• Title/Summary/Keyword: Ozone Generator

Search Result 99, Processing Time 0.031 seconds

The Invert for ozone generator by mixed square_wave and PWM (구형파 및 PWM 인버터 조합에 의한 오존발생용 인버터)

  • Park Noh-Sik;Park Sung-Jun;Won Tae-Hyun;Ahn Jin-Woo;Kim Cheul-U
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1193-1195
    • /
    • 2004
  • Ozone gas is one of the strongest oxidizing and bleaching agents which leave no residues harmful to the global environment. In recent years, the ozone generator has been widely utilized, However, it has been known that a broader application of ozone is hindered primarily because of its low efficiency of generation. Thus, it is more indispensable to improve actual system efficiency of the silent discharge type ozonizer using high frequency inverter. This paper presents a multi level resonant ozone power regulation by association of high frequency transformers and full bridge invert. And proposed resonant inverter system can generate continuous output voltage. can control linearly quantity of ozone gas. This invert that add PWM forms within square forms of output voltage about one level range. The power regulation characteristics and operating performances of silent discharge (SD)type ozone generating tube load driven by this load proposed inverter using FET modules are illustrated from a practical point of view, which can operate under stable conditions of basic level and PWM hybrid control strategy implemented DSP(2406). The effectoveness of propsed invert type ozonizer is proved by experiment results.

  • PDF

A Study on the Development of Bleaching efficiency for flex fabrics by Using Ozone Treatment (오존을 이용한 마직물의 표백성 향상에 관한 연구)

  • Lee, Mun-Soo;Song, Kyong-Hun;Kim, Gyoung-A;Song, Bong-Keun;Lee, Rae-Yohn
    • The Journal of Natural Sciences
    • /
    • v.10 no.1
    • /
    • pp.93-102
    • /
    • 1998
  • In order to study on the bleaching efficiency of flex fabrics, ozone which has been produced by an ozone generator, has been contacted with flex fabrics in water at various conditions. The equipments used for the ozone reatment of flex fabrics were the ozone generator and a liquor/ozone contactor. For the study of the bleaching efficiency on flex fabrics, the Hunter's whiteness, tensile strength, microscopic properties of the ozone treated flex fabrics were measured. The concentration of generated ozone was increased, as the voltage increase, flow ratio decrease and oxygen amount increase. The bleaching efficiency of ozone treated fabrics was increased with increasing the net concentration of ozone. The whiteness ozone of treated fabrics was found to be best when treated temperature was $0-15^{\circ}C$ and treated time was 20 min. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised.

  • PDF

Development of the Ozone Generator with Silent Discharge Type for Clean Environment (친환경적인 무성방전형 오존발생기 개발)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hyeong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.11c
    • /
    • pp.562-564
    • /
    • 2000
  • The optimization of electrode geometry is the most important technology for producing the ozone with high concentration and efficiency. An optimization method for a discharge gap, an air cleaner equipment, voltage apply device, pressure and air flow quantity. In our experiments, the high frequency power were applied to the discharge gap with 23-1G(Silent Discharge). The ozone characteristics was measured with air as a supplied gas, which can be used as basic data for the development of small size ozone generator.

  • PDF

Techniques of Water Quality Improvement by Using Ozone Generation System (오존발생시스템을 이용한 하천수질 개선기법)

  • Kim, Min-Young;Ryu, Jae-Wook;Lee, Seung-Yun;Jee, Hong-Kee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2122-2126
    • /
    • 2008
  • With the degradation of water quality and, at the same time increased water usage, the sources of high quality, for examples, river/stream, municipal reservoir, wells, artisan and surface water, are diminishing. Therefore, the importance of water quality has been emphasized over the years through publications and various literature sources. Even though considerable research has resulted in significant strides for providing interpretive information and mitigation strategies for improvement of waters, the quality of which is still questionable. This study aims to propose a completely independent self-contained system for purifying waters, solar-powered ozone generator. It is a semi-permanent and cost effective environmental solution. Functions of ozone treatment are: 1) to maintain oxidative flexibility, 2) remove harmful chemicals, wastes, and other substances, and 3) prevent epizootic microbial outbreaks. Recent advances in technology have allowed the development of the practical, self-contained and independent solar powered device. Solar electrical producing panels that charge batteries are the key to using these systems anywhere electrical power is not available. This paper invites the readers to examine the problem and consider the viable, proven solution the solar powered ozone purifying system. This paper also introduces basic concept and background of solar powered ozone generators and examine its feasibility for improving water quality in rivers and streams.

  • PDF

A Study on the Bleaching of Cotton Fabrics by utilizing Ozone(($O_{3}$) (오존($O_{3}$)을 이용한 면직물의 표백에 관한 연구)

  • Cho, Hwan;Seo, Mal Young;Yu, Jae Sun;Lee, Byung Hyun;Huh, Man Woo;Lee, Kwang Woo;Cho, In Sul;Jong, Hee Cheon
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.49-59
    • /
    • 1993
  • In order to study the bleaching of cotton fabrics, ozone which has been produced by an ozone generator, has been contacted with cotton fabrics in water at various conditions. The equipments used for the ozone treatment of cotton fabrics were the ozone generator and a liquor/ozone contactor. For the examination of the ozone bleaching effect on cotton fabrics the whiteness, tensile strength, wettability and clark softness of the ozone treated cotton fabrics were measured. The conclusion obtained were, ozone concentration was increased, as the voltage was increased and flow rate was decreased and oxygen amount was increased. Bleaching effect of treated fabrics increased with increasing attributed more the net concentration of ozone rather than the total ozone amount of produced. The whiteness of treated fabrics was found to be best when treating temperature was 15~20<$^{\circ}C$, in acidic condition. The tensile strength of treated fabrics decreased as the treating time increased, and as the temperature raised, and the acidity increased. The wicking distance of treated fabrics increased slightly with increasing the treating time and the temperature. Clark softness of treated fabrics was not changed until passing 30min. of the treating time, then it decreasing linealy with increasing the treating time.

