• 제목/요약/키워드: PREVENT THE INFLOW

검색결과 120건 처리시간 0.034초

제주도 관정 공벽 내 오염물질 유입 구간 탐지 및 차단 사례 (Case for Detection and Prevention of Inflow Section for Contaminant through Annular Space in Borehole, Jeju Island)

  • 송성호;황보동준;김진성;양원석
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제27권3호
    • /
    • pp.1-10
    • /
    • 2022
  • Most wells developed in Jeju island before the enactment of the Groundwater Management Ordinance in 2002 are vulnerable to aquifer contamination due to inflow of upper groundwater having the high concentration of nitrate nitrogen, likely due to incomplete grouting in upper section of the wells. Although these wells require entire reinstallation, it is often necessary to rehabilitate the existing wells due to various constraints. Therefore, to identified the inflow section of contaminants, the thermal level sensor (TLS) technique was firstly applied for three wells, which enables to monitor temperature variations in every 50 cm depth. Then, the grouting material was injected to the upper section to prevent the inflow of upper contaminated groundwater into the entire aquifer. By applying TLS technique, it was found that the temperature deviations in the upper groundwater inflow section decreased sharply. Moreover, both the change in the concentration of nitrate nitrogen in the rainy/dry seasons and the average concentrations were found to decrease rapidly after grouting material injection. Consequently, the application of TLS proposed in the study turned out to be appropriate to prevent aquifer contamination.

선택취수설비 굴착시 지하수 유입 방지를 위한 그라우팅 효과의 모델링 예측 및 평가 (Forecasting and Assessment of the Grouting Effect, using a Numerical Model, to Prevent Groundwater Inflow during Excavation of a Vertical Shaft for a Selective Intake Structure)

  • 김규범;김완수;박정훈;손영철;김진우
    • 지질공학
    • /
    • 제23권3호
    • /
    • pp.227-234
    • /
    • 2013
  • 대규모 저수지에서 상수원 선택취수설비의 수직구 굴착시 저수지 및 주변 지층으로부터의 지하수 유입이 발생할 수 있어 그라우팅을 통한 차수가 요구된다. 본 연구에서는 소양강댐 우안의 선택취수설비 공사 중에 발생할 수 있는 지하수 유입량을 그라우팅 실시 여부에 따라 모사하고 시공 중의 실제 유입량과 비교하였다. 수직구에 그라우팅이 시공되지 않은 경우에는 445~754 $m^3/d$, 그라우팅이 시공된 경우에는 58~96 $m^3/d$의 지하수가 수직구내로 유입되는 것으로 예상되었으며, 실제 그라우팅을 거친 후 굴착 과정에서 배출된 지하수량을 측정한 결과 30~100 $m^3/d$의 범위를 보여 예측 수량과 유사한 것으로 나타났다. 수직구의 작업 안정성 확보 및 원활한 공정을 위해서는 수치모델을 활용한 그라우팅 효과의 사전 평가가 필요하며 이를 근거로 그라우팅 시공을 선행한 후 굴착이 진행되는 것이 필요하다.

장기 기상전망이 댐 저수지 유입량 전망에 미치는 영향 분석 (An analysis of effects of seasonal weather forecasting on dam reservoir inflow prediction)

  • 김선호;남우성;배덕효
    • 한국수자원학회논문집
    • /
    • 제52권7호
    • /
    • pp.451-461
    • /
    • 2019
  • 장기 기상전망 기반 댐 유입량 전망은 가뭄 대비, 용수 공급 관리 등에 활용성이 높다. 본 연구에서는 국내 7개 다목적댐 유역에 대해 유입량 전망을 수행하고 장기 기상전망 정확도가 댐 유입량 전망 정확도에 미치는 영향을 분석하였다. 강우-유출 모델의 입력자료로 활용된 장기 기상전망 자료는 기상청 GloSea5의 과거재현자료(hindcast) 및 미래전망자료(forecast)를 활용하였다. 강우-유출 모델은 다양한 특성을 가지고 있는 TANK, ABCD, K-DRUM, PRMS를 활용하였다. 댐 유입량 전망 정확도는 과거재현기간(1996~2009)과 미래전망기간(2015~2016)에 대하여 평가하였다. 댐 유입량 전망 평가결과 전망값은 관측값에 비해 과소추정하는 경향을 보였으며, 매개변수 검보정이 적절히 수행된 강우-유출 모델은 댐 유입량 전망 정확도에 미치는 영향이 거의 없는 것으로 나타났다. 반면 장기 기상전망 자료, 특히 강수량은 댐 유입량 전망 정확도에 매우 큰 영향을 미치는 것으로 나타났다. 현업에서 댐 유입량 전망 자료 활용시 과소추정하는 경향을 고려하여 활용할 필요가 있다. 향후 댐 유입량 전망 정확도 개선은 강우-유출 모델 보다 장기 기상전망의 강수량 정확도 향상을 위주로 수행할 필요가 있다.

