• 제목/요약/키워드: Outlet

검색결과 2,616건 처리시간 0.027초

냉매 내 수분의 혼입량이 차량 에어컨의 냉각성능에 미치는 영향 (Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner)

  • 문성원;민영봉;정태상
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.319-325
    • /
    • 2011
  • This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.

Analysis of Airflow Pattern in Plant Factory with Different Inlet and Outlet Locations using Computational Fluid Dynamics

  • Lim, Tae-Gyu;Kim, Yong Hyeon
    • Journal of Biosystems Engineering
    • /
    • 제39권4호
    • /
    • pp.310-317
    • /
    • 2014
  • Purpose: This study was conducted to analyze the air flow characteristics in a plant factory with different inlet and outlet locations using computational fluid dynamics (CFD). Methods: In this study, the flow was assumed to be a steady-state, incompressible, and three-dimensional turbulent flow. A realizable k-${\varepsilon}$ turbulent model was applied to show more reasonable results than the standard model. A CFD software was used to perform the numerical simulation. For validation of the simulation model, a prototype plant factory ($5,900mm{\times}2,800mm{\times}2,400mm$) was constructed with two inlets (${\Phi}250mm$) and one outlet ($710mm{\times}290mm$), located on the top side wall. For the simulation model, the average air current speed at the inlet was $5.11m{\cdot}s^{-1}$. Five cases were simulated to predict the airflow pattern in the plant factory with different inlet and outlet locations. Results: The root mean square error of measured and simulated air current speeds was 13%. The error was attributed to the assumptions applied to mathematical modelling and to the magnitude of the air current speed measured at the inlet. However, the measured and predicted airflow distributions of the plant factory exhibited similar patterns. When the inlets were located at the center of the side wall, the average air current speed in the plant factory was increased but the spatial uniformity was lowered. In contrast, if the inlets were located on the ceiling, the average air current speed was lowered but the uniformity was improved. Conclusions: Based on the results of this study, it was concluded that the airflow pattern in the plant factory with multilayer cultivation shelves was greatly affected by the locations of the inlet and the outlet.

냉장고 배출수 응축기 입출구 배관에서의 온도 특성에 관한 연구 (A Study on the Temperature Characteristics at the Inlet and the Outlet Pipes of a Refrigerator Drain Condenser)

  • 하지수;김태권
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.247-255
    • /
    • 2014
  • 본 연구는 냉장고의 배출수 응축기 입출구 배관에서의 온도 특성을 알아보고 이를 예측하는 방법을 정립하는 것을 목적으로 하였다. 이를 위해서 빌트인 냉장고를 항온항습챔버에서 운전하면서 배출수 응축기 입출구 배관에서 온도를 측정하였다. 본 연구의 실험을 통하여 측정된 온도는 $37^{\circ}C$에서 $46^{\circ}C$로 변하는데 실제 온도는 측정된 온도 보다 $8^{\circ}C$에서 $22^{\circ}C$ 만큼 크게 차이나는 것을 확인할 수 있었다. 본 연구에서는 이렇게 차이가 나는 원인을 파악하였으며 이는 배출수 응축기 입출구 배관이 냉장고 본체에 부착되어 이를 통한 열손실이 크기 때문임을 알았으며 측정된 온도 결과로부터 입출구 배관의 온도를 예측할 수 있는 방법을 제안하였다. 본 연구의 온도 계산 결과는 실제 냉매온도를 6% 오차범위의 정확도로 예측할 수 있음을 알았다.

임의의 모드를 가지는 모드적합법을 사용한 원형 단순확장관의 음향해석 (Acoustic Analysis of Simple Expansion Chamber Using Mode Matching Method with Arbitrary Number of Modes)

  • 김봉준;정의봉;이정환
    • 한국음향학회지
    • /
    • 제19권1호
    • /
    • pp.54-60
    • /
    • 2000
  • 고차모드를 고려하여 단순확장관을 해석한 많은 선행연구가 이루어 졌고, 이러한 연구는 모드적합법, 속도포텐셜법, 유한요소법으로 분류할 수 있다. 이들 중 모드적합법은 동심관형확장관을 해석하는 데 유용하다. 일반적으로 입·출구의 단면적이 중간확장관의 단면적보다 작으므로 입·출구에 고려하는 고차모드의 개수는 중간확장관에 고려하는 고차모드의 개수보다 작을 수 있다. 그러나 모드적합법은 입·출구와 중간확장관에 같은 개수의 고차모드를 사용하여야 한다. 그래서 입·출구에 불필요한 고차모드를 포함하게 되어 계산시간을 늘이는 결과를 초래한다. 본 논문에서는 입구, 중간확장관 그리고 출구에 각각 임의의 고차모드의 개수를 선택할 수 있는 새로운 방법을 제시하였다. 그리고 이 방법의 정확성을 검증하기 위하여 전통적인 모드적합법, 유한요소법과 비교하였고, 이 새로운 방법이 계산시간을 줄일 수 있다는 것을 보였다.

