Browse > Article
http://dx.doi.org/10.5658/WOOD.2019.47.4.533

Thermal Resistance and Condensation in the Light-frame Timber Wall Structures with Various Composition of Insulation Layers  

Jang, Sang Sik (Department of Bio-based Materials, College of Agriculture & Life Sciences, Chungnam National University)
Lee, Hyoung Woo (Department of Bio-based Materials, College of Agriculture & Life Sciences, Chungnam National University)
Publication Information
Journal of the Korean Wood Science and Technology / v.47, no.4, 2019 , pp. 533-542 More about this Journal
Abstract
As energy costs increase, more people has become interested on energy efficiency and savings in residential buildings. The two main subjects related to energy in residential buildings are insulation and condensation. There are two approaches to prevent condensation; increasing air tightness and maintaining the temperature inside of the wall structure over the dew point, which is in turn related to insulation. Even though the Korean government has highlighted the importance of energy efficiency for residential housings, and in spite of the customers' demands, the timber construction industry is still using conventional light-frame construction without even trying to improve energy efficiency. In this study, various types and combinations of wall structures were tested under cold outdoor and warm indoor temperatures to analyse the temperature gradients and to determine the possible sites of condensation in the wall structures. In addition to the experimental tests, three theoretical models were developed and their estimations of temperature change through the wall structure were compared with the actual measurements to evaluate accuracy of the models. The results of the three models agree relatively well with the experimental values, indicating that they can be used to estimate temperature changes in wall structures. The theoretical analysis of different insulation layers' combinations show that condensation may occur within the mid-layer in the conventional light-frame wall structures for any combination of inner-, mid-, and outer-layers of insulation. Therefore, it can be concluded that the addition of an inner and outer insulation layer or increasing the thickness of insulation may not be adequate to prevent condensation in the wall structure without preventing penetration of warm moist air into the wall structure.
Keywords
energy efficiency; insulation; thermal resistance; light-frame timber construction; temperature change coefficient;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Seo, J., Wi, S., Kim, S. 2016. Evaluation and analysis of the building energy saving performance by component of wood products using Energy Plus. Journal of the Korean Wood Science and Technology 44(5): 655-663.   DOI
2 Yu, S.G., Kim, S., Seo, J., Kim S. 2013. Analysis of energy efficiency of light-weight wood frame house and wooden passive house using PHPP. Journal of the Architectural Institute of Korea 29(8): 199-207.
3 Kang, W., Chung, W.Y., Lee, H.W., Lee, Y.H., Song, J.G. 2007. Construction physics. Chunnam National University, Kwangju, Korea.
4 Kang, Y., Kim, S. 2016. Evaluation of the hygrothermal performance by wall layer component of wooden houses using WUFI simulation program. Journal of the Korean Wood Science and Technology 44(1): 75-84.   DOI
5 Kim, Y.H. 2013. Evaluation and prediction of thermal performance for exterior wall systems of timberframed houses. Ph.D. Dissertation of Chungnam National University, Daejeon, Korea.
6 Kim, Y.H., Jang, S.S., Shin, I.J. 2011. Heat transfer of green timber wall panels. CNU Journal of Agricultural Science 38(1): 115-120.
7 Seo, J., Jeong, S.G., Kim, S. 2017. Thermal bridge and heat transfer analysis for each part in residential building according to construction of wood-based finishing material. Journal of the Korean Wood Science and Technology 45(3): 343-359.   DOI