• 제목/요약/키워드: PHC-pile

검색결과 176건 처리시간 0.02초

대구경 PHC말뚝 및 대구경 복합말뚝($\phi$1,000mm) 지지력 산정에 관한 연구 (Bearing capacity of large diameter PHC pile and large diameter composite pile)

  • 신윤섭;박재현;황의성;조성한;정문경;이진영
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 춘계 학술발표회
    • /
    • pp.351-359
    • /
    • 2010
  • Large PHC piles with a diameter of 1,000mm or larger were recently introduced for the first time in Korea. This paper presents full-scale static and dynamic pile load tests performed on two 1,000mm PHC piles and two composite piles with steel pipe piles of the same diameter in the upper portion, installed by driving and pre-boring. The objectives of the tests include evaluating pile drivability, load-settlement relation, allowable bearing capacity, and the stability of mechanical splicing element for the composite pile(a.k.a. non-welding joint). The performance of the large diameter PHC piles were thought to be satisfactory compared to that of middle sized PHC piles with a long history of successful applications in the domestic and foreign markets.

  • PDF

Effects of infilled concrete and longitudinal rebar on flexural performance of composite PHC pile

  • Bang, Jin Wook;Lee, Bang Yeon;Lee, Byung Jae;Hyun, Jung Hwan;Kim, Yun Yong
    • Structural Engineering and Mechanics
    • /
    • 제52권4호
    • /
    • pp.843-855
    • /
    • 2014
  • Concrete infill and reinforcement are one of the most well-known strengthening methods of structural elements. This study investigated flexural performance of concrete infill composite PHC pile (ICP pile) reinforced by infill concrete and longitudinal rebars in hollow PHC pile. A total four series of pile specimens were tested by four points bending method under simply supported conditions and investigated bending moment experimentally and analytically. From the test results, it was found that although reinforcement of infilled concrete on the pure bending moment of PHC pile was negligible, reinforcement of PHC pile using infilled concrete and longitudinal rebars increase the maximum bending moment with range from 1.95 to 2.31 times than that of conventional PHC pile. The error of bending moment between experimental results and predicted results by nonlinear sectional analysis on the basis of the conventional layered sectional approach was in the range of -2.54 % to 2.80 %. The axial compression and moment interaction analysis for ICP piles shows more significant strengthening effects of infilled concrete and longitudinal rebars.

확장판 선단부착 PHC말뚝 및 볼트 수직이음을 사용한 PHC말뚝의 시공 중 건전성 확인을 위한 동재하시험의 적용성 및 변형시공법 PHC말뚝들의 올바른 검증시험에 관한 연구 (Study on the Applicability of Dynamic Pile Load Test to Check Integrity during Installation of Extension Plate Attached PHC Piles and Bolts Spliced PHC Piles and the Correct Proof Test of the Transformed-installation PHC Piles)

  • 김명학;최용규
    • 한국지반공학회논문집
    • /
    • 제34권12호
    • /
    • pp.115-131
    • /
    • 2018
  • 현장 시험 부지에서 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝에 대한 시험시공을 실시하고 시공중 건전성을 동재하시험으로 확인하고 시공 후 말뚝의 건전성을 직접 확인하였다. 그 결과를 분석하여 확장판 선단부착 PHC말뚝 및 볼트 수직이음 PHC말뚝의 시공 중 건전성을 동재하시험의 건전도지수(${\beta}$지수)로 평가할 수 있는지에 대하여 연구하였다. 이론적으로 말뚝 선단에 매우 인접하거나 선단끝단에서 발생하는 손상(특히 확장판 선단부착구 자체의 변형)은 시험기술의 특성상 건전도지수로 정확한 평가하는 데에는 한계가 있었다. 말뚝의 선단부에 바로 인접해서 발생하거나 말뚝선단 끝단에서의 손상을 PDA시험을 통하여 명확하게 평가하는 데에는 시험기술의 이론에 대한 고도의 지식과 경험이 요구되었다. 다른 볼트 수직이음구로 인하여 실질적인 1차원 파동전달이 용접이음에서와 다를 수 있다는 점, 타격에 의해 발생하는 응력파의 파장이 볼트 수직이음구 높이(약 100mm)보다 클 수 있다는 점, PDA 분석 기능 중 베타 프로세싱(Beta processing)이라는 기능 등이 매우 심도 있는 지식과 경험을 토대로 평가해야만 더욱 정밀한 판단이 이루어질 수 있다는 점 등을 종합적으로 고려할 때 일반적인 건전성 평가기술로 볼트 수직이음의 건전성을 평가하는 데에는 한계가 있었다.

