• Title/Summary/Keyword: Platform Screen Door (PSD)

Search Result 64, Processing Time 0.022 seconds

Unsteady Wind Pressure Analysis on PSD Considering Subway Station Configurations (지하철 역사 형상을 고려한 PSD 비정상 풍압해석)

  • Kim, Yu-Sung;Kim, Yo-Han;Shin, Kwang-Bok;Lee, Eun-Kyu;Kim, Dong-Hyun
    • Journal of the Korean Society for Railway
    • /
    • v.11 no.1
    • /
    • pp.13-18
    • /
    • 2008
  • In this study, unsteady wind pressure analyses on platform screen door (PSD) have been conducted considering the flow intereference effects between the moving train and the configuration of subway station. The major role of PSD prevents passenger accidents, wind pressure, polluted dust and noise when the train is entering the station platform. Computational fluid dynamic method with moving gird algorithm has been adopted to accurately predict unsteady pressure levels exerted on the PSD. Closed and open type station configuration are considered. Also, wind pressure levels for passing and stopping drive motion of the entering train are presented and practically compared each other.

Effect of Platform Screen Door on fire in the subway station (스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구)

  • Jang, Yong-Jun;Jung, Woo-Sung;Park, Won-Hee;Kim, Hag-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1337-1345
    • /
    • 2007
  • The present study is a basic investigation for systematically proceeding disaster prevention studying the effect of platform screen door in case of fire at the subway station. In the paper, the characteristics of screen door were surveyed and described. The fully closed platform screen door and the island type of subway station were employed for simulation-study. Numerical simulations of fire driven flow at the subway station with platform screen door were performed with commercial fire CFD code. For analyzing of the effect of platform screen door, the fire simulations with and without the platform screen door were compared. For the fire location, the one is located on the platform and the other case on the railway. The Ultrafast model was taken as fire growth scenario. The maximum heat release rate was 10MW. The propagated time of the heat and smoke to stairs was within 4 minute when the fire is located on the platform. However the heat and smoke propagation was block off by screen door when the fire is located on the railway.

  • PDF

The Technical Suggestion for Implementing Animated PSD Ads : Focused on Seoul Metro Line2 (동적 PSD광고 구현을 위한 기술적 제안 : 수도권 지하철 2호선을 중심으로)

  • Kim, Kyoung-Joo;Kim, Suk-Rae
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.381-391
    • /
    • 2018
  • The purpose of this research is to propose a new method of PSD(Platform Screen Door) ads using animated image for efficiency, based on the theoretical background that moving objects have a stronger visual attractiveness effect than static objects. For this, we analyze the relationship between the screen door and the train, then derive the positional and visual elements which help to create efficient animated images. Based on this analysis, we made an example and applied into 3D program to confirm the implementation process of the animated PSD ads. As the result, the research shows that it is possible to produce a new type of PSD ads that can show dynamic visual effects and can give diversity to the PSD advertising media through the combination of the images using time difference.

Feasibility analysis of RPSD(Rope type Platform Safe Door) on the simulation (시뮬레이션을 통한 로프타입 상하개폐식 승강장 안전문 적용성 검토)

  • Kang, Hee-Chan;Kim, Hyun;Chung, Younshik
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.2
    • /
    • pp.22-29
    • /
    • 2013
  • The platform safety door is difficult to install in platform because the doors of railway vehicles and existing Passenger Safety doors should be alined. To be able to solve this problem, we propose the use of Rope Type Platform Safe Door (RPSD) which is a vertically retractable platform that is designed to close from top to bottom. This platform has installed safety gate pillars at intervals of 20-40 m which accommodates different types of train regardless of train length, gate opening and location. In this paper, we reviewed the application of existing PSD and RPSD in various train stops in Seoul Gyeongbu Line platform. The results of the review showed that the existing PSD may cause problem in construction, safety and cost efficiency. The use of RPSD however shows that minimal problems will be encountered.

Development of the Manual Opening and Closing Algorithm for Vertical Rope Type Platform Safe Door and Its Evaluation (상하개폐형 RPSD의 수동개폐 알고리즘 개발 및 평가)

  • Choi, Gapyeol;Kim, Hyun
    • Journal of Korean Society of Transportation
    • /
    • v.32 no.3
    • /
    • pp.248-255
    • /
    • 2014
  • Though the Platform Screen Door System (PSD) has received a positive evaluation and is installed in all the Urban Railroad platforms, PSD is not installed in the Intercity Railroad platforms. The limitation of PSD in the Intercity Railroad platforms is due to the fact that first, various types of trains such as KTX, Saemaeul, Mugunghwa, and Nuriro stop at the platforms and their locations of the doors are different and secondly, they are not operated under ATO (automatic train operation). RPSD system currently under research and development, on the other hand, is based on the improved door that slides up and down and can be installed in any Intercity Railroad platform regardless of the length of the train, the location of doors, and the number of doors. This study considers the mechanism of RPSD, develops a manual open/close algorithm, and evaluates the function of RPSD. The results show that the manual open/close algorithm achieves a significant improvement in efficiency when provided with power supply.

WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF ISLAND PLATFORMS IN A SUBWAY STATION CAUSED BY A PASSING TRAIN (섬식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압 해석)

  • Lee, Myung-Sung;Won, Chan-Shik;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • v.12 no.3
    • /
    • pp.1-7
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in island platform caused by a passing train are investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique adopted for the train movement. To achieve more accurate results, detailed shape of train is included in a computational domain and the entrance and exit tunnel of platform are also modeled. Numerical analyses are conducted on three operational conditions of different velocity variation.

Study for Interface Between EMU and PSD in Metro (도시철도의 전동차와 PSD 인터페이스 고찰)

  • Seon, Jong-Min;Jo, Eun-Je;Yang, Dong-Seok;Park, Hee-Chul
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1397-1404
    • /
    • 2011
  • Metro serves more than a basic function of transporting passengers between short distances but became a crucial part of civic culture due to the fact that citizens demand various facilities for better life style. Therefore, domestic metro cuts off train noise and air dust, provides pleasant platform surroundings by offering effective HVAC, and establishes PSD (Platform Screen Door) system to prevent falls into train tracks. To control and interlock EMU Door and PSD to avoid passenger complaint and revenue service obstructions, stability and reliability of on-board & wayside equipment are required foremost and each line needs to build optimum interface between on-board & wayside equipment. To control PSD, we would like to introduce examples of Busan Metro(BTC : Busan Transportation Corporation) which already utilizes interface between on-board & wayside equipment in various ways and consider optimum interface between on-board & wayside equipment in future PSD system.

  • PDF

WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STAT10N CAUSED BY PASSING TRAINS (상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석)

  • Lee, Myung-Sung;Lee, Sang-Hyuk;Hur, Nahm-Keon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2007.04a
    • /
    • pp.64-67
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is obtained with actual operational condition of subway train and the moving mesh technique is adopted considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel of platform are included in a computational domain and detailed shape of train is also modeled Numerical analyses were conducted on five operational condition which are different velocity variation of subway train, existence of stationary train and passing each other trains. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation was found to be satisfactory to various foreign standards.

  • PDF

PSD Door Response Time Improving Method in Train Manual Operation Mode (수동운전방식에서의 PSD 출입문 신호반응 시간 개선 방안 연구)

  • Lee, Moo-Ho;Kim, Chan-Cum;Lee, Suk-Jong;Lee, Soo-Young
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.559-571
    • /
    • 2008
  • Platform Screen Door(PSD) has been installed and operated at seoul subway line $1\sim4$ in the manual train operation mode(ATS/ATC) by SeoulMetro since 2005. SeoulMetro uses the wireless (RF) communication system and the train door detection system for the link between the train and PSD doors opening/closing motion in the manual train operation mode. For the convenience and safety of passengers, the train doors and the PSD doors opening/closing shall be synchronized as much as possible. In ATO(Automatic Train Operation) mode which provides the interface between train control system and PSD system, ATO signaling system makes the train doors and PSD doors open/close command signals systematically, so PSD doors can be opened/closed almost simultaneously with the train doors. But, in the manual train control(ATS/ATC) mode, PSD system needs to detect the train doors open/close operation and make PSD open/close command signals to actuate PSD doors. These PSD open/close commanding process cause time delay of PSD doors opening/closing motion in response to the train doors opening/closing motion. Sometimes the response delay time can be over 1 second, which is not proper to operate PSD, and need to be reduced This paper presents the reduction method of the PSD response delay time to improve the convenience and safety of passengers.

  • PDF

WIND PRESSURE TRANSIENTS ON PLATFORM SCREEN DOOR OF SIDE PLATFORMS IN A SUBWAY STATION CAUSED BY PASSING TRAINS (상대식 승강장에서 열차 운행에 의한 지하철 승강장 스크린 도어 풍압해석)

  • Lee, Myung-Sung;Lee, Sang-Hyuk;Hur, Nahm-Keon
    • Journal of computational fluids engineering
    • /
    • v.12 no.4
    • /
    • pp.1-6
    • /
    • 2007
  • In the present study, the wind pressure transients on platform screen door in side platforms caused by passing trains have been investigated numerically. The transient compressible 3-D full Navier-Stokes solution is used with actual operational condition of subway train by adopting the moving mesh technique considering the train movement. To achieve more accurate analysis, the entrance and exit tunnel connecting the stations are included in a computational domain with modeling the detailed shape of the train. Numerical analyses are conducted on five operational conditions which include the variation of the train speed, case with or without the train stopped in the other track, and case for two trains passing each other inside the station. The results show that pressure load on platform screen door is maximized when the two trains are passing each other. It is also seen from the computational results that the maximum pressure variation for the cases considered in the present study is found to be satisfactory to various foreign standards.