• 제목/요약/키워드: Polyether

검색결과 189건 처리시간 0.028초

수전해용 공유가교 SPEEK/Cs-TSiA 막의 Ceria의 함량에 따른 제조 및 성능 연구 (Study of Synthesis and Performance of Covalently Cross-Linked SPEEK/Cs-TSiA Composite Membranes with Ceria Contents for Water Electrolysis)

  • 윤대진;오연선;서현;문상봉;정장훈
    • 한국수소및신에너지학회논문집
    • /
    • 제26권3호
    • /
    • pp.212-220
    • /
    • 2015
  • The engineering plastic of sulfonated polyether ether ketone (SPEEK) as a polymer matrix has been developed in this lab to replace Nafion, solid polymer electrolytes of perfluorosulfonic acid membrane which has several flaws such as high cost, and limited operational temperature above $80^{\circ}C$. The SPEEK was prepared in the sulfonation reaction of polyether ether ketone (PEEK). The organic-inorganic blended composite membranes were prepared by sol-gel casting method with loading the highly dispersed ceria and cesium-substituted tungstosilicic acid (Cs-TSiA) with cross-linking agent contents of 0.01 mL. In conclusion, CL-SPEEK/Cs-TSiA/ceria 1% membrane showed the optimum results such as 0.1882 S/cm of proton conductivity at $80^{\circ}C$, and 99.61 MPa of tensile strength which were better than Nafion 117 membrane.

Displacement of scan body during screw tightening: A comparative in vitro study

  • Kim, JungHan;Son, KeunBaDa;Lee, Kyu-Bok
    • The Journal of Advanced Prosthodontics
    • /
    • 제12권5호
    • /
    • pp.307-315
    • /
    • 2020
  • PURPOSE. The purpose of this study was to evaluate the occurrence of displacement while tightening the screw of scan bodies, which were compared according to the material type. MATERIALS AND METHODS. Three types of scan bodies whose base regions were made up of polyether ether ketone (PEEK) material [Straumann Group, Dentium Group, and Myfit (PEEK) Group] and another scan body whose base region was made up of titanium material [Myfit (Metal) Group] were used (15 per group). The reference model was fabricated by aligning the scan body library on the central axis of the implant, and moving this position by the resin model. The screws of the scan bodies were tightened to the implant fixture with torques of 5 Ncm, 10 Ncm, and a hand tightening torque. After the application of the torque, the scan bodies were scanned using a laboratory scanner. To evaluate the vertical, horizontal, and 3-dimensional (3D) displacements, a 3D inspection software program was used. To examine the difference among groups, one-way analysis of variance and Tukey's HSD post hoc test were used (α=.05). RESULTS. There were significant differences in 3D, vertical, and horizontal displacements among the different types of scan bodies (P<.001). There was a significantly lower displacement in the Straumann group than in the Myfit (PEEK) and Dentium groups (P<.05). CONCLUSION. The horizontal displacement in all groups was less than 10 ㎛. With the hand tightening torque, a high vertical displacement of over 100 ㎛ occurred in PEEK scan bodies (Myfit and Dentium). Therefore, it is recommended to apply a tightening torque of 5 Ncm instead of a hand tightening torque.

Lamb skin 코팅용 polyether polyol을 이용한 hard segment를 형성하는 polyurethane compound의 합성 및 물성에 관한 연구 (A study on properties and synthesis of polyurethane compound formed hard segments by polyether polyol for lamb skin coat)

