• Title/Summary/Keyword: PR 제거

Search Result 62, Processing Time 0.026 seconds

Study of Supercritical Carbon Dioxide/n-Butyl Acetate Co-solvent System with High Selectivity in Photoresist Removal Process (포토레지스트 공정에서 높은 선택성을 가지는 초임계 이산화탄소/n-butyl acetate 공용매 시스템 연구)

  • Kim, Dong Woo;Heo, Hoon;Lim, Kwon Teak
    • Clean Technology
    • /
    • v.23 no.4
    • /
    • pp.357-363
    • /
    • 2017
  • In this study, the supercritical carbon dioxide ($scCO_2$)/ n-butyl acetate (n-BA) co-solvent system was employed to remove an unexposed negative photoresist (PR) from the surface of a silicon wafer. In addition, the selectivity of the $scCO_2$/n-BA co-solvent system was confirmed for the unexposed and exposed negative PR. Optimum conditions for removal of the unexposed PR were obtained from various conditions such as pressure, temperature and n-BA ratio. The n-BA was highly soluble in $scCO_2$ without cloud point and phase separation in mostly experimental conditions. However, the $scCO_2$/n-BA co-solvent was phase separated at 100 bar, above $80^{\circ}C$. The unexposed and exposed PR was swelled in $scCO_2$ solvent at all experimental conditions. The complete removal of unexposed PR was achieved from the reaction condition of 160 bar, 10 min, $40^{\circ}C$ and 75 wt% n-BA in $scCO_2$, as measured by ellipsometry. The exposed photoresist showed high stability in the $scCO_2$/n-BA co-solvent system, which indicated that the $scCO_2$/n-BA co-solvent system has high selectivity for the PR removal in photo lithograph process. The $scCO_2$/n-BA co-solvent system not only prevent swelling of exposed PR, but also provide efficient and powful performance to removal unexposed PR.

A Study on the High Efficiency PR Strip technology by using the Ozone Process (오존공정을 이용한 고효율 PR 제거기술 연구)

  • Son, Young-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.1
    • /
    • pp.22-27
    • /
    • 2007
  • we have been studied on the realization of the boundary layer controlled ozone process and related facilities in order to apply for the photo-resist strip process in the semiconductor and flat panel display manufacturing. By means of developing the technology for the high concentration ozone production, it was possible to realized the boundary layer control ozone process by vapor. As a result of the silicon wafer PR strip test, we obtained the strip rate of about 400nm/min at the ozone concentration of 16wt% and flow rate of 8[liter/min.].

Efficient Stripping of High-dose Ion-implanted Photoresist in Supercritical Carbon Dioxide (초임계 이산화탄소를 이용한 고농도이온주입 포토레지스트의 효율적인 제거)

  • Kim, Do-Hoon;Lim, Eu-Sang;Lim, Kwon-Taek
    • Clean Technology
    • /
    • v.17 no.4
    • /
    • pp.300-305
    • /
    • 2011
  • A mixture of supercritical carbon dioxide and a co-solvent was employed to strip a high-dose ion-implanted photoresist (HDIPR) from the surface of semiconductor wafers. The stripping efficiency was highly improved by the physical force generated from a ultrasonication tip inside the reactor. In addition, helium gas was injected in the reactor as a barrier gas before the introduction of pure supercritical $CO_2$ ($scCO_2$), which reduced the rinsing time significantly. The effect of co-solvents on the stripping efficiency was investigated. The wafer surfaces were analyzed by scanning electron microscopy and by an energy dispersive X-ray spectrometer.

