Effects of Water Amount in Refrigerant on Cooling Performance of Vehicle Air Conditioner  

Moon, Seong-Won (Dept. of Bio-Industrial Machinery Eng., Gyeongsang Nat'l Univ. (Insti. of Agric. & Life Sci.))
Min, Young-Bong (Dept. of Bio-Industrial Machinery Eng., Gyeongsang Nat'l Univ. (Insti. of Agric. & Life Sci.))
Chung, Tae-Sang (Dept. of Mechanical Engineering, Gyeongnam National University of Science and Technology)
Publication Information
Journal of Biosystems Engineering / v.36, no.5, 2011 , pp. 319-325 More about this Journal
Abstract
This study was conducted to figure out the diagnosis basis of cooling performance depending on water amount in the refrigerant of air conditioner, which can be estimated by the temperatures and pressures along the refrigerant circulation line. A car air conditioner of SONATA III (Hyundai motor Co., Korea) was tested at maximum cooling condition at the engine speed of 1500 rpm in the room controlled at 33~$35^{\circ}C$ air temperature and 55~57% relative humidity conditionally. Measured variables were temperature differences between inlet and outlet pipe surfaces of the compressor, condenser, receive drier and evaporator; and high pressure and low pressure in the refrigerant circulation line; and temperature difference between inlet and outlet air of the cooling vent of evaporator. In this study, changes of the water amount in the refrigerant were correlated to the temperatures and pressure changes and also water amount caused poor cooling performance. As water amount increased in the refrigerant in the air conditioner, the performance of the cooling or the heat transfer became worse. Temporal variations of the surface temperature of the evaporator outlet pipe and the low-side pressure showed various patterns that could estimate the water amount. When the water amount caused bad cooling performance, the patterns of the temperature of the evaporator outlet pipe indicated irregular fluctuation greater than $5^{\circ}C$. When the diagnosis system is using just external sensors of the low-side pressure and the temperatures of inlet and outlet air of cooling vent of the evaporator, the precise pattern of bad cooling performance caused by excess water amount in the cooling line was irregular pressure fluctuation, 25 kPa under 120 kPa, and temperature, $12^{\circ}C$ and less.
Keywords
Air conditioner; Refrigerant charge; Diagnosis of air conditioner;
Citations & Related Records
Times Cited By KSCI : 6  (Citation Analysis)
연도 인용수 순위
1 Lee, G. H., J. D. Jung, K. H. Choi and J. Y. Yoo. 1998. An experimental study on the performance of automobile air conditioning system with variations of charging conditions. Transactions of Korea Society of Automotive Engineers 6(2):203-211. (In Korean)   과학기술학회마을
2 Moon S. D., Y. B. Min, S. W. Moon, D. H. Kang and T. S. Chung. 2008. Effect of refrigerant charging variation on temperature and pressures of refrigerant circulation line for air conditioner. Journal of Agriculture and Life Science in Gyeongsang National University 42(3) : 29-34. (In Korean)
3 Moon. S. W., Y. B. Min, and T. S. Chung. 2009. Cooling Performance Deficiency of Air Conditioning System According to Air Quantity Included in Refrigerant. Journal of Biosystems Engineering 34(6):470-475. (In Korean)   과학기술학회마을   DOI
4 Suh, E. K. and O. N. Ha. 2003. Performance characteristics of heat exchanger for the automobile air-conditioner. Journal of Research Institute of Energy and Resources Technology 25(2):119-133. (In Korean)
5 Kang, G. C., Y. J. Kim, Y. S. Ryou and Y. Paek. 2002. Development of heating and cooling system with heat pump for nutrient solution bed in greenhouse. Journal of the Korean Society for Agricultural Machinery 27(6):565-572. (In Korean)   과학기술학회마을   DOI
6 Kang, Y. K., C. S. Han and D. H. Keum. 2007. Drying and low temperature storage system for agricultural products using the air to air heat pump (1) - drying performance -. Journal of Biosystems Engineering 32(1):20-29. (In Korean)   과학기술학회마을   DOI
7 Kim, C. W. 2005. Automotive Air Conditioner. pp.199-214. Joongwonsa, Seoul, Republic of Korea, (In Korean)
8 Kwon, K. H., J. W. Jeong, J. H. Kim and C. H. Choi. 2006. Development of cold chain system using thermal storage with low-energy type. Journal of Biosystems Engineering 31(3): 161-167. (In Korean)   과학기술학회마을   DOI