• Title/Summary/Keyword: Photo Detector

Search Result 196, Processing Time 0.037 seconds

Demonstration of Time- and Wavelength-Division Multiplexed Passive Optical Network Based on VCSEL Array

  • Mun, Sil-Gu;Lee, Eun-Gu;Lee, Jie Hyun;Park, Heuk;Kang, Sae-Kyoung;Lee, Han Hyub;Kim, Kwangok;Doo, Kyeong-Hwan;Lee, Hyunjae;Chung, Hwan Seok;Lee, Jong Hyun;Lee, Sangsoo;Lee, Jyung Chan
    • ETRI Journal
    • /
    • v.38 no.1
    • /
    • pp.9-17
    • /
    • 2016
  • We demonstrate a time- and wavelength-division multiplexed passive optical network system employing a vertical-cavity surface-emitting laser array-based optical line terminal transceiver and a tunable bidirectional optical subassembly-based optical network terminal transceiver. A packet error-free operation is achieved after a 40 km single-mode fiber bidirectional transmission. We also discuss an arrayed waveguide grating, a photo detector array based on complementary metal-oxide-semiconductor photonics technologies, and low-cost key devices for deployment in access networks.

Developing a simulator for Super-RENS/ROM disk using finite difference time domain method (Super-ROM/RENS 디스크 구조의 재생신호 해석을 위한 유한차분시간구역 (FDTD) 방법을 이용한 시뮬레이터 개발)

  • Ahn, Duck-Won;You, Chun-Yeol
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.2
    • /
    • pp.138-143
    • /
    • 2006
  • We developed a numerical simulator in order to study the Super-RENS/ROM (Super REsolution Near-Field Structure, Read Only Memory) using 3-dimensional FDTD (finite difference time domain) method. The simulation can be performed by three steps. In the first step, we utilized the vector-diffraction theory to calculate the characteristics of incident laser beam from the object-lens to the surface of the disk. At the second step, we fed the calculated result as an input for the main FDTD simulations on the optical layers in the disk structure. After performed the FDTD simulations, we took near-to-far field transformation for the reflected signal, from the surface of the disk to the detector. Finally, we can get reflected signal at the photo-diode. Using this developed simulator, we were able to study about the reading signal from various disk structures as a function of a laser beam position. We calculated reading signals for various pit sizes for Super-ROM structure, and it is found that the simple optical diffraction theory can not explain the reading mechanism of Super-ROM, and more complicated temperature dependent physics must be involved.

  • PDF

Estimation of Specular Light Power by Adjusting Incident Laser Power for Measuring Mirror-Like Surface Roughness (경면 거칠기 측정을 위해 레이저 입사 강도 조정에 의한 정반사 광량 추정 알고리즘 개발)

  • 서영호;김주년;안중환
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.6
    • /
    • pp.94-101
    • /
    • 2004
  • From the Beckmann's reflection model of wave incident, reflected light from a surface is known to have not only specular but also diffuse components. The specular component dominant a surface for a mirror-like surface is distributed on the almost the same area as the spot on the surface, but the diffuse component region dominant f3r a rough surface spreads scattered on the larger areas than the spot. Therefore, statistic parameters from the scattered light distribution are more meaningful in the diffuse region, while the magnitude of rather meaning in the specular region. In usual, there need two sensors to acquire two kinds of information: Photo-detector for light intensity magnitude and image sensor for light intensity distribution. But dual sensor scheme requires a beam splitter usually to feed light to each sensor, and moreover there is not a combination rule to relieve the different sensor characteristics. In this study a new method is proposed for acquisition of the dual information using only an image sensor. Specular region is established on an image area being distinguished from a diffuse component, and laser power is adjusted so that no pixel of the image sensor in the specular region is saturated. Simulation based on the light reflection theory and the experimental results are quite well matched, and thus the proposed method was proved to be very useful for mirror-like surface measurement.

Active Alignment and Performance Evaluation of Micro Hybrid Lens for Small Form Factor Optical Pickup (초소형 광 픽업용 하이브리드 렌즈의 능동 정렬 및 성능평가)

  • Kang, Sung-Mook;Lee, Jin-Eui;Cho, Eun-Hyoung;Sohn, Jin-Seung;Park, No-Cheol;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.2 no.1
    • /
    • pp.79-84
    • /
    • 2006
  • The next generation of optical storage systems requires higher numerical aperture(NA) objective lenses and shorter wavelength laser in order to improve the unit areal density. A blu-ray technology satisfies a miniaturization and a high capacity which are the requirements of the portable device. In this paper, we analyze the optical performance of hybrid micro lens and do active alignment. The hybrid micro lens is manufactured by using a wafer based fabrication technology. Optical components of hybrid micro lens are evaluated. The measurement of the optical power, the spot size and the wavefront error are performed to evaluate the hybrid micro lens with NA 0.85. Using the measured data, we estimate if the performance of hybrid micro lens corresponds to the designed performance. After the performance of hybrid micro lens is evaluated. the integrated optical pickup and the hybrid micro lens are assembled by active alignment using UV curing and the optical performance of SFFOP is satisfied with BD specifications.

