• Title/Summary/Keyword: Outdoor Insulation

Search Result 137, Processing Time 0.031 seconds

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers

  • Jang, Sang Sik;Lee, Hyoung Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.47 no.4
    • /
    • pp.533-542
    • /
    • 2019
  • As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.

Thermal Characteristics Analysis by Ambient and Operating Temperature according to the Kinds of Terminations in Underground Power Cable Systems (지중송전케이블 종단접속함 종류에 따른 외기 및 운전온도에 의한 열특성 분석)

  • Jung, Chae-Kyun;Kang, Ji-Won;Lee, Bang-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.8
    • /
    • pp.1154-1160
    • /
    • 2015
  • This paper describes the thermal characteristics of underground power cable system terminations according to the change of ambient temperature as well as operating temperature. Recently, the failure has been gradually increasing in outdoor termination during winter season because the power demand was increased by electricity heating system. The power demand and outdoor temperature is difference between day time and night time. The temperature difference has an influence on conductor extension and shrinkage due to conductor force as well as thermal mechanical characteristics. These phenomena have daily repeated during heating and cooling period of conductors. In these cases, the insulation of outdoor terminations might be degraded by the reduced interface pressure surrounding stress relief cone. Therefore, in this paper, the thermal characteristics are variously analysed by simulation considering power demand and ambient temperature condition during winter season at epoxy type termination as well as slip-on type termination

Properties of Surface Electrical Conduction in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도특성)

  • 박영국;강성화;정수현;이운석;임기조
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.207-210
    • /
    • 1998
  • Surface electrical conduction in insulator is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the widely used materials for outdoor insulator - porcelain, EPDM, Silicone rubber - were discussed by measuring properties of average leakage current and scintillation discharge pulses under artificial contamination conditions. The artificial contaminations used were deionized distilled water fog, 0.5wt% NaCl salt fog of light pollution and 2wt% NaCl salt fog of medium pollution. The average leakage current was appeared linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage was most different to that in case of dry and clean condition. In case of salt fog pollution condition. The leakage current was increased above critical voltage. The scintillation discharges were also activated at the level the leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

Electrical Conduction Properties of Surface in Materials for Outdoor Insulator (옥외 애자용 재료의 표면 전기전도 특성)

  • 박영국;이운석;정수현;장동욱;임기조
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.10
    • /
    • pp.758-762
    • /
    • 1998
  • Electrical conduction property of insulator surface is most important factor to assess the insulation performances of outdoor insulating materials. In this paper, contamination performance of the materials to be used for outdoor insulator such as porcelain, EPDM, silicone rubber was discussed by measuring properties of average leakage current and scintillation discharge pulses under salt fog conditions. The fog was applied by nozzle in chamber and fogging fluids were deionized distilled water, 0.5wt% NaCI solution and 2wt% NaCl solution. The average leakage current showed linearly with applied voltage at dry and clean surface condition. The magnitude of leakage current was almost same at different kinds of samples. In case of deionized distilled water fog, the characteristics of leakage current and applied voltage were much different to those in case of dry and clean condition with 2wt% salt fog. In case of slat fog pollution condition, the leakage current was increased above critical voltage. the scintillation discharges were also activated at the level. The leakage current and scintillation discharges were increased with increasing pollution degree. The resistance to pollution properties of silicone rubber appeared excellent among them.

  • PDF

A Study on Optimization of Thermophysiological Indices for Harbor Workers in Summer: Improvement of MENEX Model's Input Data Considering the Work Environment (하계 항만열환경지수 최적화 방안연구: 항만작업환경을 반영한 MENEX모델의 입력변수 개선)

  • Yun, Jinah;Hwang, Mi-Kyoung;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.25 no.7
    • /
    • pp.951-961
    • /
    • 2016
  • To prevent increasing instances of heat-related illnesses due to heat waves generated by climate change, a customized thermal environment index should be developed for outdoor workers. In this study, we conducted sensitivity analysis of the Masan harbor during a heat wave period (August 9th to 15th, 2013) using the MENEX model with metabolic rate and clothing-insulation data, in order to obtain realistic information about the thermal environment. This study shows that accurate input data are essential to gather information for thermophysiological indices (PST, DhR, and OhR). PST is sensitive to clothing insulation as a function of clothing. OhR is more sensitive to clothing insulation during the day and to the metabolic rate at night. From these results, it appears that when exposed to high-temperature thermal environments in summer, wearing highly insulated clothing and getting enough rest (to lower the metabolic rate) can aid in preventing heat-related illnesses. Moreover, in the case of high-intensity harbor work, quantification of allowed working time (OhR) during heat waves is significant for human health sciences.

