Characteristics of Sparkover Discharge In Flowing Air With Variation of Temperature (온도변화를 고려한 유동공기의 방전특성에 관한 연구)

  • 김상구;오재열;송현직;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1991.10a
    • /
    • pp.28-32
    • /
    • 1991
  • This paper reports the characteristics of sparkover discharge in flowing air with variation of Temperature(T). Also, We studied changes of discharge pattern for constant input power by adjustment of the reynolds number(Re) and T. the essentials of this paper are as followers. The invaluable equation obtained from this experiment is [%] {{{{ { Vs} over {Re } = A·LOG10 Re + B}}}} w here A,B : constant Breakdown Voltage for variation of temperature at 1[m/s] is given by expression Vs = K(23.98 pd + 6.8{{{{ SQRT { pd} }}}}) [kV] where K = 0.331 The discharge pattern can be controlled by adjustment of the Reynolds number

  • PDF

RF Glow Discharge and TiN Thin Film Characteristics in a Plane Electrode System (평판형 전극계의 RF 글로우 방전특성 및 TiN 박막특성)

  • Kwak, D.J.;Kim, D.H.;Kim, H.J.;Park, C.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1838-1840
    • /
    • 1996
  • In order to study the relationship between the physical properties of glow discharge plasma and the physical behavior of TiN thin film, electrical characteristics of RF discharge plasma driven at 13.56MHz in a parallel-plate electrode system were measured. Plasma parameters, such as electron density and temperature, are also studied since they may be considered as one of the very important factors deciding the physical properties of TiN thin film under given conditions of applied biasd voltage and pressure. The TiN thin film were fabricated over a wide range of discharge conditions, and some of the general relationships between the measured plasma parameters and the properties of TiN thin film were discussed.

  • PDF

Flexible Plasma Sheets

  • Cho, Guangsup;Kim, Yunjung
    • Applied Science and Convergence Technology
    • /
    • v.27 no.2
    • /
    • pp.23-25
    • /
    • 2018
  • With respect to the electrode structure and the discharge characteristics, the atmospheric pressure plasma sheet of a thin polyimide film is introduced in this study; here, the flexible plasma device of a dielectric-barrier discharge with the ground electrode and the high-voltage electrode formulated on each surface of a polyimide film whose thickness is approximately $100{\mu}m$, that is operated with a sinusoidal voltage at a frequency of 25 kHz and a low voltage from 1 kV to 2 kV is used. The streamer discharge is appeared along the cross-sectional boundary line between two electrodes at the ignition stage, and the plasma is diffused on the dielectric-layer surface over the high-voltage electrode. In the development of a plasma sheet with thin dielectric films, the avoidance of the insulation breakdown and the reduction of the leakage current have a direct influence on the low-voltage operation.

The Fundamental Study About Partial Discharge Detection With The Radiated Electromagnetic Wave Characteristics (방사전자파 특성을 이용한 부분방전 검출의 기초연구)

  • Lee, Sang-Hun;Park, Gwang-Seo;Kim, Chung-Nyeon;Lee, Hyeon-Dong;Song, Hyeon-Jik;Kim, Gi-Chae;Lee, Gwang-Sik;Lee, Dong-In
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.7
    • /
    • pp.412-417
    • /
    • 2000
  • This paper offer fundamental materials about Partial Discharge(PD) detection by electromagnetic waves. All spectrum data-usually used as grape- can be used as numbers. And then the average of background noise spectrum strength was made. Average value subtract from every data. Then average value appeared, graphed. The graph was compared with the magnitude of charge. The shape of changes is similar, and the change of electric field strength could be seen in one sight. When the magnitude of charge is over than 100[pC], antenna can detect partial discharge. So this method will be very useful to diagnosis of insulation. It the performance of the antenna used in this experiment is analyzed, good results can be obtained.

  • PDF

Emission Characteristics of Discharge Tube with Mixed Gases

  • Jo, Ju-Ung;Park, Yong-Sung;Lee, Jong-Chan;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.3C no.4
    • /
    • pp.136-139
    • /
    • 2003
  • The positive column of a discharge tube filled with a mixture of mercury-xenon has a tendency to become contracted at room temperature. However, once the tube temperature is raised over 50 [$^{\circ}C$], the positive column changes from a contracted state to a diffused state. The xenon emission is stronger in the contracted positive column than in the diffused column. Alternatively, the mercury emission is more intense in the diffused positive column, and the luminance of the phosphor coating on the inner surface of the tube is higher than that in the contracted positive column. Moreover, higher luminance can be obtained by increasing the xenon pressure.

