• 제목/요약/키워드: Pick-up System

Search Result 216, Processing Time 0.027 seconds

Implementation of Automatic 4 Points OPU Skew Adjustment Device with Height Compensation (높이 보정이 가능한 자동4점 Optical PICK-UP Skew 조정장치 구현)

  • Oh, Dong-Kyu
    • Proceedings of the IEEK Conference
    • /
    • 2008.06a
    • /
    • pp.1095-1096
    • /
    • 2008
  • By adding height compensation to the usual 3 points skew adjustment device, an improved functional skew adjustment device is implemented in this paper. The proposed skew adjustment device is for traverse which will be adapted to BD and HD player system requiring more accuracy. and It can adjust not only R/T skew but also height. The system is composed of personal computer, control box, kinematic mechanism device and bar-code reader device. Application programs are implemented by visual basic.

  • PDF

STUDY ON THE INFLUENCE OF POLYOL ON MICROEMULSION GEL SYSTEM (Microemulsion gel system에 있어서 Polyol의 효과에 관한 연구)

  • Youn, J.;Jin, P.K.
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.18 no.1
    • /
    • pp.132-149
    • /
    • 1992
  • This study relates to a microemulsion gel which is applied in various cosmetic preparations because of good appearance, superior stability and a thin, uniform, non-greasy fi Am on the skin. Main object of this study is to elucidate the influence of polyol(clarifying agent and/or coupling agent in microemulsion) on microemulsion and to establish the optimum conditions for microemulsion gel formation in the view of superior consistency, stability, clarity and pick-up from a container. The constituents of the system are composed of water, polar ester oi1, nonionic surfactant and polyol. Using the three-component phase diagram and the tetrahedral-phase diagram, we have investigated the changes of transparence regions, consistency and resonance effect by an impact in microemulsion gel varying in polyol ratio. The results of this study showed that the variation in the content of water and couple ins agent has major influence on the microemulsion gel and the optimum formation region of microemulsion gel is the widest when the ratio of glycerine(coupling agent) to water is 63-75% It is believed that optimum use of polyol seems to be helpful to obtain the microemulsion gel containing maximum amount of oil phase with minimum amount of surfactant which is recently one of the major problems of cosmetic chemists.

  • PDF

A Study of Safety System for High Platform (전철 고상홈 승강장안전시스템 개발시험)

  • 김명룡;권성태;박우현;홍용기
    • Proceedings of the KSR Conference
    • /
    • 2001.10a
    • /
    • pp.416-421
    • /
    • 2001
  • The subway station platform is designed in high platform for quick getting in/out which is against ordinary train platform. Out of 370 Metropolitan subway station platforms, subway stations which have cured platform are about 38%. In these cases, as the distance between subway and platform would become longer, handicapped people's wheelchairs, baby carriers and old and feeble people can feel uncomfortable when they are getting in and out Also, passengers often fall into track because of the height difference between high platform and track. And if passengers go down on track to pick up something fallen, they sometime fail to climb up and happen to hit against subway. To solve out these kind of inconveniences and prevent accidents, we have developed subway station high platform safety system and finished tests. This safety system is consisted of safety block, screened door and safety wall. This study explained the composition and function of this system and presented the test result to identify its performance.

  • PDF

The effect of phase modulation on the central peak intensity in an optical system (광학계의 위상 변조 조건에 따른 중심 강도 변화)

  • 이영철;정창섭;박성종;이윤우
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.2
    • /
    • pp.67-72
    • /
    • 2000
  • A lot of varIOUS studies are taking advantage of annular masks or various pupil filters to design optical systems such as a digital versatile disc (DVD) pick up head and precise scanning microscopy that have the superresolution beyond the diffraction limit. We considered both annular mask and pupil filter for the superresolution system. Since image quality is a function of annular width, position and modulation amount, we computel'lzed the optimized condition for the phase modulation and mvestigated the variation of lhe center peak: intensity for the phase modulated system From tills result, we were able to detenrune the best conditions for the annular apodizer, wluch give the maximum value of the center peak intensity_ We made especially sure that the phase modulated system have an excellent compensation for spherical aberration as it lllcreases. eases.

  • PDF

Analysis of the taxi telematics history data based on a state diagram (상태도에 기반한 택시 텔레매틱스 히스토리 데이터 분석)

  • Lee, Jung-Hoon;Kwon, Sang-Cheol
    • Journal of Korea Spatial Information System Society
    • /
    • v.10 no.1
    • /
    • pp.41-49
    • /
    • 2008
  • This paper presents a data analysis method for the taxi telematics system which generates a greate deal of location history data. By the record consist of the basic GPS receiver-generated fields, device-added fields such as taxi operation status, and framework-attached fields such as matched link Identifier and position ratio in a link, each taxi can be represented by a state diagram. The transition and the state definition enable us to efficiently extract such information as pick-up time, pick-up distance, dispatch time, and dispatch distance. The analysis result can help to verify the efficiency of a specific taxi dispatch algorithm, while the analysis framework can invite a new challenging service including future traffic estimation, trajectory clustering, and so on.