The Electric Field Distribution Characteristic Of Outdoor ECT Using the Preventive Diagnostic Sensor (예방진단센서가 내장된 옥외용 ECT의 전계분포특성)

  • Lee, Han-Joo;Cho, Sung-Hoon;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joo;Kang, Sung-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.03b
    • /
    • pp.27-27
    • /
    • 2010
  • The exact partial discharge pulse should be measured in order to estimate the discharge source in the solid insulation and diagnose the degree of deterioration. Partial discharges generated in the insulation occur in the internal voids or at the edge of the insulation, have unique characteristics following the type and location. When external voltage is applied, Partial discharges occurred in the restrictively presented voids increase the quantity of electrical charge at the discharge onset voltage. The discharge characteristics have remained constant as space is filled by the impurity such as a compound of gases accompanied with discharge. In this study, How to design the insulation about the problems of the built-in diagnostics in the transformer is discussed by the interpretation of electric field.

  • PDF

Field Test of Tunnel Lining Temperature Variation Using Insulation Material (단열재를 활용한 터널라이닝 온도변화 현장 실험)

  • Jin, Hyunwoo;Hwang, Youngcheol
    • Journal of the Korean GEO-environmental Society
    • /
    • v.20 no.4
    • /
    • pp.11-16
    • /
    • 2019
  • The low temperature and temperature difference (variation) may cause to deteriorate the integrity of tunnel constructed in cold region. An insulation material was developed and applied to the tunnel lining surface to keep the temperature of tunnel lining constant in spite of temperature variation at outdoor. The lining surface where the insulation material applied showed the less sensitive to temperature variation than non-applied lining surface.

IAQ improvement effect analysis in Dynamic Breathing Building(DBB) (숨쉬는 벽체를 적용한 건물에서의 실내공기질(IAQ) 개선 효과 분석)

  • Park, Yong-Dai;Lee, Jin-Sook;Kang, Eun-Chul;Lee, Euy-Joon
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.748-753
    • /
    • 2008
  • In modern buildings, the air-tightness and insulation for energy saving resulted in degradation of Indoor Air Quality(IAQ). It has brought out new diseases such as New Building Syndrome(NBS) and Sick Building Syndrome(SBS) to the tenants of such buildings. As a result, researches on the Dynamic Breathing Building(DBB) are being undertaken to minimize energy loss as well as to improve IAQ. DBB is a state-of-the-art technology to build channels inside the wall so that air migrates between indoor and outdoor, which improves insulation performance and IAQ. This study attempts to evaluate the improvement of DBB employed in real buildings. As analyzing tools, IAQ improvement and particle degradation while were evaluated while the required indoor ventilation rate was satisfied. DBB were installed in the twin test cells at Korea Institute of Energy Research(KIER). From the test, IAQ was compared with outdoor air base on the concentration of particle matter(PM10). As a results, the concentration of particle dust (PM10) within the breathing walls was reduced by 80% at 0.7 ACH, 67% at 2 ACH, 63% at 3 ACH respectively. As ACH is higher, Dnamic Isulation(DI) and normal wall permit more PM10 particles being infiltrated.

  • PDF

A Study on Recognition and Preference of Functional Textile Material of Outdoor Clothing by Age (아웃도어 웨어 기능성 소재에 대한 연령별 인지 및 선호도)

  • Seo, Min Nyoung;Kim, A Hyun;Koo, Young Seok
    • Fashion & Textile Research Journal
    • /
    • v.18 no.2
    • /
    • pp.184-193
    • /
    • 2016
  • This study investigates the recognition and preference of functional textile material about outdoor clothing widely used in the current fashion market. The study targeted 216 males and females in their 20s to 50s who wear outdoor clothing as casual wear. To analyze data, frequency analysis, cross tabulation analysis and ANOVA were conducted with the SPSS 21.0 statistical package. The results are as follows. First, recognition of functional textile material of outdoor clothing showed that 20s was the lowest preference and all age groups preferred lightweight textile material. In information recognition of functional outdoor clothing, 40s showed the highest recognition, while 20s showed the lowest recognition. Second, 40s and 50s preferred functional material to 20s and 30s. In particular, 40s and 50s preferred clothing items with water vapor permeability & water repellent material to 20s and 30s. All age groups preferred insulation material jumpers, water vapor permeability & water repellent material jumpers and stretch pants. Third, reasons for purchasing functional material clothing was: design for the age group 20s and 30s versus health and function for the age group 40s and 50s. It is necessary to develop functional clothing products based on exact consumer information and preferences.

Investigation of Recovery Characteristic in Silicone Rubber Used for Outdoor Insulation by Measuring Leakage Current (누설전류 측정을 통한 옥외용 실리콘 절연재의 회복특성)

  • Huh, Chang-Su;Youn, Bok-Hee;Lee, Sang-Youb;Lee, Jong-Han
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1605-1607
    • /
    • 1999
  • Silicone rubber have presently been using in large number for a variety of outdoor HV applications. Silicone rubber have the properties of low surface energy and are able to retain its hydrophobicity or water repellency, thereby suppress the leakage current in the present of moisture and contamination. In this paper, we investigated the recovery characteristics of silicone rubber by measuring the leakage current under salt-fog.

  • PDF