• Title/Summary/Keyword: POLYDIMETHYLSILOXANE

Search Result 373, Processing Time 0.026 seconds

Fabrication of Micro Component of Metallic Nano Powder Using Polymer Mold (폴리머 몰드를 이용한 금속 나노분말의 미세부품 제조)

  • Lee, Woo-Seok;Kim, Sang-Phil;Lee, Hye-Moon;Bae, Dong-Sik;Choi, Chul-Jin
    • Journal of Powder Materials
    • /
    • v.14 no.3 s.62
    • /
    • pp.202-207
    • /
    • 2007
  • Novel polymer mold process for fabrication of microcomponents using metal nanopowders was developed and experimentally optimized. Polymer mold for forming green components was produced by using a hard master mold and polydimethylsiloxane (PDMS). In the preparation of metallic powder premix for the green components without any defect, 90 wt.% 17-4PH statinless steel nanopowders and 10 wt.% organic binder were mixed by a ball milling process. The green components with very clear gear shape were formed by filling the powder premix into the PDMS soft mold in surrounding at about $100^{\circ}C$. Cold isostatic pressing (CIP) was very potent process to decrease a porosity in the sintered microcomponent. The microgear fabricated by the improved process showed a good dimension tolerance of about 1.2%.

Rapid and Simultaneous Determination of Volatile Fatty Acids and Indoles in Pig Slurry and Dog Excrement by Solid-Phase Micro-Extraction Method with Gas Chromatography

  • Kim, Hyun-Jung;Yu, Mee-Seon;Yang, Sung-Bong
    • Journal of Environmental Science International
    • /
    • v.23 no.10
    • /
    • pp.1693-1701
    • /
    • 2014
  • A rapid and simple method for the quantitative determination of volatile fatty acids (VFAs; propionic acid, n-butyric acid, i-valeric acid and n-valeric acid) and indoles (phenol, p-cresol, 4-ethyl phenol, indole and skatole) in pig slurry and dog excrement using solid-phase micro-extraction (SPME) coupled to gas chromatography was evaluated. $50/30{\mu}m$ DVB/CAR/PDMS (Divinylbenzene/Carboxen/Polydimethylsiloxane) fiber was used to extract the target compounds in aqueous media. Sample amount and adsorption time was standardized for the routine analysis. Detection limits were from 0.11 to $0.15{\mu}gL$ for VFAs and from 0.12 to $0.28{\mu}gL$ for indoles and the correlations observed ($R^2$) were 0.975~1.000. This method was applied to the pig slurry, fertilizer, compost and dog excrement. In nearly all cases, the indoles were detected in concentrations of higher than their limits of detection (DOLs). But the VFAs in swine manure were below their DOLs.

Fabrication of ZnO TFTs by micro-contact printing of silver ink electrodes

  • Shin, Hong-Sik;Yun, Ho-Jin;Nam, Dong-Ho;Choi, Kwang-Il;Baek, Kyu-Ha;Park, Kun-Sik;Do, Lee-Mi;Lee, Hi-Deok;Wang, Jin-Suk;Lee, Ga-Won
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1600-1603
    • /
    • 2009
  • In this work, we have fabricated inverted staggered ZnO TFTs with 1-${\mu}m$ resolution channel length by micro contact printing (${\mu}$-CP) method. Patterning of micro scale source/drain electrodes without etching is successfully achieved by micro contact printing method by using silver ink and polydimethylsiloxane (PDMS) stamp. And the time dependent characteristics of the sheet resistance show that Ag inklayer could be used as source and drain electrodes for ZnO TFTs.

  • PDF

Fabrications and Characteristics of Microfluidic Systems Actuated by Thermopneumatic Method (열공압 방식으로 구동되는 매세 유체 제어 시스템의 제작 및 특성)

  • Yoo Jong-Chul;Kang C. J.;Kim Yong-Sang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.88-92
    • /
    • 2006
  • We present a microfluidic system with microvalves and a micropump that are easily integrated on the same substrate using the same fabrication process. The fabricated microfluidic system is suitable for use as a disposable device and its characteristics are optimized for use as a micro chemical analysis system (micro-TAS) and lab-on-a-chip. The system is realized by means of a polydimethylsiloxane (PDMS)-glass chip and an indium tin oxide (ITO) heater. We demonstrate the integration of the micropump and microvalves using a new thermopneumatic-actuated PDMS-based microfluidic system. A maximum pumping rate of about 730 nl/min is observed at. a duty ratio of 1 $\%$ and a frequency of 2 Hz with a fixed power of 500 mW. The measured power at flow cut-off is 500 mW for the microvalve whose channel width, depth and membrane thickness were 400 $\mu$m, 110 $\mu$m, and 320 $\mu$m, respectively.

