• Title/Summary/Keyword: PC-12

Search Result 1,768, Processing Time 0.024 seconds

Face Feature Extraction for Face Recognition (얼굴 인식을 위한 얼굴 특징점 추출)

  • Yang, Ryong;Chae, Duk-Jae;Lee, Sang-Bum
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.12
    • /
    • pp.1765-1774
    • /
    • 2002
  • A face recognition is currently the field which many research have been processed actively. But many problems must be solved the previous problem. First, We must recognize the face of the object taking a location various lighting change and change of the camera into account. In this paper, we proposed that new method to fund feature within fast and correct computation time after scanning PC camera and ID card picture. It converted RGB color space to YUV. A face skin color extracts which equalize a histogram of Y ingredient without the luminance. After, the method use V' ingredient which transformes V ingredient of YUV and then find the face feature. The reult of the experiment shows getting correct input face image from ID Card picture and PC camera.

  • PDF

MOLECULAR CLOUD ASSOCIATED WITH AFGL 2591

  • Minh, Y.C.;Yang, Ji
    • Journal of The Korean Astronomical Society
    • /
    • v.41 no.5
    • /
    • pp.139-145
    • /
    • 2008
  • The molecular cloud, embedding AFGL 2591, has a "head-and-tail" structure with a total mass of ${\sim}\;1800\;M_{\odot}$, about half of the mass (${\sim}\;900\;M_{\odot}$) in the head (size ${\sim}\;1.2\;pc$ in diameter), and another half in the envelope (${\sim}\;3.5\;pc$ in the east-west direction). We found a new cloud in the direction toward north-east from AFGL 2591 (projected distance ${\sim}\;2.4\;pc$), which is probably associated with the AFGL 2591 cloud. The $^{12}CO$ spectrum clearly shows a blue-shifted high-velocity wing at around the velocity $-20\;{\sim}\;-10\;km\;s^{-1}$, but it is not clear whether this high-velocity component has a bipolar nature in our observations. The observed CN spectra also show blue-shifted wing component but the existence of the red-shifted component is not clear, either. In some CN and HCN spectra, the highvelocity components appear as a different velocity component, not a broad line-wing component. The dense cores, traced by CN and HCN, exist in the 'head' of the AFGL 2591 cloud with an elongated morphology roughly in the north-south direction with a size of about 0.5 pc. The abundance ratio between CN and HCN is found to be about 2 - 3 within the observed region, which may suggest a possibility that this core is being affected by the embedded YSOs or by possible shocks from outside.

Effect of ${\beta}$-Sitosterol in Liposome Bilayer on the Stabilization of Incorporated Retinol

  • Lee, Seung-Cheol;Kim, Jin-Ju;Lee, Kyung-Eun
    • Food Science and Biotechnology
    • /
    • v.14 no.5
    • /
    • pp.604-607
    • /
    • 2005
  • In this study, the effect of ${\beta}$-sitosterol (SS) in the liposome bilayer on the stability of incorporated retinol was evaluated. Retinol was incorporated into liposomes consisting of various ratios of soybean phoaphatidylcholine (PC) to SS, while liposomes were prepared as multilamellar vesicles by the dehydration/rehydration method. Retinol was readily incorporated into liposomes with various SS contents, with incorporation efficiencies higher than 98% for all conditions. The incorporation efficiency of retinol increased slightly as the SS content in liposomes increased. Its average particle size also increased as the SS content increased. Mean particle size at PC to SS ratios of 100:0, 90:10, 80:20, 70:30, 60:40, and 50:50 were 12.16, 17.57, 35.00, 40.62, 83.45, and $88.94\;{\mu}m$, respectively. Liposomal retinol degradation in aqueous solution was measured with respect to SS content at various periods of time at four different temperatures of 4, 25, 37, and $50^{\circ}C$, and the stability of the incorporated retinol enhanced as the SS content increased. At $4^{\circ}C$, for example, retinol in the liposomes of 50:50 (PC:SS) remained at 84.42% after storage for 10 days, while in 100:0 (PC/SS) it remained at 42.62%. These results indicate that SS content in liposomes played an important role in the incorporation efficiency of retinol and its stability.