사질토층을 지나 풍화암에 소켓된 매입 PHC말뚝에서 지반의 허용압축지지력 산정도표 및 산정공식 개발에 관한 연구(I) - 재하시험 자료 분석을 통한 전체지지력에 대한 주면마찰력의 분담율(SRF) 분석 - (Study(I) on Development of Charts and Formulae Predicting Allowable Axial Bearing Capacity for Prebored PHC Pile Socketed into Weathered Rock through Sandy Soil Layer - An Analysis of Sharing Ratio of Skin Friction to Total Bearing Capacity (SRF) by Analyzing Pile Load Test Data -)

  • 최용규;이원제;이창욱;권오균
    • 한국지반공학회논문집
    • /
    • 제35권8호
    • /
    • pp.17-30
    • /
    • 2019
  • 실제 시공된 말뚝들의 재하시험 자료 및 매입 PHC말뚝의 설계 자료로부터 전체지지력에 대한 주면마찰력의 분담율인 SRF를 분석하였다. 현장에서 시험 시공된 말뚝의 SRF는 말뚝의 종류, 상대근입길이, 지반의 종류, 재하시험의 종류에 상관없이 42~99%이었다. 매입 PHC말뚝에 대한 설계 자료에서 구한 SRF는 말뚝의 직경, 상대근입길이에 상관없이 풍화암에 소켓된 경우 20~53%의 범위에 분포하였다. 사용말뚝으로 실제 시공된 매입 PHC말뚝에서 재항타 동재하시험 자료로부터 구한 SRF는 말뚝의 직경, 상대근입길이, 지반의 종류에 상관없이 4~83%의 범위에 분산되어 분포하였다. 사용말뚝에서 SRF가 낮은 수준으로 나타나는 이유는 매입 PHC말뚝의 주면고정액의 충전이 제대로 이루어지지 않은 채 시공된 현황으로 볼 수 있었으며 따라서 주면고정액의 시공관리에서 시급하게 개선해야 할 현황이었다. 풍화암에 소켓된 매입 PHC말뚝의 설계에서 사용하고 있는 극한지지력 산정공식으로 계산한 주면마찰력의 SRF는 실제 현장 시공 말뚝의 SRF보다 평균적으로 2.2배 정도로 낮은 수준으로 평가되었다. 이는 설계에서 사용하고 있는 산정공식에 의한 극한주면마찰력이 매우 낮은 수준으로 계산되기 때문이다. 따라서 SRF를 만족시킬 수 있는 새로운 주면마찰력 산정공식의 제안 필요성이 있는 것으로 판단된다.

GNSS 기반 PHC 파일 절단위치 센싱 방법론에 관한 연구 (GNSS-Based PHC Pile Cutting Position Sensing Methodology)

  • 조세현;유건희;김준상;이준호;허제;김영석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.387-388
    • /
    • 2023
  • PHC pile head cutting is an essential work in pile foundation construction. However, since the work has labor-intensive characteristics, there are problems such as productivity and safety. So in previous study PHC pile one-cutting head cutting automation equipment was developed to solve this problem. However, it has been investigated as a limitation that checking the cutting position of the PHC pile can be challenging in place where a rotary laser leveler cannot irradiate cutting position, as the sensing unit of the developed automated equipment utilizes an optical method. Therefore, the objective of this study is to delvelop a GNSS-based methodology for sensing the cutting position of PHC piles to overcome the limitations of the optical method and to examine its feasibility for field application. If the proposed methodology is applied to the construction site, it is expected that the convenience and productivity of the PHC pile cutting position sensing work will be improved.