  • PDF

Design of 2-axis compensation servo system for angle multiplexing Holographic Data Storage (각 다중화 방식의 홀로그래픽 정보저장기기의 양방향틸트 보상시스템 설계)

  • Lim, Sung-Yong;Kim, Nak-Yeong;Han, Cho-Lok;Park, Kyoung-Su;Park, No-Cheol;Yang, Hyun-Seok;Park, Young-Pil
    • Transactions of the Society of Information Storage Systems
    • /
    • v.7 no.1
    • /
    • pp.19-24
    • /
    • 2011
  • Holographic Data Storage System, one of the next generation data storage devices, is a 2-dimensional page oriented memory system using volume holograms in writing and retrieving process. Recently photopolymer with disc type substrate was selected as a media for the Holographic Data Storage System. The disc tilt occurs when the media rotates and the external disturbance applies. The disc tilt causes the change of the angle between the reference beam and the media, the data cannot be retrieved with the right angle or other data page is retrieved. The tilt is generated in a 2-axis direction (tangential, radial). The tangential tilt direction is the same with the multiplexing plane, while the radial tilt direction is a perpendicular to the multiplexing plane. In this research we propose 2-axis tilt angle servo system. The tilt errors are measured by using external photo detector and the additional red laser. Then the tangential direction tilt is compensated by using the galvano mirror. Also the radial direction tilt is compensated by the rotating prism between the relay lens in the reference field. Finally we confirm the compensation results through the Signal to Noise Ratio(SNR) and Bit Error Rate(BER).

A survey on pesticide residues of imported fruits circulated in Gyeonggido (경기도내 유통 수입과실류의 잔류농약 실태조사)

  • Cho, Yun-Sik;Kang, Jeong-Bok;Kim, Yang-Hee;Jeong, Jin-A;Huh, Jeong-Weon;Lee, So-Hyun;Lim, Young-Sik;Bae, Ho-Jeong;Kang, Heung-Gyu;Lee, Jeong-Hee;Jung, Eun-Sook;Lee, Byoung-Hoon;Park, Yong-Bok;Lee, Jong-Bok
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.3
    • /
    • pp.195-201
    • /
    • 2012
  • We tested for pesticide residues in 124 samples of 22 different items of imported fruits circulated in Gyeonggido. Total 218 pesticides were analyzed by multi-residue method using gas chromatography/nitrogen phosphorus detector-electron capture detector (GC/NPD-ECD), time of flight/mass spectrometer (TOF/MS), ultra performance liquid chromatography/photo diode array (UPLC/PDA), high performance liquid chromatography/fluorescence detector (HPLC/FLD) and mass spectrometer (LC/MS/MS). The pesticides were detected in 18 fruits samples, ranging 0.003~0.3 mg/kg and no samples had violative residue. The separation test to 14 sample pesticides detected was conducted to monitor the current status of pesticide residues according to the partial characteristic. The pesticides were detected in 14 peels ranging 0.03~1.5 mg/kg and 2 fleshes in less than detection limits. These results indicate that imported fruits are safe when the human takes normally but even the small amount of pesticides is harmful when the human takes it in a prolonged period. Therefore, the pesticide residual amounts of imported friuts should be constantly monitored for food safety.

A Study on Signal Analysis of the Data Aquisition System for Photosensor (데이터 획득장치에 이용되는 포토센서에 대한 DAS의 신호분석연구)

  • Hwang, InHo;Yoo, Sun Kook
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.3
    • /
    • pp.237-242
    • /
    • 2016
  • The major advantage of slip-ring technology in Spiral CT is that it facilitates continuous rotation of the x-ray tube, so that volume data can be acquired from a patient quickly. Not only for such a fast scan, but also for the dose reduction purpose, high signal-to-noise ratio and fast data acquisition system is required. In this study, we have built a multi-channel photodetector and multi-channel data acquisition system for CT application. The detector module consisted of CdWO4 crystal and Si photodiode in 16 channels. For the performance test of the preamplifier stage, both the transimpedance and switched integrator types are optimized for the photodetector modules. Switched integrator showed better noise performance in the limited bandwidth which is suitable for the current CT application. The control sequence for data acquisition and 20 bit ADC is designed with VHDL(Very High Speed Integrated Circuit Hardware Description Language) and implemented on FPGA(Field Programmable Gate Array) chip. Our Si photodiode detector module coupled to CdWO4 crystal showed comparable signal with other commercially available photodiode for CT. Switched integrator type showed higher SNR but narrower bandwidth compared to transimpedance preamplifier. Digital hardware is designed by FPGA, so that the control signal could be redesigned without hardware alteration.