  • PDF

Numerical study of fluid behavior on protruding shapes within the inlet part of pressurized membrane module using computational fluid dynamics

  • Choi, Changkyoo;Lee, Chulmin;Park, No-Suk;Kim, In S.
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.498-505
    • /
    • 2020
  • This study analyzes the velocity and pressure incurred by protruding shapes installed within the inlet part of a pressurized membrane module during operation to determine the fluid flow distribution. In this paper, to find the flow distribution within a module, it investigates the velocity and pressure values at cross-sectional and outlet planes, and 9 sections classified on outlet plane using computational fluid dynamics. From the Reynolds number (Re), the fluid flow was estimated to be turbulent when the Re exceeded 4,000. In the vertical cross-sectional plane, shape 4 and 6 (round-type protrusion) showed the relatively high velocity of 0.535 m/s and 0.558 m/s, respectively, indicating a uniform flow distribution. From the velocity and pressure at the outlet, shape 4 also displayed a relatively uniform fluid velocity and pressure, indicating that fluid from the inlet rapidly and uniformly reached the outlet, however, from detailed data of velocity, pressure and flowrate obtained from 9 sections at the outlet, shape 6 revealed the low standard deviations for each section. Therefore, shape 6 was deemed to induce the ideal flow, since it maintained a uniform pressure, velocity and flowrate distribution.

인공지반을 적용한 사교하는 사면에서의 터널 갱구부 설계 (The design of outlet in inter-cross slope with tunnel which it applied forming artificial ground)

  • 박철숙;곽한;이규탁;김봉재;윤용진;김희광
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1532-1548
    • /
    • 2008
  • The tunnel type spillways is under construction to increasing water reservoir capacity in Dae-am dam. The tunnel outlet was planned to be made after installing slope stabilization system on natural slope there. Generally, the tunnel outlet is made perpendicularly to the slope, but in this case, it had to be made obliquely to the slope for not interrupting flow of river. Because of excavation in condition of natural slope caused to deflecting earth pressure, the outlet couldn't be made. So, artificial ground made with concrete that it was constructed in the outside of tunnel for producing the arching effect which enables to make a outlet. We were planned tunnel excavation was carried out after artificial ground made. Artificial ground made by poor mix concrete of which it was planned that the thickness was at least 3.0m height from outside of tunnel lining and 30cm of height per pouring. Spreading and compaction was planned utilized weight of 15 ton roller machine. In order to access of working truck, slope of artificial ground was designed 1:1.0 and applied 2% slope in upper pert of it for easily drainage of water. In addition to, upper pert of artificial ground was covered with soil, because of impaction of rock fall from upper slope was made minimum. The tunnel excavation of the artificial ground was designed application with special blasting method that it was Super Wedge and control blasting utilized with pre-percussion hole.

  • PDF

사물 인터넷 기반의 1인 가구를 위한 스마트 콘센트 시스템 (Smart Outlet System for Single-person Household based on IoT (Internet of Things))

  • 김희숙;박병주;조영주
    • 디지털콘텐츠학회 논문지
    • /
    • 제18권5호
    • /
    • pp.895-904
    • /
    • 2017
  • 본 논문에서는 1인 가구를 대상으로 전기 안전, 전기 에너지 소비 관리 그리고 비상시 네트워크를 연결하여 예약된 연락처에 메시지를 전송하는 사물인터넷 기반의 스마트 콘센트 시스템 구축 방식을 제안한다. 제안된 스마트 콘센트 시스템은 서버와 모듈, 어플리케이션, WiFi AP 수신기 사이에 패킷 데이터와 프로토콜을 파싱하여 구현된다. 통신을 위해 구축된 WiFi AP는 콘센트 뿐 만 아니라 가스 차단, 도어락 등에 연결하여 사용하는 것이 가능하다. 또한 제안된 방식은 AC 전류센서(SCT-013)를 통해 받아온 해당 콘센트의 전력량을 실시간으로 수신하여 원격 모니터링 기능을 제공할 수 있다. 스마트 콘센트 시스템은 대기전력 차단 기능과 더불어 전력 사용 자동 분석을 통해 비상시 전력 자동 차단 기능까지 할 수 있을 것으로 기대한다.