  • PDF

LG전자의 HiMEDIA 전략 및 제품

  • 김창호
    • Proceedings of the Korea Database Society Conference
    • /
    • 1995.12a
    • /
    • pp.68-79
    • /
    • 1995
  • HiMEDIA 전략 LG의 강점인 H/W 사업분야의 세계일류화를 지향하고, 향후 유망분야인 S/W와 Service 신 사업 참여에 LG의 역량을 집중토록함. $\square$ Hardware 신 사업: ⇒LG의 강점인 Device분야의 신제품의 지속적 개발(DVD, DVCR, HDTV등) ⇒한국 및 해외 Alliance 강화를 통한 VOD 사업 역량 배가 ⇒SI(System Integration)사업에 대한 타당성 검토 ⇒주요 Component의 핵심기술 개발(TFT-LCD, Optical Pick-up등)(중략)

  • PDF

Adaptive Maintenance Using Machine Condition Diagnosis Technique (설비진단기술를 활용한 적응보전)

  • 송원섭;강인선
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.17 no.30
    • /
    • pp.73-79
    • /
    • 1994
  • This paper propose Adaptive Maintenance as a new type of maintenance for machine failures which are unpredictable. A purpose of adpative maintenance is to decrease inconsistency. In order to pick up some of problems the traditional maintenance policy, We discussed Time Based Maintenance(TBM) and Condition Based Maintenance(CBM) with Bath-Tub Curve. By using Machine Condition Diagnosis Technique (CDT), Monitored condition maintenance deals with the dynamic decision making for diagnosis procedures at maintenance and caution level. Adaptive Maintenance is a powerful tool for Total Production Maintenance(TPM).

  • PDF

Detection of tension force reduction in a post-tensioning tendon using pulsed-eddy-current measurement

  • Kim, Ji-Min;Lee, Jun;Sohn, Hoon
    • Structural Engineering and Mechanics
    • /
    • v.65 no.2
    • /
    • pp.129-139
    • /
    • 2018
  • Post-tensioning (PT) tendons are commonly used for the assembly of modularized concrete members, and tension is applied to the tendons during construction to facilitate the integrated behavior of the members. However, the tension in a PT tendon decreases over time due to steel corrosion and concrete creep, and consequently, the stress on the anchor head that secures the PT tendon also diminishes. This study proposes an automatic detection system to identify tension reduction in a PT tendon using pulsed-eddy-current (PEC) measurement. An eddy-current sensor is installed on the surface of the steel anchor head. The sensor creates a pulsed excitation to the driving coil and measures the resulting PEC response using the pick-up coil. The basic premise is that the tension reduction of a PT tendon results in stress reduction on the anchor head surface and a change in the PEC intensity measured by the pick-up coil. Thus, PEC measurement is used to detect the reduction of the anchor head stress and consequently the reduction of the PT tendon force below a certain threshold value. The advantages of the proposed PEC-based tension-reduction-detection (PTRD) system are (1) a low-cost (< $ 30), low-power (< 2 Watts) sensor, (2) a short inspection time (< 10 seconds), (3) high reliability and (4) the potential for embedded sensing. A 3.3 m long full-scale monostrand PT tendon was used to evaluate the performance of the proposed PTRD system. The PT tendon was tensioned to 180 kN using a custom universal tensile machine, and the tension was decreased to 0 kN at 20 kN intervals. At each tension, the PEC responses were measured, and tension reduction was successfully detected.

Development of image processing based MLCC automatic inspection system (영상 처리 기반 MLCC 자동 검사 시스템 개발)

  • Seo, Ji Yoon;Park, Jun-mo;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.381-382
    • /
    • 2015
  • Small devices such as MLCC, sample inspection on the processing is not easy. If you can proceed with the sample inspection, the production process will be able to maximize the MLCC production efficiency. In this study, to minimize the interference of operator, and to maximize the operating efficiency of the equipment. Use image processing techniques for its extracts the position and angle of the MLCC. Implements an automatic inspection system with the high productivity.It is possible to inspect the final six MLCC devices. And once we Pick-Up to 200 Chip to check the accuracy of 98.4%. Based on the results of various studies are in progress to be expected to be applicable to the automatic inspection equipment side development of a variety of small devices.

  • PDF

Accuracy of the healing abutment and impression coping combined system on implant impression (인상채득이 가능한 치유지대주를 이용한 임플란트 인상채득의 정확성)

  • Jeon, Kyoung-Bae;Lee, Du-Hyeong;Kim, Jung-Han;Hwang, Jun-Ho;Park, Hyun-We;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • Purpose: The purpose of this study was to evaluate the 3 dimensional accuracy of impression taking on the newly developed healing abutment and impression coping combined system comparing conventional pick-up type impression. Materials and methods: For 10 patients who had a single missing tooth on molar area, dental implants (SuperLine; Dentium, Seoul, Korea) were placed and healing abutment (MyHealing; Raphabio Co., Seoul, Korea) abutments were connected. After 3 months, transfer type impression with MyHealing and pick-up type impression with impression coping were performed twice in the same patients, and master models were fabricated. Customized prosthetic abutments (Myplant; Raphabio Co., Seoul, Korea) were milled and connected to the master casts. Through a dental scanner (Scanner S600; Zirkonzahn, South Tyrol, Italy), the master casts were converted into virtual casts. The length and angulation differences between casts were measured using 3 dimentional analysis program (Geomagic Qualify 12; Geomagic, Morrisville, NC, USA). Statistical significance was calculated using Kruskal Wallis test and Mann-Whitney U test (${\alpha}$=.05). Results: The length differences between the two systems were 0.032 mm in sagittal plane, and 0.029 in coronal plane, and 0.023 mm in horizontal plane. The angulation differences were $0.755^{\circ}$ in sagittal plane, and $1.275^{\circ}$ in coronal plane, and $0.420^{\circ}$ in horizontal plane. Conclusion: The accuracy of newly developed healing abutment system is similar to that of conventional pick-up impression. The new system can reduces chair time by not using separate impression coping.