User's Perception Characteristics on Color and Contrast for Designing the Interface of a Combined PC and TV Monitor (PC&TV 겸용모니터의 인터페이스 디자인을 위한 사용자의 색채 및 대비 지각 특성)

  • Jeong, Gwang-Tae;Park, Jae-Hui
    • Journal of the Ergonomics Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.25-32
    • /
    • 1998
  • A combined PC and TV monitor has been developed in several companies. The characteristics of physical user interface in this monitor are likely to vary from existing monitors. Therefore, two experiments to investigate the physical interface characteristics of this monitor were conducted. The first experiment was to investigate the characteristics of color perception with monitor coating (coating vs. non-coating) and screen brightness (30fL vs. 35fL) in the PC mode. The second experiment was to investigate the characteristics of luminance contrast with monitor coating and image movement (static vs. dynamic) in the TV mode. Twenty-three subjects (male 12, female 11) were participated in this experiment. In the first experiment, average color temperatures were obtained in all experimental conditions. There was a significant difference between coating and non-coating screen at 0.1 level. In the second experiment, average luminance contrasts were obtained in all experimental conditions. There was a significant difference between coating and non-coating screen at 0.05 level. In addition, there was a significant difference between static picture and dynamic picture at 0.1 level.

  • PDF

Related Factors of Upper Limb Musculoskeletal Disease in Small-to-Medium-sized Manufacture Enterprises Workers (중소규모 제조업 근로자의 상지 근골격계질환 발생에 영향을 미치는 요인)

  • Kim, Hye-Jin;Jung, Hye-Sun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.13 no.1
    • /
    • pp.19-29
    • /
    • 2004
  • Purpose: This study was conducted at small-to-medium-sized manufacture enterprises less than 300 employees. Method: For 167 workers in 12 small-to-medium-sized manufacture, we examined the self-recording questionnaires about general characteristics, health characteristics, occupational characteristics and subjective musculoskeletal symptoms designed by NIOSH. Result: Related factors of upper limb musculoskeletal symptoms were found in using of the PC except work, the speed control at working and inappropriate positions for neck, and that using of the PC except work, the degree of intensity at working and the speed control at working for shoulder, and that the degree of intensity at working, the speed control at working, inappropriate positions and excessive workforce for arm/elbow, and that the degree of intensity at working, the speed control at working, inappropriate positions, excessive strong and vibration for hand/wrist/fingers. Conclusion: As a result of multiple logistic regression analysis, musculoskeletal symptoms of neck were influenced by use of the PC except work, household work, and the speed control at working, symptoms of shoulder by using of the PC of except work and the degree of intensity at working, symptoms of arm/elbow by the speed control at working, and symptoms of hand/wrist/fingers by the degree of intensity at work and excessive workforce.

  • PDF

A High-speed Miniature Screening Gaschromatograph with Flame Ionization Detector

  • Banik Rahul;Lee Dong-Yeon;Gweon Dae-Gab
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2197-2204
    • /
    • 2005
  • The combination of Gas chromatography (GC) for separation and Flame Ionization Detection (FID) for detection and identification of the components of a mixture of compounds is a fast and strongly proved method of analytic chemistry. The objective of this research was to design a combined High-speed miniature screening Gas chromatograph along with a Flame Ionization Detector for quick, quantitative and qualitative analysis of gas components. This combined GC-FID system is suitable to detect the volatile and semi-volatile hydrocarbons present in a gas mixture. The construction made it less expensive, easy to use and movable. The complete gas path was developed. On/off valves, temperature and flow sensors and their interface electronics were used for controlling purpose. A Microcontroller was programmed to measure the temperature and gas flow using the sensors and to control and regulate them using the electronics and valves. A pocket PC with its touch screen served as a user interface for the system. Software was developed for the pocket PC, which makes the communication possible with the Microcontroller. The system parameters can be indicated in the Pocket PC as simple text and also the analysis result can be displayed.

Impact Characteristics of AFRP Reinforced Concrete Slab (AFRP 보강 콘크리트 슬래브의 충격 특성에 관한 연구)

  • Park, Sung-Jin
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.4
    • /
    • pp.492-500
    • /
    • 2018
  • Purpose: In this paper, based on this background, the main purpose of studying the behavior of concrete slab reinforced with new material fiber in impact loading is investigated by AFRP using aluminum fiber. Results: Research on the use of new materials as reinforcing materials for concrete members has been carried out in many fields such as flexural and shear tests under static loading, fatigue loading under cyclic loading, and application to PC beams. However, And the issue of plate elements is still at a basic stage. Conclusion: In this paper, the dynamic behavior of reinforced concrete slabs is investigated by using AFRP rod reinforced with aluminum fiber.

