• 제목/요약/키워드: Piezoelectric Film Method

검색결과 113건 처리시간 0.023초

압전층의 2단 증착법을 이용한 체적 음향파 박막형 공진기의 제작과 성능향상에 관한 연구 (A Study of the Fabrication and Enhancement of Film Bulk Acoustic Wave Resonator using Two-Step Deposition Method of Piezoelectric Layer)

  • 박성현;추순남;이능헌
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권7호
    • /
    • pp.308-314
    • /
    • 2005
  • The 2 GHz film bulk acoustic wave resonator(FBAR), one of the most necessary device of the next generation mobile communication system, consisted of solidly mounted resonator(SMR) structure using Brags reflector, was researched in this paper The FBAR applied SiO$_{2}$ and W had large difference of the acoustic impedance to reflector Al to electrode and ZnO to piezoelectric layer. Specially, the FBAR applied the two-step deposition method to improve the c-axis orientation and increase reproducibility of the fabrication device had good performance. The electrical properties of plasma such as impedance, resistance, reactance, $V_{pp},\;I{pp}$, VSWR and phase difference of voltage and current, was analyzed and measured by RF sensor with the variable experiment process factors such as gas ratio, RF power and base vacuum level about concerning the thickness, c-axis orientation, adhesion and roughness. The FBAR device about the optimum condition resulted reflection loss(S$_{11}$) of -17 dB, resonance frequency of 1.93 GHz, electric-mechanical coefficient(k$_{eff}$) of 2.38 $\%$ and Qualify factor of 580. It was seen better qualify than the common dielectric filter at present and expected on business to the filter device of 2 GHz bandwidth with the MMIC technology.

생체 조직의 국소 강도 측정을 위한 마이크로 콘 팁을 가진 압전 캔틸레버 제작 (Fabrication of Piezoelectric Cantilever with Microcone Tip for Sensing Local Stiffness of Biological Tissue)

  • 노희창;양다솜;류원형
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.743-748
    • /
    • 2017
  • 체외 및 체내 삽입형 이미징 기술 등에 의해서는 판별이 어려운 질환의 조기 진단을 위해 인체 내 삽입이 가능하며 체내 국소부위의 정밀 측정이 가능한 새로운 진단기술이 필요하다. 동맥경화로 발전할 수 있는 죽상경화반의 경우 이미징 기술로는 판별이 어려우나 건강한 조직 대비 미세한 기계적 물성치의 차이를 가질 것으로 예상되어 정밀한 국소 조직의 기계적 강도 측정을 통한 조기 진단이 가능할 것으로 기대된다. 본 연구에서는 궁극적으로 체내 삽입이 가능하며 국소 조직의 강도 측정이 가능한 압전 재료 기반 캔틸레버 센서를 제작하고자 하였다. 압전 기능을 갖는 캔틸레버 제작을 위해 $BaTiO_3$ 나노입자 기반의 압전 고분자 복합재 최적화 연구 및 열 인장 공정으로 캔틸레버 끝 단에 마이크로 콘 구조의 팁을 제작하였다. 이 압전 캔틸레버 센서를 이용하여 기계적 물성치가 다른 생체 조직의 강도 측정을 통해 센서로서의 기능을 확인하였다.

대향타겟스퍼터링법에 의한 FBAR용 AZO(ZnO:Al) 전극의 제작 (Preparation AZO(ZnO:Al) thin film for FBAR by FTS method)

  • 금민종;신성권;가출현;추순남;김경환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 하계학술대회 논문집 Vol.4 No.1
    • /
    • pp.172-175
    • /
    • 2003
  • ZnO:Al thin film for application to FBAR's bottom electrode using ZnO piezoelectric thin film were prepared by FTS, in order to improve the crystallographic properties of ZnO thin films because the ZnO:Al thin film and ZnO thin films structure is equal each other. So we prepared the ZnO:Al thin film with oxygen gas flow rate. Thickness and c-axis preferred orientation and electric properties of ZnO:Al bottom electrode were evaluated by $\alpha$-step, XRD and 4-point probe..