Photoresist strip 성능 향상을 위한 플라즈마 약액 활성화 방법 연구

  • Kim, Su-In;Lee, Chang-U
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.242-242
    • /
    • 2008
  • 반도체 공정에서 일정한 패턴을 만들기 위하여 Photoresist (PR)를 이용한 식각 공정을 사용하게 된다. 이러한 식각 공정은 반도체 직접도가 증가되면서 더욱 많은 단계의 공정을 요구하게 되었다. 그러나 식각 공정의 증가는 반도체 소자 생산을 위한 더 많은 시간과 비용을 요구하게 된다. 이를 해결하기 위하여 Photoresist를 사용하지 않은 공정으로 공정 단계를 간소화하기 위한 연구를 진행하고 있지만 아직 명확한 대한은 없다. 본 연구에서 는 PR의 strip 시간을 최대한 단축시키고 PR strip 잔여물의 빠른 제거를 위하여 기존 공정에서 사용 중인 strip 약 액을 플라즈마에 의하여 활성화하는 방법으로 PR strip 시간을 최대한 줄이는 방법에 대한 연구를 진행하였으며, 활성화된 strip용액이 더욱 빠른 strip율을 나타내는 것을 확인하였다. 또한 약액 활성화 방법으로 활성화된 strip 용액으로 PR을 일부 제거한 후 PR 표면의 물리적 특성 변화를 분석하여 약액 활성화된 strip 용액으로 인한 PR의 특성을 물리적 방법으로 접근하여 연구를 진행하였다.

  • PDF

UV/ozone Cleaning Processes for Organic Films on Si Studied by in-line XPS and AFM (in-line XPS와 AFM을 이용한 유기물의 UV/ozone 건식세정과정 연구)

  • 이경우;황병철;손동수;천희곤;김경중;문대원;안강호
    • Journal of the Korean Vacuum Society
    • /
    • v.4 no.3
    • /
    • pp.261-269
    • /
    • 1995
  • 본 실험에서는 실리콘 웨이퍼 위에 photoresist(PR)와 octadecyltrichlorosilane(OST, CH3((CH2)17SiCI3)를 입혀서 UV/zone 처리를 어떻게 유기물질들이 UV/zone과 반응하여, 어떻게 표면에서 제거되는지를 in-line으로 연결된 XPS로 분석하고 반응시킨 표면들의 거칠기(roughness)를 AFM을 이용하여 관찰하였다. 실험결과 상온에서 UV/zone 처리를 했을 경우, PR과 OTS같은 유기물질이 표면에서 산화되는 것을 알 수 있었으나 이들이 제거되지 않고 표면에 그대로 남아있음을 알 수 있었다. 그러나 가열하면서(PR:$250^{\circ}C$, ORS:$100^{\circ}C$)UV/ozone 처리를 하였을 경우 표면에서 산화됨과 동시에 이들 산화물들이 표면에서 제거됨을 알 수 있었다. XPS 분석으로부터 이들의 산화반응물은 PR과 OTS 모두 -CH2-, -CH2O-, =C=O, -COO-를 가지는 것으로 나타났으며, 열에너지에 의해서 이들이 표면에서 제거되는 것으로 나타났다. AFM 분석결과는 상온에서 UV/ozone 처리를 하였을 경우에 표면의 거칠기가 적은 반면, 가열하면서 UV/o-zone처리를 하였을 경우에는 표면의 거칠기가 다소 증가하였다.

  • PDF

Improvement of PR Stripper Efficient and Change of Surface Hardness for HDI-PR Used by PLVA Method (PLVA 방법을 활용한 PR Stripper의 성능 향상과 HDI-PR 표면의 내력 변화 연구)

  • Kim, Soo-In;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.544-548
    • /
    • 2008
  • At the semiconductor industry, Photoresist(PR) strip progress has high cost and time consuming process. Accordingly, many research group have been focused on the shortening of the PR strip progress. But the replacements of newly developed materials rather than normally used strip have accompanied by cost consumption. Therefore, we suggested the Plasma Liquid-Vapor Activation (PLVA) method of general PR strip solution for saving the PR strip time and the high strip rate of PR residue. The PLVA method was very effective for PR strip progress. Also, the ion damaged PR(high dose implanted photoresist: HDI-PR) was almost impossible to strip. However, it was very difficult to characterize the change of chemical composition of HDI-PR between with and without PLVA method. Thus, physical properties of HDI-PR surface with and without PLVA method were measured by using the nano-indenter system.

A Study on the Ozonized Water Production technology for the PR Strip Process (PR 제거공정 적용을 위한 오존 수 생성기술 연구)

  • Son Young Su;Chai Sang Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.12
    • /
    • pp.13-19
    • /
    • 2004
  • We have been studied on the high concentration ozonized water production technology which substitute for the SPM wet cleaning solution process as the PR strip process after the photolithography process in the semiconductor and flat panel display manufacturing. In this work, we have developed the surface discharge type ozone generator which has the characteristics of the 12 [wt%] ozone concentration at the oxygen gas flow of 0.5[ℓ/min] oxygen per cell and also developed the high efficiency ozone contactor for the mixing ozone gas with deionized water. As the production test results of the ozonized water, we obtained the ozonized water concentration above 80[ppm] at the 10[wt%] ozone gas concentration, and also had a good result of the PR strip rate of 147[nm/min]. at the 70[ppm] ozonized water.