Simulation of Water Flows in Multiple Columns with Small Outlets

  • Suh Yong-Kweon;Li Zi Lu;Jeong Jong-Hyun;Lee Jun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제20권10호
    • /
    • pp.1765-1772
    • /
    • 2006
  • High-pressure die casting such as thixocasting and rheocasting is an effective process in the manufacturing automotive parts. Following the recent trend in the automotive manufacturing technologies, the product design subject to the die casting becomes more and more complex. Simultaneously the injection speed is also designed to be very high to establish a short cycletime. Thus, the requirement of the die design becomes more demanding than ever before. In some cases the product's shape can have multiple slender manifolds. In such cases, design of the inlet and outlet parts of the die is very important in the whole manufacturing process. The main issues required for the qualified products are to attain gentle and uniform flow of the molten liquid within the passages of the die. To satisfy such issues, the inlet cylinder ('bed cylinder' in this paper) must be as large as possible and simultaneously the outlet opening at the end of each passage must be as small as possible. However these in turn obviously bring additional manufacturing costs caused by re-melting of the bed cylinder and increased power due to the small outlet-openings. The purpose of this paper is to develop effective simulation methods of calculation for fluid flows in multiple columns, which mimic the actual complex design, and to get some useful information which can give some contributions to the die-casting industry. We have used a commercial code CFX in the numerical simulation. The primary parameter involved is the size of the bed cylinder. We will show how the very small opening of the outlet can be treated with the aid of the porous model provided in the code. To check the validity of the numerical results we have also conducted a simple experiment by using water.

Z-Wave 메쉬 네트워크 기반의 전기 자판기 개발 (Development of Vending Machine for Electricity Based on Z-Wave Mesh Network)

  • 강기범;안현권;김한수;이승현;좌정우
    • 한국통신학회논문지
    • /
    • 제41권10호
    • /
    • pp.1256-1262
    • /
    • 2016
  • 캠핑 인구가 증가하면서 야영장과 오토캠핑장에서 이용자에게 다양한 전기 요금 정책으로 안전하게 전기를 공급할 수 있는 전기 설비가 필요하게 되었다. 본 논문은 Z-Wave 개인무선네트워크와 안드로이드 모바일 앱을 이용하여 캠핑장의 관리서버에서 옥외 콘센트 함을 제어할 수 있는 전기 자판기를 개발한다. 개발한 전기 자판기는 관리서버, 제어기, 옥외 콘센트 함, 모바일 앱으로 구성된다. 관리서버는 제어기를 통해 콘센트 함의 스위치를 제어하여 사용자에게 안전하게 전기를 공급한다. 제어기는 관리서버와 스위치 간 중계 장치로 Z-Wave 메쉬 네트워크를 기반으로 스위치들을 제어한다. 옥외 콘센트 함은 2개의 미터 스위치를 갖는다. 옥외 콘센트 함은 캠핑장에서 상용 전기 서비스를 제공하기 위해 관련 인증을 받았다.

Analysis of Thermal Characteristics and Insulation Resistance Based on the Installation Year and Accelerated Test by Electrical Socket Outlets

  • Kim, Kyung Chun;Kim, Doo Hyun;Kim, Sung Chul;Kim, Jae Ho
    • Safety and Health at Work
    • /
    • 제11권4호
    • /
    • pp.405-417
    • /
    • 2020
  • Background: Electrical socket outlets are used continuously until a failure occurs because they have no indication of manufacturing date or exchange specifications. For this reason, 659 electrical fires related to electrical socket outlets broke out in the Republic of Korea at 2018 only, an increase year on year. To reduce electrical fires from electrical socket outlets, it is necessary to perform an accelerated test and analyze the thermal, insulation resistance, and material properties of electrical socket outlets by installation years. Methods: Thermal characteristics were investigated by measured the temperature increase of electrical socket outlets classified according to year with variation of the current level. Insulation resistance characteristics was measured according to temperature for an electrical socket outlets by their years of use. Finally, to investigate the thermal and insulation resistance characteristics in relation to outlet aging, this study analyzed electrical socket outlets' conductor surface and content, insulator weight, and thermal deformation temperature. Results: Analysis showed, regarding the thermal characteristics, that electrical socket outlet temperature rose when the current value increased. Moreover, the longer the time that had elapsed since an accelerated test and installation, the higher the electrical socket outlet temperature was. With respect to the insulation resistance properties, the accelerated test (30 years) showed that insulation resistance decreased from 110 ℃. In relation to the installation year (30 years), insulation resistance decreased from 70 ℃, which is as much as 40 ℃ lower than the result found by the accelerated test. Regarding the material properties, the longer the elapsed time since installation, the rougher the surface of conductor contact point was, and cracks increased. Conclusion: The 30-year-old electrical socket outlet exceeded the allowable temperature which is 65 ℃ of the electrical contacts at 10 A, and the insulation resistance began to decrease at 70 ℃. It is necessary to manage electrical socket outlets that have been installed for a long time.