  • 이주엽;남상성
    • 한국응용과학기술학회지
    • /
    • 제31권2호
    • /
    • pp.296-304
    • /
    • 2014
  • 본 연구에서는 hard segment를 형성하고 있는 폴리우레탄을 합성한 다음 피혁산업에서 마감 코팅시 많이 사용되고있는 폴리에틸렌왁스의 적하량을 점차 증가시켜 필름 및 Lam skin에 코팅에 적용하여 변화하는 물성을 측정하였다. 내용제성 측정 결과 높은 내용제성 물성을 지닌 폴리우레탄 수지에 폴리에틸렌왁스의 함량에 따른 물성적 변화는 크게 나타나지 않았다. 인장 강도 측정치에서는 폴리우레탄 단독 필름의 측정치가 $1.235kg_f/mm^2$로 가장 높은 수치를 나타내었으며, 폴리에틸렌왁스의 함량이 제일 높은 PUD-EW3가 가장 낮은 인장력 $1.022kg_f/mm^2$를 나타내었다. 또한 내마모도 측정에서는 PUD가 제일 높은 52.22 5mg.loss로 우수한 물성변화를 나타내었고, 연실율의 경우 역시 우레탄 단독 코팅인 PUD가 698%로 가장 높은 수치를 나타내었다.

폴리우레탄폼의 흡음율에 대한 첨가제의 영향 (The Effect of Additives on Sound Absorption Coefficient of Polyurethane Foam)

  • 박남국;김영철;박종래
    • 공업화학
    • /
    • 제8권2호
    • /
    • pp.197-203
    • /
    • 1997
  • 본 연구에서는 폴리우레탄폼 제조시 사용되는 첨가제가 폴리우레탄폼의 기계적 물성에 미치는 영향에 대하여 조사하였다. 실험에 사용된 수지는 KONIX FA-703 폴리에테르폴리올(80%)과, KONIX FA-733 폴리에테르폴리올(20%)에 촉매, 계면활성제, 가교제 등을 혼합하여 제조하였으며, 이 수지에 이소시아네이트(TDI-80, prepolymer M-200, pure MDI)를 당량비로 첨가하여 발포시킨 폼을 상온에서 72시간 경화시킨 후 물성측정에 사용하였다. 폴리우레탄폼의 기계적 물성은 밀도, 인장강도, 인열강도, 신장율, 흡음율 및 gel profile을 조사함으로써 측정하였고, 셀 크기에 대한 계면활성제의 영향은 주사전자현미경(SEM)을 사용하여 측정하였다. 흡음율은 셀의 크기와 직접적인 관련이 있었으며, 계면활성제(L-5309)의 사용량에 따른 인장강도, 인열강도 및 흡음율 등 기계적 물성은 1.0pphp 까지는 첨가량이 많아질수록 증가하는 경향을 보이다가 점차 감소하였다.

  • PDF

PEI/PEBAX 복합 중공사 막을 이용한 수분 제거에 관한 연구 (Study on the Removal of Water Vapor Using PEI/PEBAX Composite Hollow Fiber Membrane)

  • 박천동;형찬희;김기홍;최원길;박영성;이형근
    • 멤브레인
    • /
    • 제23권2호
    • /
    • pp.119-128
    • /
    • 2013
  • 본 연구에서는 복합 중공사 막을 이용하여 가스 중 수분(water vapor)의 제거에 관한 연구를 수행하였다. 막 소재로는 PEI (Polyetherimide)를 사용하였고 건/습식 상전이 법을 이용하여 중공사 형태로 제조한 후, 표면에 PEBAX (Polyether block amides) 3533또는 PEBAX1657를 코팅하여 복합 중공사막을 제조하였다. 제조된 중공사 막에 대한 SEM 관찰을 통하여 외부 표면에 치밀한 선택층과 망상구조의 하부로 이루어진 비대칭 구조임을 확인하였다. 막의 수분 투과특성을 확인하기 위하여 수분활성도(Water activity), 온도와 압력 변화에 따른 수분과 $N_2$의 투과도를 측정하였다. PEBAX3533을 코팅한 복합중공사 막의 수분 투과도는 운전 조건에 따라 385.6~727.3 GPU, 수분/$N_2$ 선택도는 61.7~118.5의 값을 나타내었다. PEBAX1657 코팅의 경우, 수분 투과도는 204.1~562.1 GPU, 수분/$N_2$ 선택도는 85.3~175.4의 값을 나타내었다. 막의 수분제거율은 PEBAX3533 코팅한 경우에 90%를 나타내었다.

