• 제목/요약/키워드: Performance increase

검색결과 11,604건 처리시간 0.038초

Theoretical investigation about the hydrodynamic performance of propeller in oblique flow

  • Hou, Lixun;Hu, Ankang
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제11권1호
    • /
    • pp.119-130
    • /
    • 2019
  • This paper establishes an iterative calculation model for the hydrodynamic performance of propeller in oblique flow based on low order potential based surface panel method. The hydrodynamic performance of propeller is calculated through panel method which is also used to calculate the induced velocity. The slipstream of propeller is adjusted according to the inflow velocity and the induced velocity. The oblique flow is defined by the axial inflow velocity and the incident angle. The calculation results of an instance show that the thrust and torque of propeller decrease with the increase of axial inflow velocity but increase with the incident angle. The unsteadiness of loads on the propeller blade surface gets more intensified with the increases of axial inflow velocity and incident angle. However, comparing with the effect of axial inflow velocity on the unsteadiness of the hydrodynamic performance of propeller, the effect of the incident angle is more remarkable.

A novel high performance diffuser design for small DAWT's by using a blunt trailing edge airfoil

  • Alanis, Arturo;Franco, Jesus Alejandro;Piedra, Saul;Jauregui, Juan Carlos
    • Wind and Structures
    • /
    • 제32권1호
    • /
    • pp.47-53
    • /
    • 2021
  • This paper proposes a novel diffuser design for Diffuser Augmented Wind Turbines (DAWT) based on the blunt trailing edge airfoil AF300. Computational Fluid Dynamics (CFD) simulations are carried out to measure the performance of the AF300 diffuser against diffusers made with the shape of other high performance low wind speed airfoils. The results show that the proposed diffuser produces a greater air mass flow increase through the plane of the turbine than the other diffusers and it can be used to increase the performance of a horizontal axis wind turbine.

Performance evaluation of suspended ceiling systems using shake table test

  • Ozcelik, Ozgur;Misir, Ibrahim S.;Saridogan, Serhan
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.121-142
    • /
    • 2016
  • The national standard being used in Turkey for suspended ceiling systems (SCS) regulates material and dimensional properties but does not contain regulations regarding installation instructions which cause substandard applications of SCSs in practice. The lack of installation instructions would potentially affect the dynamic performance of these systems. Also, the vast majority of these systems are manufactured using substandard low-quality materials, and this will inevitably increase SCS related damages during earthquakes. The experimental work presented here focuses on the issue of dynamic performance of SCSs with different types of carrier systems (lay-on and clip-in systems), different weight conditions, and material-workmanship qualities. Moreover, the effects of auxiliary fastening elements, so called seismic perimeter clips, in improving the dynamic performance of SCSs were experimentally investigated. Results show that clip-in ceiling system performs better than lay-on system regardless of material and workmanship qualities. On the other hand, the quality aspect becomes the most important parameter in affecting the dynamic performance of lay-on type systems as opposed to tile weights and usage of perimeter clips. When high quality system is used, tile weight does not change the performance of lay-on system, however in poor quality system, tile weight becomes an important factor where heavier tiles considerably decrease the performance level. Perimeter clips marginally increase the dynamic performance of lay-on ceiling system, but it has no effect on the clip-in ceiling system under the shaking levels considered.

골관절염 여성의 임상적 특성 및 자기효능감이 기능수행에 미치는 영향 (The Influence of Clinical Symptoms and Self-Efficacy on Function in Women With Osteoarthritis)