  • PDF

PHC파일 시공관리 문제점 및 개선방안 (Problem and Improvement Measure of PHC Pile Construction)

  • 박태규;이정철;이찬식
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2008년도 정기학술발표대회 논문집
    • /
    • pp.344-348
    • /
    • 2008
  • 최근 구조물의 고층화, 대형화 등 여러 가지 사회적 요구에 따라 기존 PC 말뚝의 개선책으로 PHC말뚝이 실용화 되었다. 현재는 대부분의 현장에서 PHC말뚝이 사용되고 있으며, 국내 콘크리트 말뚝 총 생산량의 90%이상을 점유하고 있다. 기성콘크리트 파일 공사의 굴착 및 파일 매입 작업의 국내 시방기준에는 파일을 연직으로 시공해야한다는 것만이 명시되어 있을 뿐, 이에 대한 측정기준 및 시공기준이 제시되어있지 않으며, 대부분의 시공현장에서는 숙련노무자의 경험을 통한 육안측정에 의존하고 있는 실정이다. PHC 파일의 두부정리 작업은 노동집약적이며 단순 반복적인 작업으로 숙련된 노무자에게 많이 의존해왔으며, 파일의 종 방향 균열 및 두부파손 등의 문제점이 발생되고 있다. 본 논문은 PHC 파일 시공 전 과정에서 발생되는 문제점을 분석하고 그에 대한 개선방안을 도출하기 위해 설문조사 및 면담을 실시하였다. 설문조사 및 면담을 통해 파일적재, 현장 내 소운반, 파일위치표시, 연직체크, 굴착 및 항타, 그라인딩, 안전사고의 주요 문제점을 도출하였고, 그에 대한 개선방안을 제시하였다.

  • PDF

PHC-W 흙막이 벽체를 이용한 건축물 지하증설벽체에서 PHC-W말뚝의 선단지지력 산정에 관한 연구 (A Study on Estimation of End Bearing Capacity of a PHC-W Pile in Building Underground Additional Wall Using the PHC-W Earth Retaining Wall)

  • 김채민;윤대희;이창욱;;김성수;최용규
    • 한국지반공학회논문집
    • /
    • 제35권3호
    • /
    • pp.5-16
    • /
    • 2019
  • 최근 도시 인구의 밀집으로 대형구조물의 건설이 증가하고 있으며 이와 더불어 대형구조물의 기초도 발전하고 있다. 2000년대 말에 일본의 기술을 도입하여 PHC말뚝은 많은 구조물에 사용되고 있다. 최근 PHC말뚝의 장점을 이용하여 흙막이 벽체로의 사용에 대한 연구가 많이 진행되고 있으며, 이 연구에서는 PHC-W 흙막이 벽체를 이용한 건축물 지하증설벽체에서 PHC-W말뚝을 주열식으로 시공하여 연직 압축정재하시험을 실시하였으며, 하중전이 측정을 통하여 PHC-W말뚝의 선단지지력을 산정하였다. 풍화암에 근입된 PHC-W말뚝의 지지력은 기존 PHC말뚝의 지지력과는 차이를 보였으므로, 주열식으로 시공된 PHC-W말뚝의 선단지지력 산정식을 제안하였다. 풍화암에 근입된 PHC-W말뚝의 단위극한선단지지력 산정식으로 주열식 군PHC-W말뚝과 단일PHC-W말뚝에서 각각 $q_b=6.8N_b$$q_b=13.3N_b$로 제안할 수 있었다.