하수관거 I/I(침입수/유입수) 분석방법에 따른 산정 결과 비교 -기존 보정방법과 환경부 표준 매뉴얼에 의한 방법- (Analysis on the result of I/I calculation by the exiting method and the standardized maual method)

  • 안병모;송호면
    • 상하수도학회지
    • /
    • 제25권2호
    • /
    • pp.213-221
    • /
    • 2011
  • The purpose of sewer system is to separate rain water from sewage water. Through this, it is possible to prevent the flood and preserve public water territory. For the past few years, many problems of the sewer system have been solved by the execution of sewer rehabilitation project. However, they still exist in sewer system caused by I/I, which are divided into infiltration and inflow. Infiltration means the rain water and underground water that infiltrate through breakage point on pipes, inflow means the water that flows in through misconnection on pipes. This study shows how the I/I calculation has changed according to the new standardized manual and identifies the I/I difference between the new calculation and the existing one. Through the analysis on the two calculation methods we examined the appropriacy of the new method by comparing it to the old one. The result points out that the new standardized manual is more appropriate than the old in aspect of objectivity and reproducibility(establish standardization), rationality(alteration of inflow unit).

안트라사이트를 혼입한 시멘트 보드의 라돈흡착 특성 (Radon adsorption properties of cement board using anthracite)

  • 경인수;편수정;이상수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2018
  • Among the recent environmental pollution, indoor air pollution has an adverse effect on the health of indoor residents. Radon, one of the causes of indoor air pollution, is released from concrete, gypsum board and asbestos slate among building materials. Radon is a primary carcinogen and is a colorless, tasteless, odorless inert gas that adheres to airborne dust and enters the body through breathing. At this time, there is a risk of developing cancer if the alpha rays from the lononggas entering the human body destroys the lung tissue and is continuously exposed to a high concentration of lonon gas. The World Health Organization (WHO) has emphasized the reduction of radon and its exposure to radon by classifying it as a first-level carcinogen, but many people have not recognized it yet, and the research is underdeveloped. Therefore, this study was carried out to investigate the properties of adsorbed coconut radon to prevent the inflow of radon gas, which is an air pollution source of indoor air, and to prevent inflow into the human body.

  • PDF

통신장비실의 열환경 개선방안에 관한 연구 -TDX-10, TDX-100, 5ESS-2000, PCM실 중심으로- (A Study for Improving the Thermal Environment of Telecommunication Equipment Room -based on TDX-10, TDX-100, 5ESS-2000, PCM room-)

  • 조춘식;이승복
    • KIEAE Journal
    • /
    • 제4권3호
    • /
    • pp.87-94
    • /
    • 2004
  • The purpose of this study is to improve thermal environment of telecommunication equipment rooms that hold TDX-10, TDX-100, 5ESS-2000, PCM of the latest telecommunication equipment. Analysis program is used the commercial CFD code, Star-CD and DOE-2.1E. The result has been compared by the energy consumption and the temperature contour at the 1 m height of room for each case. Different methods such as the relocation of the existing air-conditioner, the inflow of the ambient air into room, the installation of the forced fan and the cooling system equipment of the duct-connection type have been used to test for improvement of thermal environment. The analysis shows that most efficient method is the inflow of the ambient air into room but auxiliary equipment should be needed to prevent the local thermal spot.

한강 단층대를 통과하는 하저터널의 안정성 확보에 관한 연구 (Stability Evaluation for a riverbed tunnel in the Han River at the Fault Zone Crossing)

  • 우종태;이송
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제5권3호
    • /
    • pp.225-231
    • /
    • 2001
  • When building tunnels beneath riverbeds where very large quantities of groundwater inflow exist, added to high water head the soil supporting conditions are very poor because the soil consists of sand and silt, etc. It is necessary to have grouting and mini pipe roof installed in the region for ground reinforcement to decrease permeability. According to this result of horizontal boring and laboratory soil testing, ground reinforcement was achieved by L.W grouting for range of 3.0 times the tunnel radius, to increase stability of the tunnel we used the ling-cut method, 0.8m for one step excavation, shotcrete with 25cm thick, steel lib with H-$125{\times}125$. and a temporary shotcrete invert 20cm thick was installed to prevent deformation of the tunnel.