Fabrication and Evaluation of the Flexible and Implantable Micro Electrode (생체 삽입형 유연한 마이크로 전극의 제작 및 평가)

  • Baek Ju-Yeoul;Kwon Gu-Han;Lee Sang-Woon;Lee Ky-Am;Lee Sang-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.2
    • /
    • pp.93-99
    • /
    • 2006
  • In this paper, we fabricated and evaluated polydimethylsiloxane(PDMS)-based flexible and implantable micro electrodes. The electrode patterning was carried out with the photolithography and chemical etching process after e-beam evaporation of 100 ATi and 1000 A Au. The PDMS substrate was treated by oxygen plasma using reactive ion etching(RIE) system to improve the adhesiveness of PDMS and metal layers. The minimum line width of fabricated micro electrode was 20 $\mu$m. After finished patterning, we did packaging with PDMS and then brought up the electrode's part about 40 $\mu$m with gold electroplating. The Hank's balanced salt solution(HBSS) test was carried out for 6 month for endurance of fabricated micro electrode. We carried out in-vivo test for the evaluation of biocompatibility by implanting electrodes under the ICR mouse skin for 42 days.

Mixing Efficiency Evaluation in Y-channel Micromixer Using LIF Confocal Microscope (LIF 공초점 현미경을 이용한 Y-채널 마이크로믹서의 혼합 효율 평가)

  • Kim, Kyoung-Mok;Shin, Yong-Su;Ahn, Yoo-Min;Lee, Do-Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.159-166
    • /
    • 2007
  • Mixing between two or more reagents is one of important processes in biochemical microfluidics. In efficient micromixer design, it is essential to analyze flow pattern and evaluate mixing efficiency with good precision. In this work, mixing efficiency for Y-channel micromixer is measured by fluorescence intensity using LIF(Laser Induced Fluorescence) Confocal Microscope. The Y-channel micromixers are fabricated with polydimethylsiloxane(PDMS) and those are bonded to glass plate through Plasma bonding. Nile Blue A is injected into the micromixer as a fluorescence dye for measuring of fluorescence intensity by He/Ne laser. For visualization of the flow pattern, dynamic image capturing is carried out using CAM scope. For the comparison with computer simulation, modified SIMPLE algorithm for incompressible flow equation is solved for the same geometry as in the experiment. Throughout the experiments and computer simulation, accurate mixing efficiency evaluation process for a PDMS Y-channel micromixer is established.

Fabrication and application of a microcantilever biosensor for a protein detection (단백질 검출을 위한 mirocantilever 바이오센서의 제작과 응용)

  • Kim, Jun-Hyuk;Yoo, Kyung-Ah;Joung, Seung-Ryong;Kim, Han-Soo;Kim, Jae-Wan;Choi, Y.J.;Kang, C.J.;Kim, Yong-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1647-1648
    • /
    • 2006
  • 화학적, 생물학적 분석, 즉 특정 물질의 존재 유무를 측정하기 위해 마이크로캔틸레버라는 구조체를 제작하여 이를 바이오센서로 응용하였다. 마이크로캔틸레버의 장점은 분석하고자 하는 시료의 양이 적더라도 감지가 가능하고 이를 통하여 분석시간을 단축할 수 있다는 장점을 가지고 있다. 마이크로캔틸레버 구조물 제작을 위해 보편적으로 많이 이용되는 bulk 미세 가공 기술을 대신하여 표면 미세 가공기술을 이용하였다. 이러한 표면 미세 가공기술은 bulk 미세 가공기술에 비해 공정이 간단하고 값이 싸다는 장점이 있다. 또 액상 실험을 위하여 polydimethylsiloxane (PDMS)와 fused silica glass를 사용한 유체 제어 시스템을 제작하였다. 본 연구에서는 자기조림 이라는 특성을 이용하여 생물분자를 유체 제어 시스템 내의 마이크로캔틸레버 상단에 immobilization 시킨 후 마이크로캔틸레버 상, 하단의 표면 스트레스 차이에 따른 마이크로캔틸레버 자체의 휘어지는 정도를 측정하였다. 이러한 휘어지는 현상을 관찰함으로서 마이크로캔틸레버의 바이오센서로 응용 가능성을 확인한 수 있었다.