이형유 종류에 따른 Cake 제품의 이탈성, 이형유의 과산화물가 및 산가의 변화 (Effect of the Pan Oil Type on the Releasing Power, Changes of Peroxide and Acid alue of the Oil)

  • 이정훈;조남지
    • 한국식품영양학회지
    • /
    • 제11권2호
    • /
    • pp.137-142
    • /
    • 1998
  • 요오드가 다른 4종류의 기본유(soybean oil, palmolein, coconut oil, corn oil)에 lecithin과 wax를 일정량 첨가하여 16종류의 시료 이형유를 만든 후 polyether sulphone로 피복한 철판에 케익을 구워 이탈율의 정도 그리고 이형유 제조 직후와 구운후의 이형유 시료들의 산가와 과산화물과 변화를 조사한 결과를 요약하면 다음과 같다. 1. 이탈에 가장 큰 영향을 주는 것은 첨가물보다 기본유 자체의 성질에 있는 것으로 나타났다. 요오드가가 낮을수록 즉 포화 지방산이 많을수록 이탈률이 좋았다. 가장 좋은 이탈률을 보인 것은 coconut oil에 wax 2%와 Lecithin 2%를 첨가하여 제조한 것으로 도포량에 관계없이 좋은 이탈률을 보였다. 2. 산가는 이형유 조제 직후에나 구운 후에도 큰 변화가 없었다. Soybean oil, palmolein, corn oil, coconut oil은 각각 구운 후의 산가가 0.045, 0.048, 0.085, 0.044를 나타냈다. 3. 철판유 제조 직후 과산화물가는 soybean oil, palmolein, corn oil, coconut oil이 각각 1.19, 0.81, 1.00 그리고 1.10이었으나 구운 후에는 7.9, 7.0, 10.9, 9.9로 고온에서 과산화물가가 급격하게 상승하였다.

  • PDF

수종 인상재의 침지 소독이 경석고 모형의 크기 안정성에 미치는 영향에 관한 연구 (A STUDY ON DIMENSIONAL STABILITY OF IMPRESSION MATERIALS FOLLOWING IMMERSION DISINFECTION)

  • 송기용;양재호;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.506-515
    • /
    • 1999
  • Dental practice can produce and spread some infectious diseases from patients to dentist, dental assistant, and dental labors. One possible method for preventing these cross-contamination is to immerse dental impression in chemical disinfectants. So for many investigators studied on the dimensional changes of dental impressions and on the surface qualities of stone casts made from impression following immersion in disinfectants. This study was proposed to evaluate some popular impression disinfectant combination from the point of dimensional stability. Impression was taken from dental arch-shaped metal model. Irreversible hydrocolloid and 3 elastomers(polyvinyl siloxane, polysulfide, polyether) were immersed in 3 disinfectants (2% glutaraldehyde, 1% povidone-iodine, 0.5% sodium hypochlorite) for 10 minutes and measured both cross-arch and anterior-posterior distance under stereo microscope to evaluate dimensional change. The results obtained were as follows: 1. Dimensional changes of irreversible hydrocolloid impression was statistically different in cross-arch and anterior-posterior distance when immersed in 2% glutaraldehyde solution and in anterior-posterior distance when immersed in 0.5% sodium hypochlorite solution from control group (p<0.05). 2. Dimensional changes of polyvinyl siloxane and polysulfide impression were not statistically different from control group (p>0.05). 3. Dimensional changes of polyether impression was statistically different in cross-arch distance when immersed in 0.5% sodium hypochlorite solution and in anterior-posterior distance when immersed in 1% povidone-iodine solution from control group (p<0.05). 4. In all cases, dimensional changes were less than 0.1% from the original dimension and concluded clinically acceptable.