Simultaneous Identification/Determination System for Sildenafil, Homosildenafil, Vardenafil and Tadalafil as Adulterants in Foods (식품중 불법함유된 발기부전치료제 성분 검출을 위한 동시분석법 연구)

  • Jang, Jae-Hee;Park, Kun-Sang;Park, Hye-Kyung;Koo, Yong-Eui;Choi, Youn-Ju;Hwang, In-Kyung;Kim, Dai-Byung
    • Journal of Food Hygiene and Safety
    • /
    • v.18 no.4
    • /
    • pp.195-201
    • /
    • 2003
  • An easily available, simultaneous identification/determination procedure for sildenafil, homosildenafil, tadalafil, vardenafil in adulterated health related foods was established by using a combination of three different analytical methods; thin layer chromatography(TLC), liquied chromatography-mass spectrometry (LC/MS) and high-performance liquied chromatography (HPLC)/photo-diode-array detector. The sample solution for TLC was applied to silica gel 60 $F_{254}$ plates with ethylacetate/acetonitrile/25%ammonia (90:10:5) as a developing solvent. Spots were located under UV radiation at 254 nm and dragendolfs reagent. Mass spectra of the compounds by LC/MS were investigated with electrospray ionization (ESI) interface, under positive ion mode. The HPLC analysis was performed on a column of capcell pack $C_{18}$ (UG120, 4.6${\times}$250mm I.D. 5 ${\mu}$m)with 0.1% sodium 1-hexansulfonate (in 0.1% phosphoric acid)/acetnitrile (73:27) as a mobile phase, and effluent was minitored with a photo-diode-applied to commercial foods, Sildenafil content was inthe range of 0.4mg/g~360.9 mg/g from 7 out of 35 samples. Homosildenafil content was in the range of 2.2 mg/g~336.0 mg/g from 7 out of 35 samples. Tadalafil content was 429.3 mg/g, 9.6 mg/500 mg from 2 out of 35 samples. The procedure described here is available for the screening of sildenafil, homosildenafil, tadalafil, vardenafil.

A Study on THz Generation and Detection Characteristics of InGaAs Semiconductor Epilayers (InGaAs 반도체 박막의 테라헤르쯔(THz) 발생 및 검출 특성 연구)

  • Park, D.W.;Kim, J.S.;Noh, S.K.;Ji, Young-Bin;Jeon, T.I.
    • Journal of the Korean Vacuum Society
    • /
    • v.21 no.5
    • /
    • pp.264-272
    • /
    • 2012
  • In this paper, we report THz generation and detection characteristics investigated by InGaAs semiconductor epilayers, as results of a basic study obtained from the InGaAs-based THz transmitter/receiver (Tx/Rx). High-temperature and low-temperature (LT) grown InGaAs epilayers were prepared by the molecular beam epitaxy technique for the characterization of THz generation and detection, respectively, and the surface emission based on the photo-Dember effect was tried for THz generation. THz wave was generated by irradiation of a Ti:Sapphire fs pulse laser (60 ps/83 MHz), and a LT-GaAs Rx was used for the THz detection. The frequency band shown in the spectral amplitudes Fourier-transformed from the measured current signals was ranging in 0.5~2 THz, and the signal currents were exponentially increased with the Tx beam power. The THz detection characteristics of LT-InGaAs were investigated by using an Rx with dipole (5/20 ${\mu}m$) antenna, and the cutoff frequency was ~2 THz.

The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide (레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발)

  • Lee, Sang-Won;Kim, Wi-Han;Jung, Young-Dae;Park, Min-Kyu;Kim, Jee-Hyun;Lee, Sang-In;Lee, Ho
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.46-52
    • /
    • 2011
  • A confocal microscope was developed utilizing a scanning sample stage based on a home-built double-compound flexure guide. A scanning sample stage with nano-scale resolution consisted of a double leaf spring based flexure, a displacement amplifying lever, a Piezo-electric Transducer(PZT) actuator and capacitance sensors. The performance of the two-axis stage was analyzed using a commercial finite element method program prior to the implementation. A single line laser was employed as the light source along with the Photo Multiplier Tube(PMT) that served as the detector. The performance of the developed confocal microscope was evaluated with a mouse ear skin imaging test. The designed scanning stage enabled us to build the confocal microscope without the two optical scanning mirror modules that are essential in the conventional laser scanning confocal microscope. The elimination of the scanning mirror modules makes the optical design of the confocal microscope simpler and more compact than the conventional system.