• Title/Summary/Keyword: Post-PC

Search Result 305, Processing Time 0.029 seconds

Development of Small Package Drop-Off System (PC 기반의 무인 소화물 접수장치 설계에 관한 연구)

  • Nam, Byong-Keun;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.11c
    • /
    • pp.450-452
    • /
    • 2001
  • In this paper, we proposed the automatic postal drop-off system based on the microprocessor board or PC. The weight of the small postal package is transmitted from the electronic scale and user-entered addresses and delivery rate are processed by the controller to calculate the fee. For 24 hour out-door operation and maintenance, non-cash payment methods such as credit card payment is used. The post stamp and receipt are printed by the thermal printer. For the electronic processing of the parcel, serial code is also printed on the stamp and receipts in bar code format. The parcel information obtained by the automatic postal drop-off system is transferred to remote central system by dial-up modem shared by the on site office. The proposed system and its control software are built for prototype model operation and the result met the design requirements. For real time processing, data reception through three serial ports is handled by interrupt routine. The proposed system is expected to be applied for commercial logistics system and pc automation system.

  • PDF

The Pre-Service and Post-Transcoding Method for Enhancing the Response Time of Mobile Web Service (모바일 웹 서비스의 응답시간을 향상시키기 위한 선 서비스 후 변환 방법)

  • Kang, Eui-Sun;Park, Dae-Hyuck;Lim, Young-Hwan
    • The KIPS Transactions:PartD
    • /
    • v.14D no.7
    • /
    • pp.783-790
    • /
    • 2007
  • One of the particulars to be considered for providing wireless web service with PC web page is the hardware environment between PC and mobile device. It is because time cost is required in producing mobile contents to suit environment of the connected terminal. Therefore, server side should take account of response time and disk capacity of server. Response time is delayed by content conversion and disk capacity need to store various versions about one content. This paper suggests a pre-service and post-transcoding method to provide faster response time for a mobile terminal. The pre-service is to minimize response time by placing the top priority in servicing contents saved in cache as much as possible even if the quality of contents serviced to mobile terminal may be low. After pre-service is provided, the mobile content is transcoded for the terminal later. Performance level of method proposed was compared through experiment and the result of analysis was described.

Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands (2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험)

  • Hwang, Jin-Ha;Choi, Seung-Ho;Lee, Deuck Hang;Kim, Kang Su;Woo, Woon Tack
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.33 no.12
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

Seismic Performance of Precast Beam-Column Joints with Thru-Connectors (관통형 연결재로 연결된 PC 보-기둥 맞댐 접합의 내진성능에 관한 실험적 연구)

  • Park, Soon-Kyu;Kim, Min-Hee
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.4
    • /
    • pp.441-450
    • /
    • 2010
  • This is a preliminary study on the development of precast beam-column joints for dry construction methodology. Precast beam column joints with thru-connectors (BCJ_TC) using high strength bars or PS strands were developed and their seismic performance including strength degradation, stiffness degradation and energy dissipation capacity was experimentally evaluated. Test results showed that compressive failures at the end blocks of PC beam members occurred dominantly while PC columns including panel zones were free from any damage. However, the connections confined with CFRP at the end block showed much improved seismic performance than that of the unconfined connections. Connections with neoprene pad fillers between beam and column interfaces were better than the other connections in all the seismic performances except initial stiffness. To improve the seismic performances of BCJ_TC, compressive strength of the concrete at the end block need to be increased to compensate for the additional compressive stresses due to unbonded connectors and deformation of connectors should be controlled respectively.

The Survey of the Characteristics of Educational Environment on Post-Graduate Physical Therapists (졸업 후 물리치료사의 교육환경특성에 대한 조사연구)

  • Hwang, Seong-Soo;Kwon, Hei-Jeoung
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.18 no.2
    • /
    • pp.57-66
    • /
    • 2012
  • Background: The main purpose of this study was to know the educational environment on physical therapists who were working at clinical field after graduation. Methods: The subjects of this study were 241 therapists who took and OMPT or PNF course at Seoul, Incheon and Kyounggido. The data were collected during April to June 2012. The data were analysis by SPSS PC by cross-tab, mean, percentage. Results: The general characteristics of physical therapists who took post-graduate education: female (56.0%), 1-3 years clinical experience (41.5%), 25-29 years old (46.5%). The main reason to take post-graduate educational program was to learn more high quality therapeutic skills for the patients treatment (88.4%). But the condition of environment wes poor such as they pay all of expenses by themselves (54.9%), not permit to take international post-graduate educational program (77.2%). Conclusions : For the better post-graduate educational environment for the physical therapists, it needs systemic plan and sequential strategy with passion for the future.

  • PDF

Reliability Evaluation of EDR Data Using PC-Crash & Vbox (Vbox와 PC-Crash를 활용한 EDR 기록정보의 신뢰성 평가)

  • Park, Jongchan;Kim, Jonghyuk;Oh, Wontaek;Choi, Jihun;Park, Jongjin
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.3
    • /
    • pp.317-325
    • /
    • 2017
  • The EDR(Event Data Recorder) is a part of the ACU(Airbag Control Unit) functions mounted on a vehicle. EDR data have pre-crash data and post-crash data. Pre-crash data are recorded within 5 sec from time zero(AE) with 0.5 sec resolution, and reveal vehicle speed, engine rotation speed, throttle opening, brake pedal operation, acceleration pedal position and steering angle, etc. Using this EDR data, the investigation of a traffic accident can become more objective and scientific. Crash tests of three vehicles equipped with EDR function had been performed successfully. Evaluation of EDR data reliability had also been performed using Vbox and PC-Crash's sequence table function. Based on the results, we could confirm EDR data's reliability and availability for Traffic Accident Analysis by the series of this process.