  • PDF

대향타겟스퍼터링법에 의한 FBAR용 AZO(ZnO:Al) 박막의 제작 (Preparation AZO(ZnO:Al) Thin Film for FBAR. by FTS Method)

  • 금민종;김경환
    • 한국전기전자재료학회논문지
    • /
    • 제17권4호
    • /
    • pp.422-425
    • /
    • 2004
  • In this study, the AZO thin films were prepared as a function of oxygen gas flow ratio at room temperature by FTS(Facing Targets Sputtering) apparatus using Zn:Al(metal)-Zn:Al(metal) or Zn(metal)-ZnO:Al(ceramic). The film thickness, crystalline and electric properties of AZO thin film was evaluated by $\alpha$-step, XRD and 4-point probe. In the results, the resistivity of AZO thin film was shown the lowest value about 8${\times}$10$^{-2}$ $\Omega$-cm(Zn:Al-Zn:Al), 3${\times}$10$^{-1}$ $\Omega$-cm(Zn-ZnO:Al) at the oxygen gas flow ratio 0.3. And the AZO thin film has good crystalline at oxygen gas flow ration 0.4, using Zn:Al-Zn:Al targets.

Development of a Tactile Sensor Array with Flexible Structure Using Piezoelectric Film

  • Yu, Kee-Ho;Kwon, Tae-Gyu;Yun, Myung-Jong;Lee, Seong-Cheol
    • Journal of Mechanical Science and Technology
    • /
    • 제16권10호
    • /
    • pp.1222-1228
    • /
    • 2002
  • This research is the development of a flexible tactile sensor array for service robots using PVDF (polyvinylidene fluoride) film for the detection of a contact state in real time. The prototype of the tactile sensor which has 8${\times}$8 array using PVDF film was fabricated. In the fabrication procedure, the electrode patterns and the common electrode of the thin conductive tape were attached to both sides of the 281$\mu\textrm{m}$ thickness PVDF film using conductive adhesive. The sensor was covered with polyester film for insulation and attached to the rubber base for a stable structure. The proposed fabrication method is simple and easy to make the sensor. The sensor has the advantages in the implementing for practical applications because its structure is flexible and the shape of the each tactile element can be designed arbitrarily. The signals of a contact force to the tactile sensor were sensed and processed in the DSP system in which the signals are digitized and filtered. Finally, the signals were integrated for taking the force profile. The processed signals of the output of the sensor were visualized in a personal computer, and the shape and force distribution of the contact object were obtained. The reasonable performance for the detection of the contact state was verified through the sensing examples.

Sol-Gel 법에 의한 압전 PZT 후막의 제조 (Fabrication of Piezoelectric PZT Thick Film by Sol-gel Process)

  • 박종환;방국수;박찬
    • 한국해양공학회지
    • /
    • 제29권1호
    • /
    • pp.94-99
    • /
    • 2015
  • Lead zirconate titanate (PZT) thick films with thicknesses of ㎛ were fabricated on silicon substrates using an aerosol deposition method. A PZT powder solution was prepared using a sol-gel process. The average diameters (d50) obtained were 1.67, 1.98, and 2.40μm when the pyrolysis temperatures were 300℃, 350℃, and 450℃ respectively. The as-deposited film had a uniform microstructure without any cracks or pores. The as-deposited films on silicon were annealed at a temperature of 700℃. The 20-㎛-thick PZT film showed good adherence between the PZT film and substrate, with no tearing observed in the conventional solid phase process. This was probably because the presence of pores produced from organic residue during annealing relieved the residual stresses in the deposited film.

공진주파수 스펙트럼법을 이용한 Composite Resonator 구조에서 압전박막의 특성 평가에 대한 연구 (A Study on the Evaluation of Piezoelectric Thin Film Characteristics in Composite Resonator Structure Using Resonance Spectrum Method)

  • 최준영;장동훈;강성준;윤영섭
    • 대한전자공학회논문지SD
    • /
    • 제42권1호
    • /
    • pp.9-17
    • /
    • 2005
  • 공진주파수 스펙트럼법을 이용하여 ZnO 와 AIN 압전박막의 임피던스 특성 및 전기기계결합계수 특성에 대해 조사하였다. 압전박막의 두께가 얇을수록 전체적인 임피던스 응답 피크의 크기가 감소하였으며, 기판의 두께가 얇을수록 응답 피크의 모드 수가 감소하는 것이 관찰되었다. 입력 Kt² 값으로부터 평가된 Kt² 값을 통해 압전박막의 두께보다 기판의 두께 변화에 대한 영향이 더 큼을 알 수 있었고, 기판의 acoustic 임피던스에 의해서도 Kt² 값이 감소함을 알 수 있었다. 전극 효과가 첨가되면 임피던스 응답 피크의 크기가 감소하였으며, 전극의 acoustic 임피던스가 커짐에 따라 응답피크는 더 작아졌다. 공진주파수 스펙트럼법에서 전극은 질량부하로 고려되기 때문에 전극 효과가 첨가된 경우 Keff² 값은 증가하며, 전극의 acoustic 임피던스가 크면 그 효과는 더 커졌다. 공진주파수 스펙트럼법을 이용한 시뮬레이션을 통해 기판, 압전체, 전극으로 이루어진 composite 공진기의 특성 분석과 설계까지도 가능함을 알 수 있었다.

