• Title/Summary/Keyword: PLC modem

Search Result 70, Processing Time 0.043 seconds

Implementation of PLC modem using DS/SS for Automation (자동화를 위한 DS/SS 방식의 전력선 모뎀 구현)

  • 박준용;최원호;노경호;박종연
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.493-496
    • /
    • 2003
  • This paper studied the method to improve the reliability with the simple structure and the decreased calculation of Micro-Controller(uC) in Power Line Modem. We have implementation the program which correct the 1-bit error of the $\mu$C within the control system and the DS/SS(Direct sequence/spread spectrum) by adding the simple circuit between a single chip powerline transceiver IC and a uC.

  • PDF

A Study on Broadband PLC for Power IT (전력IT를 위한 광대역 전력선통신에 관한 연구)

  • Kim, Yeoun-Soo;Shin, Jae-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.8
    • /
    • pp.1599-1605
    • /
    • 2011
  • From now on, power line communication was made use of controling using 450 kHz narrow band, but as the PLC technology developing, in the near future get to the commercial step that is broadband PLC upto 30 MHz. In this paper, analyze the possibility of moving picture transmission for adapting surveillance camera which is among of the application of PLC. To analyze characteristics of channel, estimate the noise and impedance of lab, office, home. In case of noise, there is no problem to communicate each other because of 20 ~ 50 dB gain. In case of impedance, average impedance is about 100 ohm, it satisfy standards of designing modem but because max and min values get out of expectation there are some problem to acquire fully capacity of modems. Its condition is the same as transmission of multimedia data. In this test as more packets, as more handling rate, in lab, for the case that transmit 1,518 byte as the speed of 6 Mbps handling rate is upto 100%, it means possibility of moving picture transmission as the 6 Mbps speed. For delayed time there is no relationship about transmitted packets. As a result, there is no problem about applying surveillance camera via the PLC. And more cameras can work within PLC for considering the number of transmitted frames.

Zigbee & PLC Integrated Gateway Development for U-Health Care Environment and Intelligent Home Network (유비쿼터스 헬스케어 환경 및 지능형 홈 네트워크를 위한 Zigbee & PLC 통합 게이트웨이 개발)

  • Son, Hui-Bae;Kim, Sung-Yun;Rhee, Young-Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.2 no.4
    • /
    • pp.73-80
    • /
    • 2009
  • In this paper, we implemented the integrated gateway for health care and home network system based on PLC(Power Line Communication) and Zigbee. The designed system is consists of sensors, integrated gateway, Zigbee module and PLC modem. The integrated gateway will transmit the data which is collected by health care sensors to health care control system and control an appliance for comfortable environment to medical facilities. The implemented gateway can support various health care and home network service.

  • PDF

Study on Network Throughput of Power Line Communication System in In-Building Network (전력선 통신 시스템의 구내 네트워크 데이터 처리량 연구)

  • Jang, Ho-Deok
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.43-47
    • /
    • 2021
  • This paper investigates the network throughput of PLC (Power Line Communication) system in the in-building network. The OFDM (Orthogonal Frequency Division Multiplexing) modulation format and adaptive bit loading algorithm is used to minimize the effect of signal loss and noise on transmission performance in the power line channel characterized by frequency selective fading. The network throughput of the PLC system which consists of gateway and CPE(Customer Premise Equipment) PLC modem in the in-building network is measured by network performance measurement tool, iperf and analyzed according to the TCP (Transmission Control Protocol) window size.

A study on the improvement of impedance decline in PLC (PLC에서의 임피던스 저하 개선에 관한 연구)

  • Choi, Tae-Seop;Ahn, In-Soo
    • Journal of the Institute of Electronics Engineers of Korea TE
    • /
    • v.42 no.3
    • /
    • pp.7-12
    • /
    • 2005
  • In this paper, we used class D amplification circuit to improve the decline of error rate caused by low impedance in the Power Line Communication. We manufactured voltage drive circuit and current drive circuit that are driven circuit of power line modem on the present and made a comparison experiment with drivel circuit that uses class D amplifier proposed in this paper. As a result of Experiment, We showed that it has great superiority over other existing drive circuits at rapid impedance change in power line channel.

Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication (전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현)

  • Son, Do-Sun;Kim, Ki-Hyun;Kim, Sang-Cheol;Jeon, Eui-Seok;Lee, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1947-1948
    • /
    • 2008
  • This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

  • PDF

Implementation of dimming system using FH/SS Power Line Communication modem (FH방식의 전력선 모뎀에 의한 집단 조광제어 시스템 구현)

  • Choi Won-ho;Park Jun-yong;No Kyoung-ho;Park Chong-yeon
    • Proceedings of the KIPE Conference
    • /
    • 2004.07a
    • /
    • pp.163-166
    • /
    • 2004
  • The conventional fluorescent lamp dimming system using an another control line is complex and will increased the cost. Therefore, many studies have focused on the wireless communication, but it is not fit for dimming system because of the interference generated by the infra-red light of lamp or switching noises in ballast. So, we applied the power line communication on the dimming system and we proposed a new coupling circuit using the voltage controlled impedance convertor for improving the performance of the FH/SS PLC modem. The performance for the proposed modem is evaluted by the BER.

  • PDF

A study on the Drive Circuit Design in the Power Line Communication (PLC에서의 구동회로설계에 관한 연구)

  • Choi, Tae-Seop;Lim, Seung-Ha
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.1301-1304
    • /
    • 2005
  • In this paper, we used class D amplification circuit proposed to improve the decline of error rate caused by rapidly variable impedance in the Power Line Communication. We manufactured voltage drive circuit and current drive circuit that are driven circuit of power line modem on the present. And with the same power line modem, we made a comparison experiment applying the driver circuit that used class D amplifier proposed in this paper. As a result of Experiment, We showed that it has more superior than other existing drive circuits at the impedance change in the power line communication.

  • PDF

A study of the light control system for the MH lamp using the power line communication (전력선 통신을 이용한 MH 램프의 조광제어 시스템에 관한 연구)

  • Jung, Kwang-Hyun;Park, Chong-Yeun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.2
    • /
    • pp.83-91
    • /
    • 2008
  • To design the light control system using the PLC(Power Line Communication) with the ballasts of MH(Metal Halide) lamps, we analyzed the noise effect on the power line by the electronic ballast. For the power line characteristics are changed by the loads, the ballast have to be designed to be suitable to the PLC. Therefore, this paper proposed the optimal ballast and designed two kinds of PLM(Power Line Modem) which one is ASK type and the other is FSK type. Two type of PLM have used the manchester codes or DS/SS code. Experimental results have shown that the FSK type modem by the DS/SS coding technique have the best characteristics.