  • 정경아;이완희
    • 한국전문물리치료학회지
    • /
    • 제14권1호
    • /
    • pp.55-63
    • /
    • 2007
  • This study was designed to examine the relationship between clinical symptoms, self-efficacy, and performance of women with osteoarthritis. It is a survey study of 60 women who were diagnosed as osteoarthritis and given medical treatments from September, 2005 to October, 2005 in hospital 'H' located in Yongin-si. For clinical symptoms, radiographs of the subjects' knees were taken and evaluated the pathology grade by the Kellgren-Lawrence grade. Pain and stiffness was measured by the measure of WOMAC (Western Ontario and McMaster Universities Osteoarthritis Index), and functional reach test was measured in order to examine balancing abilities. Self-efficacy was measured by a tool which has revised the ASES (Arthritis Self-Efficacy Scale), and performance was measured by recording the difficulty of the WOMAC measurements themselves, and the time taken for 20 m walking, going up and down 9 stairs, and 5 sit-down and stand-up repetitions. The resulting differences in the other variables according to performance and the relationship between performance with variables are the following. First, an increase in pain in women with osteoarthritis led to decreased functional ability. Second, an increase in stiffness in women with osteoarthritis led to a decrease in functional ability. Third, a decrease in balance in women with osteoarthritis led to a decrease in functional ability. Fourth, a decrease in self-efficacy in women with osteoarthritis led to a decrease in functional ability. Fifth, the variables for estimating the performance by self-report were pain and self-efficacy. The variables for estimating the performance by recording the time taken was balance and self-efficacy. As a result factors such as pain, balance and self-efficacy in women with osteoarthritis were closely related to performance. Based on the results, it seems that physical therapy programs to decrease pain and to increase the balance in women with osteoarthritis, and psychological approaches to increasing self-efficacy are needed. I hope that the results of this study will be useful data for clinical management and intervention for women with osteoarthritis.

  • PDF

Factors Affecting Health Worker Performance: A Management Evidence from Midwife Sharia Hospital X in Central Java Indonesia before the Covid-19 Pandemic

  • ADINUGRAHA, Hendri Hermawan;TANJUNG, Dwike Sekar;RISMAWATI, Shinta Dewi;MA'SHUM, A.M. Hafidz;ISMANTO, Kuat;ARWANI, Agus;DEVY, Happy Sista;DZULFIKAR, Ahmad;ROHMAH, Farida;ROSYADA, Mohammad;WINARTO, Wahid Wachyu Adi
    • 식품보건융합연구
    • /
    • 제7권3호
    • /
    • pp.13-23
    • /
    • 2021
  • The purpose of this study was to explain the influence of motivation, leadership, and discipline on the performance of the midwife at Sharia Hospital X in Central Java Indonesia before the Covid-19 pandemic. This research is a combination between quantitative research and qualitative research (mix method). The population in this study were all midwives sharia hospital x in central java Indonesia, totaling 75 people. The primary data in this study came from questionnaires, interviews, observation, and documentation, then from the results of the analysis and data processing the researcher interpreted it more deeply using qualitative methods. The results of this study conclude that motivation, leadership, and discipline are proven to have a positive and significant effect on the performance of midwives, thus it can be concluded that an increase in motivation, leadership, and discipline in work will be able to improve the performance of the midwifes Sharia Hospital X. These results give an understanding that every time there is an increase in motivation, leadership, and work discipline, it will increase the performance of the midwifes. Motivation is the biggest variable affecting the performance, leadership is the second and work discipline is the smallest variable that affects the performance of midwives.

Engineering Properties of Steel Fiber Reinforced High Performance Concrete

  • Kim Young Ik;Sung Chan Yong
    • 한국농공학회논문집
    • /
    • 제46권7호
    • /
    • pp.55-67
    • /
    • 2004
  • In this paper, the flowability, strengths, impact resistance and sulfuric acid resistance of steel fiber reinforced high performance concrete (SFHPC) for the steel fiber content and fly ash and blast furnace slag as admixtures were presented. For evaluating flowability particularly, tests of slump flow, box-type passing ability and L-type filling ability were performed. The slump flow of SFHPC was some decreased with increase of the steel fiber content. At the box-type passing ability, the difference of box height of SFHPC is greatly increased with increasing the fiber content. The L-type filling ability of SFHPC was not excellent above $0.75\% of the steel fiber content. Also, the compressive strength of SFHPC was decreased with increase of the steel fiber content, but the flexural strength of SFHPC was much higher than that of the concrete without the steel fiber. At the impact resistance, drop number of SFHPC for reaching final fracture was increased with increase of the fiber content. Also, the drop number for reaching initial fracture of lmm was increased with increase of the fiber content. At the sulfuric acid resistance, 4-week weight change of SFHPC with the steel fiber was almost similarity that of HPC without the steel fiber and was in the range of 73.6 to 81.5.