  • PDF

Cs 치환에 따른 수전해용 공유가교 SPEEK/Cs(n)-MoPA/Ceria 1%(n = 1~3) 복합막의 특성 연구 (Research of Characterization of Covalently Cross-linked SPEEK/Cs-Substituted MoPA/Ceria 1wt% Composite Membrane for Water Electrolysis)

  • 박대영;황성하;오승희;윤대진;강안수;문상봉;정장훈
    • 한국수소및신에너지학회논문집
    • /
    • 제25권1호
    • /
    • pp.1-10
    • /
    • 2014
  • Ceria ($CeO_2$) was used to scavenge free radicals which attack the membrane in the polymer electrolyte membrane water electrolysis (PEMWE) circumstance and to increase the duration of the membrane. In order to improve the electrochemical, mechanical and electrocatalytic characteristics, engineering plastic of the sulfonated polyether ether ketone (SPEEK) as polymer matrix was prepared in the sulfonation reaction of polyether ether ketone (PEEK) and the organic-inorganic blended composite membranes were prepared by sol-gel casting method with loading the highly dispersed ceria and cesium-substituted phophomolybdic acid(Cs-MoPA) with cross-linking agent contents of 0.01mL. In conclusion, CL-SPEEK/$Cs_{(2.5)}$-MoPA/ceria(1%) membrane showed the optimum results such as 0.1095S/cm of proton conductivity at $80^{\circ}C$, 2.906meq./g-dry-membrane of ion exchange capacity and mechanical characteristics, and 49.73MPa of tensile strength which were better than Nafion 117 membrane.

RF Characteristics of Open Stubs on PES Substrate for Application to Capacitive Matching Components on Flexible MMIC

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong-Seung;Jang, Nak-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권3호
    • /
    • pp.142-145
    • /
    • 2015
  • In this work, open stubs were fabricated on a polyether sulfone (PES) substrate, and their basic radio frequency (RF) characteristics were investigated for application to RF matching components of a flexible monolithic microwave integrated circuit (MMIC). According to the results, an open stub employing coplanar waveguide (OSCPW) on PES exhibited much lower loss than that on silicon substrate. The OSCPW with a length of $500{\mu}m$ on PES showed capacitance values of 0.031 ~ 0.044 pF from 0.5 to 50 GHz. For application to a relatively high-value capacitive matching, an open stub employing a fishbone-type transmission line (OSFTTL) was fabricated on PES, and its characteristics were investigated. The OSFTTL showed much higher capacitance values than the OSCPW due to the high effective permittivity value. Specifically, the OSFTTL on PES showed capacitance values of 0.066 ~ 0.24 pF from 0.5 to 50 GHz, which are higher than those for the open stub on silicon substrate. The above results indicate that the OSCPW and OSFTTL on PES can be effectively used for application to low/high-value capacitive matching components on microwave and millimeter wave flexible MMIC. To the best of the authors' knowledge, this work is the first report of the investigation of RF capacitive matching components on PES substrate.

전기분사를 이용한 양성담관 협착 치료용 약물방출 스텐트 개발 (Development of Drug Eluting Stent for the Treatment of Benign Biliary Stricture by Electro-spray Method)

  • 신일균;김동곤;김한기;김상호;전동민;서태석;장홍석
    • 폴리머
    • /
    • 제36권2호
    • /
    • pp.163-168
    • /
    • 2012
  • 최근에 내시경 관련기술의 진보에 따라서 시술 편리성, 회복시간 단축, 환자 고통 경감 등의 장점으로 인해 스텐트 삽입술이 빠르게 진보하였다. 본 연구에서 양성담관 협착 치료를 목적으로 파클리탁셀을 이용한 약물방출 스텐트를 전기분사 방법에 의해 제조하였으며, 이 때 사용된 고분자는 polyether-based polyurethane(상표명 : PELLETHANE 2363-80AE$^{(R)}$)과 첨가제로서 Pluronic F127, 약물로서 파클리탁셀을 사용하여 금속스텐트 표면에 코팅하였다. 그 결과로서, 약물이 코팅된 고분자 필름의 물리적 특성은 SEM, FTIR, 접촉각 측정기, XRD에 의해 확인하였으며, 약물방출속도는 약물함량이 높을수록 감소하였음을 알 수 있었다.