Analysis on the result of I/I calculation by the exiting method and the standardized maual method

하수관거 I/I(침입수/유입수) 분석방법에 따른 산정 결과 비교 -기존 보정방법과 환경부 표준 매뉴얼에 의한 방법-

  • 안병모 (과학기술연합대학원대학교) ;
  • 송호면 (과학기술연합대학원대학교)
  • Published : 2011.04.15

Abstract

The purpose of sewer system is to separate rain water from sewage water. Through this, it is possible to prevent the flood and preserve public water territory. For the past few years, many problems of the sewer system have been solved by the execution of sewer rehabilitation project. However, they still exist in sewer system caused by I/I, which are divided into infiltration and inflow. Infiltration means the rain water and underground water that infiltrate through breakage point on pipes, inflow means the water that flows in through misconnection on pipes. This study shows how the I/I calculation has changed according to the new standardized manual and identifies the I/I difference between the new calculation and the existing one. Through the analysis on the two calculation methods we examined the appropriacy of the new method by comparing it to the old one. The result points out that the new standardized manual is more appropriate than the old in aspect of objectivity and reproducibility(establish standardization), rationality(alteration of inflow unit).

Keywords

References

  1. 서원석 (2009) 분류식 하수도 침입수/유입수 발생특성 분석, 석사학위논문, 한양대학교
  2. 송호면, 조정일, 안충희 (2010) 하수관거정비 BTL사업의 효과분석 및 방안 수립 연구, 대한상하수도학회지, 24(6), pp.743-751
  3. 장대환, 한인섭, 우병하, 홍성진 (2009) 하수관거내 불량개소수와 I/I발생량간의 상관성분석, 대한상하수도학회지, 23(3), pp.321-329
  4. 왕주용 (2010) 하수관거 침입수 및 유입수 산정 표준지침에 따른 불명수량 산정 및 적용에 대한 연구, 석사학위논문, 중앙대학교
  5. 환경부(2010) 공공하수처리시설 운영관리실태 분석결과
  6. 환경부(2009) 하수관거 침입수 및 유입수 산정 표준 매뉴얼
  7. 환경부(2010) 하수도 통계연보
  8. Antonio Jorge Monteiro, Ana Teresa Silva (2009) Integrated strategies for the reduction of infiltration and inflow in sanitary sewer systems, Water Asset Management International, IWA Publishing
  9. O. Raynaud, C. Joannis, F. Schoefs, F. Billard (2008) A model-based assessment of infiltration and inflow in the scope of controlling separate sanitary overflows at pumping stations, 11th International Conference on Urban Drainage