LTCC 기판을 이용한 PZT 압력 센서의 제작 및 특성 연구

  • 허원영;황현석;이태용;이경천;송준태
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 춘계학술대회 논문집
    • /
    • pp.13-13
    • /
    • 2010
  • Piezoelectric sensors are extensively used to measure force because of their high sensitivity and low cost. however, the development of device with reduced size but with improved sensitivity is highly important. Low-temperature co-fired ceramic (LTCC) is one of promising materials for this application than a silicon substrate because it has very good electrical and mechanical properties as well as possibility of making various three dimensional (3D) structures. In this work, piezoelectric pressure sensors based on hybrid LTCC technology were presented. The LTCC diaphragms with thickness of $400\;{\mu}m$ were fabricated by laminating 12 green tapes which consist of alumina and glass particle in an organic binder. The piezoelectric sensing layer consists of PZT thin film deposited by RF magnetron sputtering method on between top and bottom Au electrodes. The PZT films deposited on LTCC diaphragms were successfully grown and were analyzed by using X-ray diffraction method (XRD) and field emission scanning electron microscope (FESEM).

  • PDF

Sol-Gel 법으로 제조된 후막 PZT의 두께, 전극형상 및 분극 공정에 따른 $e_{31,f}$ 특성 (Transverse Piezoelectric Coefficient ($e_{31,f}$) of Thick PZT films Fabricated by Sol-Gel Method with Thicknesses, Electrode Shapes and Poling Process)

  • 박준식;양성준;박광범;윤대원;박효덕;김승현;강성군;최태훈;이낙규;나경환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.1326-1331
    • /
    • 2003
  • Thick PZT films are required for the cases of micro actuators and sensors with high driving force, high breakdown voltage and high sensitivity, and so on. In this work, thick PZT films were fabricated by Sol-Gel multi-coating method. Total 8 types of samples using thick PZT films with thicknesses, about $1{\mu}m$ and $2{\mu}m$, and Pt top electrodes shapes for measuring transverse piezoelectric coefficient ($e_{31,f}$) were fabricated using MEMS processes. They were characterized by fabricated e31,f measurement system before and after poling. $e_{31,f}$ values of samples after poling were higher than before poling. Those of $2{\mu}m$ thick PZT films were also higher than $1{\mu}m$ thick PZT films. And those with long electrodes as top electrodes were also higher than shorter.

  • PDF

진공증착법을 이용한 압전 유기 박막의 제조와 센서 특성에 관한 연구 (A Study on the Fabrication of Piezoelectric Organic Thin Films by using Physical Vapor Deposition Method and Sensor Characteristics)

  • 박수홍;임응춘;박종찬;이덕출
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.35-39
    • /
    • 2001
  • The purpose of this paper is improvement the piezoelectric of Polyvinylidene fluoride(PVDF) organic thin films is fabricated by vapor deposition method. The piezoelectric of PVDF organic thin films attributed to dipole orientation in crystalline region. Also, the piezoelectric characteristic reduced that dipole moments orientation in crystalline region interfered with impurity carriers. Therefore, PVDF organic thin films fabricated with high substrate temperature condition for crystallinity improvement. The crystallinity of PVDF organic thin films fabricated by this condition increase from 47 to 67.8%. The ion density of PVDF organic thin films fabricated by substrate temperature variation from $30^{\circ}C$ to $105^{\circ}C$ decreased from $1.62{\times}10^{16}cm^3$ to $6.75{\times}10^{11}cm^3$ when temperature and frequency were $100^{\circ}C$, 10Hz, respectively. The $d_{33}$ and piezo-voltage coefficient of PVDF organic thin films increased from 20pPC/N to 33pC/N and $162.9{\times}10^{-3}V{\cdot}m/N$ to $283.2{\times}10^{-3}V{\cdot}m/N$, respectively. For the sake of the applications of piezoelectric sensor, we analyzed the output voltage characteristic as a function of the distance between an oscillator of 28kHz and PVDF organic thin film transducer. From this, we found that the output voltage is inversely proportional to the distance. At this time, the period was about $35.798{\mu}s$ and equal the oscillator frequency.

  • PDF