실험실적 규모의 분무흡수건조반응기의 배출가스 중 아황산가스 처리성능 연구 (Flue Gas Sulfur Dioxide Removal Performance of a Bench-Scale Spray Absorption/Drying Reactor)

  • 동종인;구우회;임대현
    • 한국대기환경학회지
    • /
    • 제12권4호
    • /
    • pp.449-457
    • /
    • 1996
  • The main purpose of this study was to investigate sulfur dioxide removal performance of flue gas desulfurization system utilizing a Spray Absorption/Drying Reactor. In this system, the size of droplets was considered the most significant factor and tested using a PDA system. Lime slurry flow rate, operating temperature, calcium/sulfur (Ca/S) ratio and applied air pressure were selected as major operation variables and tested/analyzed in terms of system performance. The results are as follows. 1. The $SO_2$ removal efficiencies were 49%, 74%, 85% for Ca$(OH)_2$ slurry flow rate of 10, 20, 30 ml/min, which implies that the increase of slurry flow rate improves removal efficiency. The optimum slurry flow rate in this study was, however, considered 20 ml/min because of constraints of system troubles and absorbent utilization. 2. As Ca/S ratio increased, $SO_2$ removal efficiency was observed to increase. 3. As air pressure, at the atomizing nozzole, increased from 3 to 5 $kg/cm^2, SO_2$ removal efficiency increased from 74% to 80%, because of droplet size reduction due to pressure increase during atomizing process and the increase of surface area, helping mass transfer between gas and liquid phase.

  • PDF

Performance of a Foam Fractionator in a Lab-scale Seawater Recirculating Aquaculture System

  • Peng Lei;Jo Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • 제6권4호
    • /
    • pp.187-193
    • /
    • 2003
  • The performance of a foam fractionator to remove TAN, $NO_2,\;NO_3$, TSS, protein, and $PO_4-P$ at different superficial air velocities and foam overflow heights was evaluated in a lab-scale seawater recirculating system for culture of Korean rockfish (Sebastes schlegeli). The foam overflow rates increased with the increase of superficial air velocities, but decreased with the increase of foam overflow heights. Concentrations of all the water quality variables in the foam condensates increased with the increase of foam overflow height, but decreased with the increase of superficial air velocities. TSS, protein, and phosphate enrichment factors were within the range of 6.4-39.4, 1.6-7.3 and 1.2-3.9, respectively. Low values of TAN, $NO_2,\;and\;NO_3$ enrichment factors were obtained and they indicate that foam fractionation is rot an effective way to remove dissolved inorganic nitrogen. The calculated maximum daily removal values for TSS and protein were 10.9 and 1.4g, respectively.

3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

다결정 실리콘 박막 트랜지스터의 성능에 대한 채널 길이의 영향 (Influence of Channel Length on the Performance of Poly-Si Thin-Film Transistors)

  • 이정석;장창덕;백도현;이용재
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.450-453
    • /
    • 1999
  • In this paper, The relationship between device performance and channel length(1.5-50$\mu$m) in polysilicon thin-film transistors fabricated by SPC technology was Investigated by measuring electric Properties such as 1-V characteristics, field effect mobility, threshold voltage, subthreshold swing, and trap density in grain boundary with channel length. The drain current at ON-state increases with decreasing channel length due to increase of the drain field, while OFF-state current (leakage current) is independent of channel length. The field effect mobility decrease with channel length due to decreasing carrier life time by the avalanche injection of the carrier at high drain field. The threshold voltage and subthreshold swing decrease with channel length, and then increase in 1.5 $\mu$m increase of increase of trap density in grain boundary by impact ionization.

  • PDF