  • PDF

Congenital mitral valve stenosis in a Chinchilla cat

  • Lu, Ta-Li;Hung, Yong-Wei;Choi, Ran;Hyun, Changbaig
    • 대한수의학회지
    • /
    • 제56권3호
    • /
    • pp.197-200
    • /
    • 2016
  • A one-year-old, 3.25 kg intact male Chinchilla cat presented with acute right hind limb paralysis. Diagnostic imaging studies found cardiomegaly with interstitial lung pattern, abnormal mitral valve leaflets without maximum opening at the end of the ventricular diastole and during atrial systole and severe mitral inflow obstruction. Based on these findings and its young age, the case was diagnosed as congenital mitral valve stenosis. Treatment was directed to stabilize clinical conditions related to heart failure, to prevent further formation of thrombus and to relieve pain associated with thromboembolism. After one month of therapy, hind limb motor function was fully recovered.

물질흐름분석을 활용한 전세계 플라스틱 해양쓰레기의 유입량과 현존량 추정: 예비적 접근 (Estimating the Global Inflow and Stock of Plastic Marine Debris Using Material Flow Analysis: a Preliminary Approach)

  • 장용창;이종명;홍선욱;최현우;심원준;홍수연
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제18권4호
    • /
    • pp.263-273
    • /
    • 2015
  • 전세계 플라스틱 해양쓰레기의 유입량과 현존량을 추정하였다. 한국에서 플라스틱 해양쓰레기의 연간 유입량(72,956톤)은 플라스틱의 연간 소비량(5.2백만톤)의 1.4%로 추정되었다. 유출량이 0이라는 가정과 함께, 이 1.4% 유입률을 1950년부터 2013년까지 전세계 플라스틱 생산량에 적용함으로써, 2013년 전세계 연간 플라스틱 해양쓰레기 유입량은 4.2백만톤이며, 2013년말 현재 플라스틱 해양쓰레기 현존량은 86백만톤으로 추정되었다. 또한 로지스틱 모델에 따라, 석유생산량의 4%가 플라스틱으로 생산될 때 플라스틱 해양쓰레기의 최종 현존량은 199백만톤이 될 것으로 추정되었다. 유입량과 현존량은 전혀 다른 측정단위이기 때문에, 유입 저감 정책의 효과성을 평가할 수 있는 개선된 지표가 필요하다. 또한, 플라스틱 해양쓰레기 오염은 거의 회복불가능하기 때문에, 이를 예방하는 대책의 가치는 훨씬 더 높게 평가되어야 하며, 사전주의의 원칙에 따라 더 강력한 예방 대책이 시행되어야 한다. 본 연구는 제한적인 정보에 근거한 예비 연구에 해당하므로 플라스틱 해양쓰레기의 유입량과 현존량의 경향을 규명하기 위한 추가 연구가 필요하다.

Maximizing of hydropower generation of Hwacheon Reservoir using HEC-ResPRM model

  • Karimizadeh, Keivan;Choi, Changwon;Yi, Jaeeung
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.219-219
    • /
    • 2015
  • Hwacheon Reservoir is one of the reservoirs, which are located on the North Han River in South Korea. Construction of this reservoir was started in 1939 and completed in 1944. At the upstream of this reservoir there are Peace Reservoir, which is located in South Korea and Imnam Reservoir, which is located in North Korea. After construction of Imnam Reservoir, inflow regularity of Hwacheon Reservoir was changed and inflow of Hwacheon Reservoir also, was decreased. Peace Reservoir is used to decrease flood and damage at downstream due to unexpected release from Imnam Reservoir. This reservoir also, has a special role to regulate inflow of Hwacheon Reservoir. Hwacheon Reservoir has an important role for hydropower generation and flood control. Capacity and maximum discharge capacity of Hwacheon Reservoir are 1018 million $m^3$ and $9500m^3/s$, respectively. This reservoir has four generators to produce power and it is one of the important reservoirs for hydropower generation in South Korea. Due to the important role of this reservoir in generating power, maximization of hydropower generation of this reservoir is important and necessary. For this purpose, HEC-ResPRM model was applied in this study. HEC-ResPRM is a useful and applicable model to operate reservoirs and it gives optimal value for release to maximize power by minimizing penalty functions. In this study, after running the model, amount of release was optimized and hydropower generation was maximized by allocating more water for hydropower release instead of spillway release. Also, the model increased release in dry period from October to June to prevent high amount of release in flood season from July to September.

  • PDF