Method and implementation for reducing standby power consumption in intermediate capacity power supply with Power Line Communication

전력선통신기능 적용 중.대용량 전원공급장치의 대기전력 절감방법 및 구현

  • Published : 2008.07.16

Abstract

This paper presents the implementation of Power Line Communication(PLC) module which can reduce standby-power consumption. The suggested PLC module consists of PLC modem, coupling circuit, ZCP(Zero-Cross Point) Circuit and main SMPS control relay. The test results under power line communication test-bed used home appliance show the 77% saving of standby-power.

Keywords