• Title/Summary/Keyword: Panel inspection

Search Result 172, Processing Time 0.026 seconds

The Bond Performance of RC Beams Strengrhened for FRP Pannel deal with Fatigue Loadings through Experiments (실험에 의한 피로하중을 받는 FRP패널 보강 RC보의 부착성능)

  • Lee, Chang Gyu;Chung, Yung Bea
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.3
    • /
    • pp.105-115
    • /
    • 2007
  • Repair and Reinforcement are subjected change to increasing of remodelling. The usage of carbon fiber sheets is increasing for the strengthening of reinforce concrete structures. Therefore experimental and analytical studies are carry out to investigate the flexural behaviors of the strengthened RC structures by the external bonding of the new reinforcement method. Also the aim of this study is to investigate reinforcing method of FRP panel deal with fatigue loading through experiments.

Development of Unmanned Cleaning Robot for Photovoltaic Panels (태양광발전시설 무인 유지보수 로봇 개발)

  • Lee, Hyungyu;Lee, Sang Soon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.3
    • /
    • pp.144-149
    • /
    • 2019
  • This paper describes the results of a study on the unmanned maintenance robot that simultaneously performs the cleaning and inspection of the photovoltaic panels. The robot has a special adsorptive device, an infrared sensor, a vacuum level sensor and a camera. The robot uses two SSC (Sliding Suction Cup) adsorptive devices to move up and down the slope. First, the forces generated when the robot moves up the slope are mechanically analyzed, and the required design and control of the adsorption system are suggested. The robot was designed and manufactured to operate stably by using the presented results. Next, the normal force between the panel and the wheel was measured to confirm that the robot was manufactured and operated as intended, and the robot motion was tested on the inclined panel. It has been proven that robots are well designed and built to clean and inspect sloped panels.

Development of Vision system for Back Light Unit of Defect (백라이트 유닛의 결함 검사를 위한 비전 시스템 개발)

  • Han, Chang-Ho;Oh, Choon-Suk;Ryu, Young-Kee;Cho, Sang-Hee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.55 no.4
    • /
    • pp.161-164
    • /
    • 2006
  • In this thesis we designed the vision system to inspect the defect of a back light unit of plat panel display device. The vision system is divided into hardware and inspection algorithm of defect. Hardware components consist of illumination part, robot-arm controller part and image-acquisition part. Illumination part is made of acrylic panel for light diffusion and five 36W FPL's(Fluorescent Parallel Lamp) and electronic ballast with low frequency harmonics. The CCD(Charge-Coupled Device) camera of image-acquisition part is able to acquire the bright image by the light coming from lamp. The image-acquisition part is composed of CCD camera and frame grabber. The robot-arm controller part has a role to let the CCD camera move to the desired position. To take inspections of surface images of a flat panel display it can be controlled and located every nook and comer. Images obtained by robot-arm and image-acquisition board are saved on the hard-disk through windows programming and are tested whether there are defects by using the image processing algorithms.

Impact Damage of Honeycomb Sandwich Antenna Structures (통신 안테나용 허니콤 샌드위치 구조물의 충격 손상에 관한 연구)

  • 조성재;김차겸;박현철;황운봉
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.74-77
    • /
    • 2001
  • The impact response and damage of CLAS panel was investigated experimentally. The facesheet material used was RO4003 woven-glass hydrocarbon/ceramic and the core material was Nomex honeycomb with a cell size of 3.2mm and a density of 96 kg/$\textrm{m}^{3}$. The shield plane used was RO4003 and 2024-T3 aluminum. Static indentation and impact test was conducted to characterize the type and extent of the damage observed in two CLAS panels, and the performance of antenna used in a wireless LAN system. Correlation of peak contact force, residual indentation and the delamination area shows impact damage of the panel with an aluminum shield plane is larger than that of the panel with RO4003 shield plane, although tile former is more penetration resistant. The damage was observed by naked eye, ultrasonic inspection and cross sectioning. The shape and size of delamination was estimated by ultrasonic inspection, and the area of delamination linearly increases as impact energy increases. The performance of impact damaged antenna was estimated by measuring return loss and radiation pattern.

  • PDF

Fire Resistance Performance of Load Bearing Hybrid Panel Infilled with Light-weight Formed Mortar (복합스터드에 경량기포모르터를 충전한 내력벽체의 내화성능 비교연구)

  • Park, Keum Sung;Bae, Kyu Woong;Kang, Hyun Sik;Lim, Seo Hyung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.11 no.2
    • /
    • pp.109-116
    • /
    • 2007
  • The purpose of this paper is to evaluate the fire resistant performances of load-bearing wall using both composite and steel stud panel infilled with light-weight formed mortar under axial loading according to KS F 2257(1999). The minimum requirement of 2 hours fire resistant rating is needed for the residential and commercial buildings under the fire regulation of Korea. From test results, it is found that two types of specimen composed of the hybrid stud and steel stud panel filled with light-weight formed mortar fited in with the requirement of 2 hours fire resisting rate for the load-bearing wall. In the conclusions, the specimen with hybrid stud shows predominating fire-resistant performance on the adiabatic effects rather than that of the steel stud specimen.