  • PDF

Measurement Technique of Ozone Density by Using UV Sensor System

  • Trung, Nguyen Huu;Van Men, Le;Van Hieu, Nguyen
    • Journal of IKEEE
    • /
    • v.19 no.1
    • /
    • pp.80-86
    • /
    • 2015
  • There are many studies and products using a test paper impregnated with chemical solution can react with ozone. The color of a test paper can indicate the concentration of ozone. The purpose of this research is to design and manufacture a system using ultraviolet light source to measure the ozone density. This new technique is based on the characteristic of decomposition from ozone into oxygen under ultraviolet light. We used two sources of ultraviolet light including UV lamp and UVLED to determine the decomposition of ozone. This system is built with the electronic components, sensors and sealed pump tube to measure the ozone density in units of $g/cm^3$,ppm,ppb. In this paper,, we present some initial results of measuring the ozone density from ozone generator after completing inspection for safety.

The Study on the Development of Ozone Water Diffusion Device by Ozonated Olive Oil Mix Ratio that will Increase (올리브 오일의 오존화 혼합비율을 높여주는 오존수 확산장치개발에 관한 연구)

  • Kim, Duck-Sool
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.4
    • /
    • pp.688-693
    • /
    • 2014
  • This study is to increase the utilization of the ozonated water generator to make it easier to take advantage of the ozone water in the world today, there will be to develop a system that operates in one motion. Furthermore, olive oil and ozone is reacted with the wish to apply to the manufacturing technology. In the case of many existing products ozone generator driven mostly non-ozone system. In the case of ozone, but handwriting is implied general way pressure ozone gas leakage risks of suction force to the pump, it is the case of the challenge by using the injector, and limit the generation of ozone and ozone inhalation according to whether the water inlet leakage of existing products risk due to minimized. Despite the disadvantages of the injector system was found the effectiveness of the ozonated water production unit injector system used in this study to maintain the microbiological disinfection performance.

Optical Ozone Monitor Using UV Source

  • Chung, Wan-Young
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.49-52
    • /
    • 2003
  • Two types of ozone monitors using UV absorption method were tried in consideration of cost of the monitor and precision in measuring. The high concentration ozone monitor for high concentration real time ozone monitoring from ozone generator was composed of a low pressure mercury lamp as UV source, a photo multiplier tube as UV detector and signal processing unit for the most part. This structure could be very useful for low price high concentration ozone monitor due to simple system structure and fairly good monitoring characteristics. The developed system showed good linear output characteristics to ozone in the measuring concentration range of 0.05 and 2 wt.%. For accuracy ambient ozone monitoring in ambient in ppm level, the system composed of a high power pulsed xenon lamp as UV source, an optical spectrometer with a high sensitivity linear CCD array as UV detector and signal processing unit in brief speaking was proposed our study for the first time in the world. The developed system showed good linearity and sensitivity in relative low measuring range between 10ppm and 10,000ppm, and showed some feasibility of high resolution ozone monitor using CCD array as photodetector.

  • PDF

Silent Disicharge Characteristics of Alumina Discharge Tube for Ozone Generation (오존발생을 위한 알루미나 방전관의 무성방전특성)

  • 김학규;곽동주
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.783-786
    • /
    • 2001
  • Recently deep interests and attractions have been paid on the generation of ozone, which is widely used to remove bad smell and to clear water. Silent discharge is considered as one of the most effective methods to generator ozone. In this paper, silent discharge reactors were made, waich were filled with different dielectric materials, and some silent discharge charactistics were investigated experimantaiiy.

  • PDF

Effects of Properties of Binder between Electrode and Dielectric Barrier on Ozone Generation Characteristics (전극과 유전체장벽간의 접착물질의 물성변화가 오존발생특성에 미치는 영향)

  • 박승록;김진규;김형표
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.119-125
    • /
    • 2002
  • The temperature decrease of discharge space was very important to generate the high concentration of ozone in silent discharge type ozone generator. At this time, binding materials and methods between dielectric barrier and ground electrode affected to the discharge importantly in electrical and thermal point of view. So, above two factors become very important parameters should be considered before designing the ozone generator. In this study, binders of silicone compound, electroconductive resin and charcoal were used for variations of binders properties. Resultantly, when the binding materials were used, better ozone generation characteristics were shown(maximum ozone generation 28044[ppmV] at 6.0[kV]) in comparison with the non-used case (maximum ozone generation 15944[ppmV] at 4.0[kV]). In addition, when the binding materials were used, the case of pure silicone compound showed better characteristics(maximum ozone generation 28044[ppmV] at 6.0[kV]) than the cases of conductive binding materials(maximum ozone generation 25842[ppmV] at 5.5[kV] and including the charcoal 5%).