코일형 PHC 에너지파일의 열적 거동 및 설계법에 관한 연구 (Study on Thermal Behavior and Design Method for Coil-type PHC Energy Pile)

  • 박상우;손정락;박용부;류형규;최항석
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.37-51
    • /
    • 2013
  • 에너지파일은 말뚝 내부에 열교환을 위한 순환파이프를 설치하여 파이프 내에 열전달 유체를 순환시킴으로써 주변 지반의 열에너지와 말뚝 간의 열교환을 가능하게 한 구조물이다. 에너지파일은 기존의 지중 열교환기와 비교하여 경제적, 시공적인 측면에서 많은 장점을 가지고 있다. 본 논문에서는 코일형 PHC 에너지파일을 시공하여 그 열적거동을 실험 및 수치해석을 통하여 평가하였으며, 해당 에너지파일의 예비설계를 수행하였다. 현장 시공된 코일형 PHC 에너지파일에 대한 현장 열응답시험(thermal response test, TRT)를 실시하고, 이 결과를 Man et al.(2010)이 제안한 개선된 원통형 열원 모델(solid cylinder source model) 결과와 비교하였다. 또한 현장 열응답 시험 결과를 FLUENT를 이용한 전산유체(computational fluid dynamics, CFD) 수치해석을 통해 모사함으로써, 대상 지반의 열전도도를 역해석을 통해 산정하였다. 코일형 PHC 에너지파일에 설치된 코일형 열교환 파이프의 파이프 루프 간 간격에 따른 열간섭을 평가하기 위하여 코일피치에 변화를 주며 수치해석을 수행하였으며, 결과를 통해 코일피치에 따른 에너지파일의 열거동 및 열교환 효율을 평가하였다. 마지막으로 수치해석을 통해 코일형 PHC 에너지파일과 일반적인 복합 U-형 열교환 파이프가 삽입된 PHC 에너지파일 간의 열교환 효율을 비교하여 코일형 PHC 에너지파일의 등가 열교환율(또는 등가 환산계수)을 제시하였고, 이를 PILESIM2를 이용한 설계 알고리즘에 적용함으로써 해당 에너지파일의 예비설계를 수행하였다.

PHC 파일 두부정리 자동화 장비의 말단장치 개발 (Development of the End-effector for Developing a PHC Pile Cutting and Crushing Machine)

  • 이정호;김영석;조문영;김성근;성낙원
    • 한국건설관리학회:학술대회논문집
    • /
    • 한국건설관리학회 2004년도 제5회 정기학술발표대회 논문집
    • /
    • pp.531-534
    • /
    • 2004
  • 재래식 두부정리 작업은 노동 집약적이며 노무자간의 숙련도 차이에 의해 품질 및 작업 생산성이 크게 영향을 받고 있다. 국내 $\cdot$ 외에서는 두부정리 작업의 생산성 및 안전성, 품질을 향상시키기 위해 자동화 장비를 개발 중에 있으나 기존에 개발된 두부정리 자동화 장비는 파일 파쇄 작업만을 자동화 대상으로 하고 있고, PHC 파일에 종방향 균열을 발생시켜 두부정리 작업의 품질을 크게 저하시키고 있는 실정이었다. 기존 두부정리 자동화 장비가 PHC 파일에 종방향 균열을 발생시키는 원인은 PHC 파일의 물리적 특성을 고려한 자동화 장비 말단장치의 설계 및 제작, 배치가 제대로 이루어지지 못한 것으로 분석되었다. 따라서, 본 연구에서는 기존에 개발된 두부정리 자동화 장비 및 본 연구를 통해 현재까지 개발된 두부정리 자동화 장비 파일롯타입의 실험결과를 토대로 PHC 파일을 종방향 균열 없이 효과적으로 파쇄할 수 있는 두부정리 자동화 장비 프로토타입의 말단장치를 개발하고자 한다.

  • PDF

무소음.무진동 스크류 PHC 말뚝의 응력평가를 위한 유한요소해석 (FE Analysis for a Stress Evaluation of a Noise & Vibration-Free Screw PHC Pile)

  • 정호영;최영휴;오승률;김성수;최용규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.561-570
    • /
    • 2009
  • A FE analysis of a noise & vibration-free screw PHC pile constructed into an in-situ site were performed. During constructing a screw PHC pile, the component stresses, maximum stresses of pile connecting parts and relative displacements of pile were analyzed.

  • PDF