A Study on Inspection Technology of PDP ITO Defect (PDP ITO 결함 검출기술에 관한 연구)

  • 송준엽;박화영;정연욱;김현종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.191-195
    • /
    • 2003
  • The formation degree of sustain (ITO pattern) decides quality of PDP (plasma display panel). For this reason. it makes efforts in search defects more than 30 ${\mu}{\textrm}{m}$. Now, the existing inspection process is dependent upon naked eye or SEM equipment in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP ITO glass. This system creates information that detects and sorts kind of defect automatically. Design ed inspection technology adopts line-scan method by slip-beam formation for the minimum of inspection time and image processing algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix which draws up an approach to geometry. A characteristic of area-shaped defects, as pin hole, substance, protrusion et al, are extracted from blob analysis method. Defects, as open, short, spots, et al, are distinguished by line type inspection algorithm. In experiment results, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds

  • PDF

Behavior Monitoring of Precast Concrete Panels in Lifting (프리캐스트 패널의 양중에 따른 거동 계측 연구)

  • Yang, Sung Chul;Kim, Seong Min;Han, Seung Hwan;Yoon, Sang Chun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.16 no.3
    • /
    • pp.51-59
    • /
    • 2012
  • Through this research safety factors were analyzed for concrete precast panels in road pavement which happens in lifting, moving, and installing. Two half size of full-scale precast concrete panels were made while one full-scale precast concrete panel was made. A series of strain gages for concrete and steel were installed and measured in lifting and transporting. Measurement results indicate that in case of 60 degree of lifting, small scale panel in dynamic motion produces about 3.54 times of strain compared to the static condition. However strain measurement of full-scale concrete panel in lifting and transportation does not yield any big difference compared to the small scale panels in the static condition. From this experimental results safety of the full-scale concrete panel was attained for the lifting system adopted in this research.

Development of Defect Inspection System for PDP ITO Patterned Glass (PDP ITO 패턴유리의 결함 검사시스템 개발)

  • Song Jun Yeob;Park Hwa Young;Kim Hyun Jong;Jung Yeon Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.12
    • /
    • pp.92-99
    • /
    • 2004
  • The formation degree of sustain (ITO pattern) decides quality of PDP (Plasma Display Panel). For this reason, it makes efforts in searching defects more than 30 un as 100%. Now, the existing inspection is dependent upon naked eye or microscope in off-line PDP manufacturing process. In this study developed prototype inspection system of PDP 170 glass is based on line-scan mechanism. Developed system creates information that detects and sorts kinds of defect automatically. Designed inspection technology adopts multi-vision method by slip-beam formation for the minimum of inspection time and detection algorithm is embodied in detection ability of developed system. Designed algorithm had to make good use of kernel matrix that draws up an approach to geometry. A characteristic of defects, as pin hole, substance, protrusion, are extracted from blob analysis method. Defects, as open, short, spots and et al, are distinguished by line type inspection algorithm. In experiment, we could have ensured ability of inspection that can be detected with reliability of up to 95% in about 60 seconds.

NOVEL SURFACE PROFILER SYTSTEM FOR INSPECTION OF FLAT PANEL DISPLAY

  • Kimura, Munehiro;Akahane, Tadashi;Iwata, Tetsuya
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.325-327
    • /
    • 2004
  • Novel surface profiler system for inspection of the display components is demonstrated In the case of the liquid crystal display, for example, not only the flatness of the alignment film but also the quality of rubbing can be inspected. Furthermore, the shape of the component such as the color filter, electrode and mirror can be inspected without removing each component.

  • PDF

Gradient-based Fast Connectivity Weighted Hough Transform (그래디언트 기반 고속 연결성 가중 허프 변환)

  • Kim, Jeong-Tae;Shin, Ji-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.4
    • /
    • pp.715-717
    • /
    • 2008
  • The connectivity weighted Hough transform is a useful method for detecting well-connected short lines without generating false lines yet requires extensive computation. This letter describes a method that reduces the computation of the connectivity weighted Hough transform by removing unnecessary weight calculations using the gradient angles of feature points. In simulations with synthetic images and experiments with liquid crystal display panel images, the proposed method showed significantly improved speed without compromising detectability.