Browse > Article
http://dx.doi.org/10.4334/JKCI.2010.22.4.441

Seismic Performance of Precast Beam-Column Joints with Thru-Connectors  

Park, Soon-Kyu (Dept. of Architecture, University of Ulsan)
Kim, Min-Hee (Dept. of Architecture, University of Ulsan)
Publication Information
Journal of the Korea Concrete Institute / v.22, no.4, 2010 , pp. 441-450 More about this Journal
Abstract
This is a preliminary study on the development of precast beam-column joints for dry construction methodology. Precast beam column joints with thru-connectors (BCJ_TC) using high strength bars or PS strands were developed and their seismic performance including strength degradation, stiffness degradation and energy dissipation capacity was experimentally evaluated. Test results showed that compressive failures at the end blocks of PC beam members occurred dominantly while PC columns including panel zones were free from any damage. However, the connections confined with CFRP at the end block showed much improved seismic performance than that of the unconfined connections. Connections with neoprene pad fillers between beam and column interfaces were better than the other connections in all the seismic performances except initial stiffness. To improve the seismic performances of BCJ_TC, compressive strength of the concrete at the end block need to be increased to compensate for the additional compressive stresses due to unbonded connectors and deformation of connectors should be controlled respectively.
Keywords
PC system; beam-column joint; thru-connectors; unbonded; post-tension;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Lin, C. M., “Seismic Behavior and Design of Reinforced Concrete Interior Beam Column Joints,” Department of Civil Engineering University of Canterbury Christchurch, New Zealand, 2000, pp. 298-306.
2 서수연, 이리형, 진세옥, 최윤철, “강한 기둥-약한 보로 설계된 철근 콘크리트 골조구조의 변형성능 평가에 관한 연구,” 한국구조물진단학회, 7권, 4호, 2003, pp. 225-233.
3 Collins, M. P. and Mitchell, D., Prestressed Concrete Structures, Prentice-Hall, New Jersey, 1991, pp. 175-18.
4 ACI T1.1R-01, “Commentary on Acceptance Criteria for Moment Frames Based on Structural Testing,” ACI Manual of Concrete Practice, ACI, 2002, pp. 1-7.
5 Cheok, G. S. and Lew, H. S., “Model Precast Concrete Beam to Column Connections Subjected Cyclic Loading,” PCI Journal, Vol. 38, No. 4, 1993, pp. 80-92.   DOI
6 Stone, W. C., Cheok, G. S., and Stanton, J. F., “Performance of Hybrid Moment-Resisting Precast Beam-Column Concrete Connections Subjected to Cyclic Loading,” ACI Structural Journal, Vol. 91, No. 2, 1995, pp. 229-249.
7 Priestley, M. J. N. and Tao, J. R., “Seismic Response of Precast Prestressed Concrete Frames with Partially Debonded Tendons,” PCI Journal, Vol. 38, No. 1, 1993, pp. 58-66.
8 Tani, M., “Ultimate Flexural Strength Evaluation for Prestressed Concrete Columns,” Fumio Watanabe Symposium, Kyoto, 2008, pp. 281-289.
9 여인석, “PCS 구조 시스템의 내진 성능 분석,” 콘크리트학회 논문집, 19권, 3호, 2007, pp. 313-322.   과학기술학회마을   DOI   ScienceOn
10 김무경, “PCS 구조 시스템 접합부의 초기 강성에 대한 연구,” 콘크리트학회 논문집, 20권, 3호, 2008, pp 271-282.   과학기술학회마을   DOI   ScienceOn
11 ACI, “Building Code Requirements for Structural Concrete (ACI318-08) and Commentary (Chapter 21),” ACI Manual of Concrete Practice (Part3), 2008, pp. 323-349.