The Smartware using Concept of Ubiquitous (유비쿼터스 개념을 도입한 스마트웨어)

  • Lee, Jeong-Ick
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.923-928
    • /
    • 2009
  • The advance of scientific technology is enhanced the effect of reaction. The trend of customer for high function product is enlarged. Thus, the composition of each industry, technology and product is actually happened. Therefore, the fusion of different fields in industrial design is widely accomplished. The example of this fusion effect is that 'ubiquitous or wearable computer' which is combined the function of cloth and computing, which is including any type, any purpose, any telecommunication and any multimedia of cloth inside. The ubiquitous or wearable computer will be a final thing of post pc or next step to pc and internet. This paper is studied for the research of smartware by assistance energy. In this paper, the development of multipurpose smartware(wearable computer) powered by solar energy is introduced.

Effects of Acupoint Stimulation at the Pericadium and Liver Meridian on Heart Rate Variability (수족궐음경(手足厥陰經)의 경혈(經穴)이 심박변이도 SDNN에 미치는 영향)

  • Sung, Kang-Keyng
    • Korean Journal of Acupuncture
    • /
    • v.32 no.3
    • /
    • pp.130-135
    • /
    • 2015
  • Objectives : This study is to investigate stimulation effects of acupoints at differential meridian along arm and leg on the physiological phenomenon of heartbeats. Methods : 8 subjects were participated in this study. The experiments were performed in Resting session(Rs), Insertion session(Is), Stimulation session1(Ss1), Stimulation session2(Ss2), Stimulation session3(Ss3) sequence. Time of each session and the interval between each session was 30 seconds all. Acupuncture was performed manually on PC3 or LR8 at random with a two-day interval. stand deviation of N-N interval(SDNN) was measured for each session. Results : At PC3, SDNN increased in Ss1, Ss2, and Ss3 compared to Rs but at LR8, there was little change between Ss1, Ss2, Ss3 and Rs. Post-hoc analysis revealed that mean value of SDNN significantly increased in Ss1 compared with Baseline at PC3, while there was little change at LR8. When LR8 and PC3 were compared at each time point, there was a significant difference only in Ss1. Conclusions : Our results indicate that there is a correlation between specific physiological functions and acupoints.

Post-manufacturing Array Operation Repair for NAND Flash Memories with On-Chip Microcontrollers (온칩 마이크로컨트롤러를 사용하는 낸드 플래시 메모리의 제조 후 어레이 동작 수정)

  • Geonu Kim;Yong-Ho Cho
    • Journal of IKEEE
    • /
    • v.28 no.3
    • /
    • pp.365-368
    • /
    • 2024
  • This paper proposes a scheme for NAND flash memories equipped with on-chip microcontrollers and instruction ROM, that enables patching of erroneous cell array operation instructions after manufacturing. The scheme incorporates a small patch instruction RAM, where the patching instructions are fetched using a configurable Program Counter (PC) substitution mechanism. Both the patching instructions and PC substitution data are stored in a designated NAND cell area and loaded at power-up along with the electrical fuse data. As the scheme is designed to handle only a small number instruction patches, the area overhead remains minimal.

Effects of Feeding a Combination of Probiotics Containing Lactobacillus plantarum and Bacillus Subtilis on Immune Response and Diarrhea Incidence in Post-weaning Piglets (이유자돈에 대한 Lactobacillus plantarum과 Bacillus subtilis 합제 투여에 따른 면역반응과 설사발생에 미치는 효과)

  • Park, Eun-Kee;Yoo, Eun-Ah;Cha, Chun-Nam;Tutkun, Engin;Kim, Suk;Lee, Hu-Jang
    • Journal of Veterinary Clinics
    • /
    • v.30 no.6
    • /
    • pp.459-463
    • /
    • 2013
  • A study investigated the effects of a mixture of Lactobacillus plantarum (L. plantarum) and Bacillus subtilis (B. subtilis) on diarrhea incidence, immune response, and fecal microflora counts in post-weaning piglets. One hundred 28-day-old piglets were randomly assigned to five treatment groups: negative control (NC), free of antibiotics; positive control (PC), 0.03% chlortetracycline; LB 1, a mixture of L. plantarum and B. subtilis (LB) 0.5 kg/ton feed; LB 2, LB 1.0 kg/ton feed; and LB 3, LB 2.0 kg/ton feed. Diarrhea scores for LB 2 and LB 3 from the 2nd week were significantly reduced compared to NC (P<0.05). In terms of the level of IgG and IFN-${\gamma}$, all treatment groups were significantly higher than NC (P<0.05), and the IgG level of LB 3 was significantly higher than that of PC (P<0.05). Furthermore, fecal lactic acid bacteria (LAB) counts for LB 2 and LB 3 were significantly higher than those of NC and PC (P<0.05). In addition, fecal Enterobacteriaceae (ENT) counts for PC, LB 2 and LB 3 were significantly lower than those of NC (P<0.05). Based on the results from this study, it was concluded that a combination of L. plantarum and B. subtilis strains could be used as potential alternatives to antibiotics to prevent diarrhea incidence in piglets.