distinct behavioral regimes are observed from the complementary cumulative distributions of three geomorphogic factors. Based on the parameter estimation of power law distribution by maximum likelihood drainage area and stream power can be judged as scale invariance factor without finite scale while tractive force as scale dependence factor with finite scale. Furthermore, it is judged that tractive force would not follow power law distribution because it shows limited complex system behaviors only within the small extent of scale. The exponent of power law distribution for drainage area obtained in this study by maximum likelihood is larger than the previous researches due to the difference of parameter estimation methodologies. And the exponent for stream power is smaller than the previous researches due to the scaling property of channel slope for the basin of interest.

Analysis of drainage structure for river basin on the basis of power law distribution (멱함수 법칙분포를 기반으로 한 유역의 배수구조에 대한 해석)

  • Kim, Joo-Cheol;Kang, Heeseung;Jung, Kwansue
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.6
    • /
    • pp.495-507
    • /
    • 2016
  • This study aims at hydrologically demonstrating the universality of power law distribution by analyzing runoff aggregation structures of river basins. Power law distribution is fitted to cumulative drainage area of basins of interest by maximum likelihood, which results in the power law exponents. And then those exponents are assessed in terms of the shape of catchment plan-form. As a main result all of the basins in this study have similar distributions of catchment area. The exponents from this study tend to be higher than the ones from previous researches reflecting self-similar property of the catchment plan-forms of interest. Further study is required about the universality of power law distribution by means of the more realistic flow routing scheme within the framework of DEM.

Estimation and Analysis of the Vertical Profile Parameters Using HeMOSU-1 Wind Data (HeMOSU-1 풍속자료를 이용한 연직 분포함수의 매개변수 추정 및 분석)

  • Ko, Dong-Hui;Cho, Hong-Yeon;Lee, Uk-Jae
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.33 no.3
    • /
    • pp.122-130
    • /
    • 2021
  • A wind-speed estimation at the arbitrary elevations is key component for the design of the offshore wind energy structures and the computation of the wind-wave generation. However, the wind-speed estimation of the target elevation has been carried out by using the typical functions and their typical parameters, e.g., power and logarithmic functions because the available wind speed data is limited to the specific elevation, such as 2~3m, 10 m, and so on. In this study, the parameters of the vertical profile functions are estimated with optimal and analyzed the parameter ranges using the HeMOSU-1 platform wind data monitored at the eight different locations. The results show that the mean value of the exponent of the power function is 0.1, which is significantly lower than the typically recommended value, 0.14. The values of the exponent, the friction velocity, and the roughness parameters are in the ranges 0.0~0.3, 0~10 (m/s), and 0.0~1.0 (m), respectively. The parameter ranges differ from the typical ranges because the atmospheric stability condition is assumed as the neutral condition. To improve the estimation accuracy, the atmospheric condition should be considered, and a more general (non-linear) vertical profile functions should be introduced to fit the diverse profile patterns and parameters.

Optimization of Economic Load Dispatch Problem Using Linearly Approximated Smooth Fuel Cost Function (선형 근사 평활 발전 비용함수를 이용한 경제급전 문제의 최적화)

  • Lee, Sang-Un
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.3
    • /
    • pp.191-198
    • /
    • 2014
  • This paper proposes a simple linear function approximation method to solve an economic load dispatch problem with complex non-smooth generating cost function. This algorithm approximates a non-smooth power cost function to a linear approximate function and subsequently shuts down a generator with the highest operating cost and reduces the power of generator with more generating cost in order to balance the generating power and demands. When applied to the most prevalent benchmark economic load dispatch cases, the proposed algorithm is found to dramatically reduce the power cost than does heuristic algorithm. Moreover, it has successfully obtained results similar to those obtained through a quadratic approximate function method.

Direct Transient Stability Analysis for Multi-Machine Power Systems by Using Damping-reflected Energy Functions (댐핑영향을 고려한 에너지함수를 이용한 다기계통 과도안정도해석)

  • Lee, Ki-Je;Choi, Byoung-Kon;Kwon, Yong-Jun;Kim, Hyun-Sung;Moon, Young-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.287-290
    • /
    • 2003
  • 다모선 계통의 정확한 과도 안정도 직접해석을 위해 댐핑영향은 고려해야 할 중요한 요소 중의 하나이나 일반화가 어려워 최근까지 무시되어 왔다. 본 논문에서는 시스템을 나타내는 함수들의 적분 관계식들을 고려함으로써 다모선 계통에서의 댐핑영향을 반영한 에너지 함수를 유도하였으며 유도 과정에 있어 최근 다모선 계통에 보편적으로 적용되고 있는 관성중심(Center of Inertia :COI) 표현법으로 전개를 시도하였다. 유도된 에너지함수를 PEBS(Potential Energy Boundary Surface) 직접법에 적용하여 임계위치에너지를 산출하였으며, 임계고장제거시간을 계산함으로써 과도안정도직접해석법을 수행하였다. 제안된 에너지 함수를 WSCC 3기 9모선 샘플 시스템에 적용하여 댐핑이 고려된 에너지함수가 실제 계통을 보다 정확하게 표현하고 있음을 시뮬레이션을 통해 검증하였다.

  • PDF