A Study on the Microfabricated Clark-type Sensor for Measuring Dissolved Oxygen
![]() ![]() |
Park, Jung-Il
(고려대 공대 대학원 전기공학과)
Chang, Jong-Hyeon (고려대 공대 대학원 전기공학과) Choi, Myung-Ki (고려대 공대 대학원 전기공학과) Lee, Dong-Young (울산대 의대 아산생명과학연구소) Kim, Young-Mi (울산대 의대 아산생명과학연구소) Pak, Jung-Ho (고려대 공대 전기전자전파공학부) |
1 | L. C. Clark, 'Electrochemical device for chemical analysis,' US patent 2,913,386, 1956 |
2 | H. Suzuki, A. Sugama, and N. Kojima, 'Micromachined Clark oxygen electrode,' Sensors and Actuators B, vol. 10, pp. 91-98, 1993 DOI ScienceOn |
3 |
H. Suzuki, T. Hirakawa, S. Sasaki, and I. Karube, 'An integrated module for sensing |
4 | H. Suzuki, H. Ozawa, S. Sasaki, and I. Karube, 'A novel thin -film Ag/AgCI anode structure for microfabricated Clark-type oxygen electrode,' Sensors and Actuators B, vol. 53, pp. 140-146, 1998 DOI ScienceOn |
5 | W. Glasspool and J. Atkinson, 'A screen-printed amperometric dissolved oxygen sensor utilising an immobilised electrolyte gel and membrane,' Sensros and Actuators B, vol. 48, pp. 308-317, 1998 DOI ScienceOn |
6 | H. Suzuki, A. Hiratsuka, S. Sasaki, and I. Karube, 'Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durability,' Sensors and Actuators B, vol. 46, pp. 104-113, 1998 DOI ScienceOn |
7 | C.-C. Wu, T. Yasukawa, H. Shiku, and T. Matsue, 'Fabrication of miniature Clark oxygen sensor integrated with microstructure,' Sensors and Actuators B, vol. 110, pp. 342-349, 2005 DOI ScienceOn |
8 | G. W. McLaughlin, K. Braden, B. Franc, G. T. A. Kovacs, 'Microfabricated solid-state dissolved oxygen sensor,' Sensors and Actuators B, vol. 83, pp. 138-148, 2002 DOI ScienceOn |
9 | J.-H. Lee and T.-J. Kim, 'A study on oxygen permeability of polypropylene membranes and their temperature dependency using medical oxygen sensor,' Korean Journal Biotechnology and Bioengineering, vol. 19, pp. 62-64, 2004 과학기술학회마을 |
10 | T.-J. Kim, T.-H. Jurng, D.-H. Chung, and S.-I Hong, 'Simultaneous determination of oxygen transport characteristics of six membranes by hexagonal dissolved oxygen sensor systems,' Sensors and Actuators B, vol. 72, pp. 11-20, 2001 DOI ScienceOn |
11 |
H. Suzuki, T. Hirakawa, I. Watanabe, and Y. Kikuchi, 'Determination of blood |
12 | B. B. Lowell and G. I. Schulman, 'Mitochondrial dysfunction and type 2 diabetes,' Science, vol. 307, pp. 384-387, 2005 DOI ScienceOn |
13 |
W. Wang, H. Suzuki, K. Hayashi, T. Kaneko, and K. Sunagawa, 'Microfabricated needle-type sensors for |
14 |
S. Kojima, M. oughran, and H. Suzuki, 'Microanalysis system for |
15 | M. Wittkampf, G.-C. Chemnitius, K. Cammann, M. Rospert, and W. Mokwa, 'Silicon thin film sensor for measurement of dissolved oxygen,' Sensors and Actuators B, vol. 43, pp. 40-44, 1997 DOI ScienceOn |
16 | H. K. Lee, Y. M. Cho, Y. Y. Lee, and Y. K. Pak, 'Mitochondria-based model for fetal origin of adult disease and insulin resistance,' Ann. N. Y. Acad. Sci., vol. 1042, pp. 1 - 18, 2005 DOI |
17 | X. Sun and M. Wang, 'Fabrication and characterization of planar reference electrode for on-chip electroanalysis,' Electrochimica Acta, vol. 52, pp. 427-433, 2006 DOI ScienceOn |
![]() |