Machining Characteristics of SKS3 in Wire Cut Electrical Discharge Machining (합금공구강 SKS3의 와이어컷 방전가공 특성)

  • Ko, Beong-Du;Sin, Myong-Cheol
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.5
    • /
    • pp.101-106
    • /
    • 2008
  • In the wire cut electrical discharge machining, the optimal machining parameters setting satisfying the requirements of both high efficiency and good quality is very difficult because its process involves a series of complex physical phenomena and the machining parameters are numerous over diverse range. In this paper, the experimental investigation has been performed to find out the influence of the machining parameters on the machining performance such as cutting speed and surface roughness. The selected experimental parameters are no load voltage, discharge peak current and pulse-off time. The experimental results give the guideline for selecting suitable machining parameters.

Flat Fluorescent Lamp for LCD Backlighting (LCD 후면 광원용 평판형광램프)

  • Kwon, Soon-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.2
    • /
    • pp.15-19
    • /
    • 2007
  • A 15[inch] diagonal mercury-free flat discharge lamp with insulated electrode has been developed as backlight for a LCD backlighting. When the drive voltage pulse conditions were set properly, a uniform and stable discharge extends over the entire volume. It was obtained luminance of $10,330[cd/m^2]$ without prism sheet in uniform and stable discharge.

Low-Pressure Mercury-Free Fluorescent Lamp for General Lighting

  • Jinno, Masafumi;Lee, Jong-Chan;Motomural, Hideki;Aono, Masaharu;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.11-14
    • /
    • 2004
  • In this paper we report on development of our original mercury-less fluorescent lamps for general lighting. These new-type lamps have multi-pairs of electrodes to maintain multi-discharge paths and to keep positive column diffused state. The omission characteristics oft the lamps were investigated. These discharge lamps were operated by pulsed discharge. By using multi-pairs of electrodes for xenon pulsed discharge fluorescent lamps, higher intensity of luminance was obtained than the conventional type of lamps using single pair of electrodes. Recently this type of lamp achieved over $9000\;cd/m^2$ and 50 lm/W.

  • PDF

The Reduction of Address Discharge Delay Time Using a New Driving Method (새로운 구동방식을 이용한 어드레스 방전 지연시간의 감소)

  • Song, Keun-Young;Kim, Gun-Su;Seo, Jeong-Hyun;Lee, Seok-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 2004.11a
    • /
    • pp.123-125
    • /
    • 2004
  • In order to achieve high efficiency and low cost, new high-speed addressing method is suggested. This can be achieved by reducing the address discharge delay time through the priming effect. This paper suggests a new ADR (Address During Reset) driving method which provides priming particles by using a separated driving method without adding auxiliary electrode or auxiliary discharge. The experimental results show an approximately loons reduction in the formative delay time of address discharge and a reduction in jitter of over 200ns. Also, due to enough time being available for reset, there was a reduction in light emitted during reset of about 29% which improved the dark contrast ratio considerably.

  • PDF

UHF Sensor Location Optimization for Partial Discharge Signals Detection Method (UHF 센서 위치 최적화로 부분방전 신호 검출 방법)

  • Choi, Mun-Gyu;Cha, Hanju
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.3
    • /
    • pp.409-413
    • /
    • 2014
  • GIS partial discharge that occurred in the UHF band signal is effectively detected by the method to IEC60270 5pc the apparent minimum discharge can be detected over the GIS arrangement of the sensor interior and exterior of the UHF in accordance with the optimized position signal by considering the damping ratio is selected so that the signals can be obtained to be mounted. 362kV, 800kV GIS is installed on the internal and external sensors are UHF band signal attenuation is set by measuring the reference value, but the operation, 170kV case 362kV, 800kV on the basis of the measurement data and to be installed and operated. When 170kV per 1Bay by installing the built-in sensor 1 for detecting a partial discharge signal, But, GIS signal attenuation is large in the case of an internal partial discharge signal is not detected in some cases. Where the attenuation is great UHF signal of the sensor by increasing the quantity of partial discharge signals were acquired to allow relocation. The greater the spacing between the sensor and the sensor is applied simplifies the installation and reduces the cost in terms of maintenance of appropriate optimal position is calculated to detect the partial discharge signal is needed. Thus 170kV GIS signal power attenuation of a partial discharge by measuring the UHF sensor, and by relocating the proper position is calculated in accordance with the sensor signal decay rate and minimize the error of omission in detecting a partial discharge signal was optimized.