  • PDF

Effect of PDMS Index Matching Layer on Characteristics of Mn-Doped SnO2 (MTO)/Ag/MTO/PDMS/MTO Transparent Electrode (PDMS 굴절 조정층이 Mn-Doped SnO2 (MTO)/Ag/MTO/PDMS/MTO 투명전극의 특성에 미치는 영향)

  • Jo, Young-Su;Jang, Gun-Eik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.408-411
    • /
    • 2018
  • We fabricated highly flexible Mn-doped $SnO_2$ (MTO)/Ag/MTO/polydimethylsiloxane (PDMS)/MTO multilayer transparent conducting films. To reduce refractive-index mismatching of the MTO/Ag/MTO/polyethylene terephthalate (PET), index-matching layers were inserted between the oxide-metal-oxide-structured films and the PET substrate. The PDMS layer was deposited by spin-coating after adjusting the mixing ratio of PDMS and hexane. We investigated the effects of the index-matching layer on the color and reflectance differences with different PDMS dilution ratios. As the dilution ratio increased from 1:100 to 1:130, the color difference increased slightly, while the reflectance difference decreased from 0.62 to 0.32. The MTO/Ag/MTO/PDMS/MTO film showed a transmittance of 87.18~87.68% at 550 nm. The highest value of the Haacke figure of merit was $47.54{\times}10^{-3}{\Omega}^{-1}$ for the dilution ratio of 1:130.

Development of Stretchable PZT/PDMS Nanocomposite Film with CNT Electrode

  • Yun, Ji Sun;Jeong, Young Hun;Nam, Joong-Hee;Cho, Jeong-Ho;Paik, Jong-Hoo
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.400-403
    • /
    • 2013
  • The piezoelectric composite film of ferroelectric PZT ceramic ($PbZr_xTi_{1-x}O_3$) and polymer (PDMS, Polydimethylsiloxane) was prepared to improve the flexibility of piezoelectric material. The bar coating method was applied to fabricate flexible nanocomposite film with large surface area by low cost process. In the case of using metal electrode on the composite film, although there is no problem by bending process, the electrode is usually broken away from the film by stretching process. However, the well-attached, flexible CNT electrode on PZT/PDMS film improved flexibility, especially stretchability. PZT particles was usually settled down into polymer matrix due to gravity of the weighty particle, so to improve the dispersion of PZT powder in polymer matrix, small amount of additives (CNT powder, Carbon nanotube powder) was physically mixed with the matrix. By stretching the film, an output voltage of PZT(70 wt%)/PDMS with CNT (0.5 wt%) was measured.

A Study on the Microfabricated Clark-type Sensor for Measuring Dissolved Oxygen (용존 산소 측정용 초소형 Clark-type 센서에 대한 연구)

  • Park, Jung-Il;Chang, Jong-Hyeon;Choi, Myung-Ki;Lee, Dong-Young;Kim, Young-Mi;Pak, Jung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.8
    • /
    • pp.1450-1454
    • /
    • 2007
  • This paper presents a microfabricated Clark-type sensor which exactly can measure dissolved oxygen in the cell containing solution. We designed, fabricated, and characterized a microfabircated Clark-type oxygen sensor for measuring dissolved oxygen. The microfabricated oxygen sensor consists of 3-electrodes on a glass substrate, a FEP (Fluorinated ethylene propylene) oxygen-permeable membrane, and PDMS (Polydimethylsiloxane) reservoir for storing sample solution. Thin-film Ag/AgCl was employed as a reference electrode and its durability was verified by obtaining a stable open circuit potential for 2 hours against a commercial Ag/AgCl electrode and a stable cyclic voltammetry curve. Selectivity, response time, and linearity of the fabricated oxygen sensor were also verified well by cyclic voltammetry and amperometry depending. The fabricated oxygen sensor showed a 90% response time of 40sec and an excellent linearity with a correlation coefficient of 0.994.