Activation of Stripper Solution by Plasma and Hardness/Modulus of Elasticity Change of the Surface (Plasma를 이용한 세정액의 활성화와 시료 표면의 탄성계수 및 강도 변화에 대한 연구)

  • Kim, Soo-In;Kim, Hyun-Woo;Noh, Seong-Cheol;Yoon, Duk-Jin;Chang, Hong-Jun;Lee, Jong-Rim;Lee, Chang-Woo
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.2
    • /
    • pp.97-101
    • /
    • 2009
  • In the modem semiconductor industry, the progress that consumes the most capital and labor is cleansing process. Cleansing process is to remove impurities that can affect the operation of the device and deteriorate its function. Especially, Photoresist (PR) progress that etches the device always requires cleansing at the end of the progress. Also, HDI-PR (High-Dose Ion-implanted Photoresist) created from PR progress is difficult to remove. Thus, in modem IC cleansing, many steps of cleansing are used, including dry and wet cleansing. In this paper, we suggested to combine existing dry-cleansing and wet-cleansing, each represented by plasma cleansing and stripper solution, as Plasma Liquid-Vapor Activation (PLVA). This PLVA method enhances the effect of existing cleansing solution, and decreases the amount of solution and time required to strip. We stripped HDI-PR by activated solution and measured surface hardness and Young's modulus by Nano-indenter. Nano-indenter is the equipment that determines the hardness and the modulus of elasticity by indenting nano-sized tip with specific shape into the surface and measuring weight and z-axis displacement. We measured the change of surface hardness and Young's modulus before and after the cleansing. As a result, we found out that the surface hardness of the sample sharply decreased after the cleansing by plasma-activated PR stripper solution. It can be considered that if physical surface-cleansing process is inserted after this, more effective elimination of HDI-PR is possible.

Study on selective PR removal at Color filter process (Color Filter Process에서 선택적 Photoresist 제거방안에 대한 연구)

  • Lee, Sang-Eon;Park, Jung-Dae;Huh, Dong-Chul;Hah, Steve;Lee, Sun-Yong;Roh, Yong-Han
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.95-96
    • /
    • 2006
  • CMOS Image Sensor(CIS) 소자에서 광감도의 향상과 천연색 형성을 위하여 적용하고 있는 Color-Filter 공정에서 국부적으로 발생하는 strip성 불량과 막질손상을 제거하기 위한 연구를 진행하였다. 우선 지역적 경향성을 보이는 불량에 대해서는 PR strip process type을 액조 진행방식에서 회전식으로 변경했을 때 제거됨을 확인하였고, 막질손상을 최소화하기 위해서는 새로운 유기용매의 적용이 필요하였다. 실험 결과, 케톤기를 가지는 화합물과 Polar Apotic 용매의 혼합화합물을 적용하였을 때 각 막질에 attack을 최소화하면서 원하는 PR만 선택적으로 제거 되며 미세잔류성분에 대한 제거력도 향상됨을 확인하였다.

  • PDF

A Study on the corrosion property by post treatment in the metal dry etch (Metal 건식각 후처리에 따른 부식 특성에 관한 연구)

  • Mun, Seong-Yeol;Kang, Seong-Jun;Joung, Yang-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2007.10a
    • /
    • pp.747-750
    • /
    • 2007
  • This study proposes that chlorine residue after metal etch as the source of metal corrosion, and charges should be removed by optimizing etch, PR strip and cleaning condition. Charges distributed along the metal line acts as a source of tungsten (W) plug corrosion when associated with following cleaning solution. In cleaning process after metal etch and PR strip, chemical selection is significantly important in terms of metal corrosion. Optimal corrosion preventive PH, no metal attack (choice of optimal inhibitants), high by product removal efficiency and optimal de ionized water treatment condition is critical to the metal corrosion prevention.

  • PDF