Effect of Family Size and Genetic Correlation between Purebred and Crossbred Halfsisters on Response in Crossbred and Purebred Chickens under Modified Reciprocal Recurrent Selection

  • Singh, Neelam;Singh, Raj Pal;Sangwan, Sandeep;Malik, Baljeet Singh
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.1
    • /
    • pp.8-12
    • /
    • 2005
  • Response in a modified reciprocal recurrent selection scheme for egg production was evaluated considering variable family sizes and genetic correlation between purebred and crossbred half sisters. The criteria of selection of purebred breeders included pullet's own performance, purebred full and half sisters and crossbred half sister's performance. Heritability of egg production of crossbreds (aggregate genotype) and purebred's was assumed to be 0.2 and genetic correlation between purebred and crossbred half sisters ($r_{pc}$) as 0.1, 0.2, 0.3, 0.4, 0.5, 1.0, -0.1, -0.2, -0.3, -0.4, -0.5 and -1.0. Number of dams per sire to produce purebred and crossbred progenies assumed to be 5, 6, 7, 8, while number of purebred female progeny ($N_p$) and crossbred progeny ($N_c$) per dam were considered to be 3, 4, 5 and 6 in each case. Considering phenotypic variance as unity, selection indices were constructed for different combinations of dams and progeny for each value of $r_{pc}$. Following selection index theory, response in crossbred and purebred for egg production was computed. Results indicated that response in crossbreds depended mainly on crossbred family size and also on magnitude of$r_{pc}$ irrespective of its direction, and response was greater with large crossbred family size than the purebred families. Correlated response in purebreds depends both on magnitude and direction of $r_{pc}$ and was expected to be greater with large purebred family size only. Inclusion of purebred information increased the accuracy of selection for crossbred response for higher magnitude of$r_{pc}$ irrespective of its direction. Present results indicate that desirable response in both crossbred and purebred performance is a function of $r_{pc}$ and family sizes. The ratio of crossbred and purebred family sizes can be optimized depending on the objective of improving the performance of crossbreds and/or of purebreds.

Numerical Study on the Leakage Safety of the Membrane LNG Tank Wall (멤브레인식 LNG 탱크벽체의 누설안전에 관한 수치해석적 연구)

  • Kim, Chung-Kyun;Shim, Jong-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.4
    • /
    • pp.14-20
    • /
    • 2008
  • In this numerical study, the leakage safety of the LNG tank in which is constructed by membrane inner tank-plywood-polyurethane form-plywood-prestressed concrete structures has been presented for four leakage analysis models. The LNG leak criterion of the tank wall with a storage capacity of $200,000\;m^3$ is analyzed based on the thermal resistance technique. This means that if the cryogenic temperature of a leaked LNG is detected at the outer side of the PC wall, it may be leaked through the wall thickness of the tank. The calculated results based on the thermal resistance method between two walls show that the plywood, PUF, and another plywood walls may block the leakage of the leaked LNG even though the strength of these walls is already collapsed by a leaked LNG pressure. But, the leaked LNG may pass the thickness of the prestressed concrete wall for a period of elapsed time even though the PC outer tank supports the leaked LNG pressure. Thus, the PC outer tank may extend the leakage time of a leaked LNG.

  • PDF

Study for Addition Effect of Propylene Carbonate to 1-ethyl-3-methylimidazolium in Electric Double Layer Capacitors (Propylene Carbonate 첨가된 1-ethyl-3-methylimidazolium의 전기이중층 커패시터에서의 효과)

  • Kim, Hyun-Chul;Yang, Jeong-Jin;Kim, Han-Joo;Sin, Dal-Woo;Park, Soo-Gil
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • Because the ionic liquid added with Propylene carbonate(PC) at room temperature has lower viscosity than original, we considered electrochemical behavior of it in EDLC. The ionic liquid without PC which does not have ions has no problem in capacity since it has enough ions. The electrolyte resistance was decreased with decreasing viscosity. As a result of identifying high current discharge capacity, we observed that the ionic liquid had capacity of 73.12% at current density of $80\;mA/cm^{-2}$, but it increased to 81.94% at PC content of 40 vol%.