• 제목/요약/키워드: Outdoor(rooftop)

검색결과 22건 처리시간 0.028초

빗물 유출면 및 빗물 침투시설이 주거단지 유출빗물의 pH에 미치는 영향 (The Effect of Impermeable Surface and Rainwater Infiltration Facilities on the Runoff pH of Housing Complexes)

  • 현경학;최정주;정연규
    • 환경영향평가
    • /
    • 제19권1호
    • /
    • pp.39-47
    • /
    • 2010
  • In order to examine the effect of impermeable surface (rooftop, outdoor parking lot) and rainwater infiltration facilities on runoff pH, pH was measured. pH measurement spots were splash blocks accepted roof runoff of 3 sites, infiltration boxes and trenches accepted parking lot runoff and plastic rainwater harvesting facility accepted roof runoff. These measurements were operated at 3 housing complexes from 2006 to 2009. The rainwater runoff pH was influenced by the quality of the runoff surface material (concrete), the age of the building, waterproofing methods according to each housing site, antecedent rainfall conditions and others. Rain garden, infiltration boxes and trenches decreased the alkalinity of runoff by detention and infiltrating the roof and outdoor parking lot runoff. These results mean that decentralized rainwater management facilities of housing complexes can reduce effect on the outskirt aquatic ecosystem by the accumulation of substances causing pH rising in the infiltration facilities and rain garden.

열환경 완화를 통한 주택지내 쾌적성 확보에 관한 연구 (A Study on Thermal Comfortable Following the Thermal Environment Migration in Detached Housing Area)

  • 류지원;정응호;호야노 아키라;김대욱
    • 한국주거학회논문집
    • /
    • 제24권1호
    • /
    • pp.51-59
    • /
    • 2013
  • This study aims to improve the thermal comfort level of detached housing area by reducing the impact of thermal environment. The study focused on reducing surface temperature that is generated in buildings and adjacent spaces as a result of sensible heat load and presented a proposal on implementing planting method considering its outdoor condition and structure and composed materials. To perform the study, we utilized 3D-CAD to examine the outdoor condition and structure and composed materials that impact on surface temperature and conducted space design after reflecting climatic elements in simulations. The result is as follows. In reviewing temperature distribution of Heat Island Potential (HIP) of buildings and adjacent spaces, in case where green coverage ratio is increased, there was a $6^{\circ}C$ temperature difference and in regard to changes in the thermal environment in detached housing area, in case where rooftop planting, surface improvement, planting, and overall green coverage ratio is increased, there was a $10^{\circ}C$ temperature difference. In addition, there was difference in temperature in detached housing area following the changes in wind.

대학 캠퍼스 건물 내부휴게공간의 공간적 특성에 관한 연구 (A Study on Spatial Characteristics of Indoor Rest Zones in the Campus Buildings)

  • 박준수;김성아;서기영;박창희;이성창
    • 교육시설
    • /
    • 제10권3호
    • /
    • pp.37-43
    • /
    • 2003
  • This study investigates the physical characteristics of indoor rest zones using the Space Syntax Method. A conceptual framework is based on analysis of design works presented in competitions(544 rest zones of 24 buildings on 7 campuses). The analysis on the unit type of rest zones showed that they were mostly available as open type, followed by semi-open type and outdoor rest places. On the other hand, by classifying the shape of whole building into traffic lines and nodal points, it was found that the buildings with 3 or more traffic lines have lower availability than others, because the buildings required more nodal points along a little higher complexity and zoning formed at increased nodal points between building masses. The analysis on the location of rest zones on traffic lines showed that hall type was most excellent in the level of availability. Finally, the analysis on the floor height showed that hall-like open rest places and outdoor places like rooftop garden functioned as a factor to enhance the integration of different spaces. In conclusion, this research will help the follow-up studies make spatial creation planning that may enhance the spatial efficiency and availability of Indoor rest zones on the campus.

초고층 공동주택의 입상덕트 환기시스템에서 외기조건과 작동조건에 따른 환기성능평가 (Ventilation Performance According to Outdoor and Operating Conditions of the Vertical Exhaust Duct System in High Riser Public Houses)

  • 김영배;김재홍;성재용;이명호
    • 설비공학논문집
    • /
    • 제23권2호
    • /
    • pp.139-146
    • /
    • 2011
  • The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.

쿨루프 적용에 따른 업무용 건물의 내·외부 온도 저감 효과 (Reduction in Indoor and Outdoor Temperature of Office Building with Cool Roof)

  • 송봉근;김경아;박경훈
    • KIEAE Journal
    • /
    • 제16권6호
    • /
    • pp.95-101
    • /
    • 2016
  • Purpose: This study aims to identify the effect of temperature reduction by the application of cool roof coatings to Changwon City Hall in South Gyeongsang Province. The indoor and outdoor temperatures of the cool roofing building were analyzed and compared to that of an existing building with green-colored roof coated with waterproof polyurethane. Method: The surface temperatures and reflectivity of rooftops, surface temperatures of ceilings and the interior, and outdoor temperature and humidity of the two aforementioned buildings were measured from June to September in 2014. The measurements were taken every 10 min. Result: The surface temperature of the building with the cool roof was lower by a maximum of $9^{\circ}C$ with the reflectivity of the rooftop at an average of 0.55, which is higher than that of the building with green polyurethane by approximately 0.3. The temperature of the ceiling inside the building with the cool roof was about $1{\sim}2^{\circ}C$ lower than that of the ordinary building. Also, the indoor temperature of the office with cool roof coatings was about $0.5{\sim}1.0^{\circ}C$ lower than that of the office with green-colored roofing building. The results show that cool roof coatings can lower the temperature of buildings. In the next research, the reduction in consumption of energy for air conditioning will be investigated by utilizing building energy simulation tools.

방수시트의 평행접합방법에 따른 인장성능 평가연구 (A Study on the Evaluation of Tensile Performance According to Pareral Jointing Methods of the Sheet Membrane Waterproofing System)

  • 이정윤;오미현;곽규성;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2004년도 학술대회지
    • /
    • pp.39-44
    • /
    • 2004
  • A heat and room temperature construction method of asphalt have been mainly applying to rooftop waterproofing in concrete structure, and the rest construction method are sheet, membrane and mortar waterproofing construction method. In particular, joint method in sheet waterproof method is as overlap joint which on being reinforced with fiber and tape, have been applying for job site to mechanical fix using protection disk and anchorage and metal ironwork on the end of sheet. These construction method cause cutting off joint of sheet as behavior of structure according to repairs of sheet itself and thermal conduct, outdoor air environment. In conclusion, we analyzed and examined the application of various sheets and piece ashes about superior 'I' joint which divide from one and the other sheet and progressed about joint construction method of fixing method for overlap.

  • PDF

NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석 (An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101)

  • 조지은;공하성
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.331-337
    • /
    • 2020
  • 이 연구는 NFPA 101기준에 의한 대상아파트인 27층 아파트에서 한 세대 당 적정 수용인원 수를 피난시뮬레이션을 통해 분석하였다. 분석결과는 다음과 같다. 첫째, 한 세대당 3명이 거주하는 경우 아파트 총 세대수는 156명이고 5분 이내에 대피인원을 확인 한 결과 85.25%가 대피한 것으로 나타났다. 둘째, 한 세대당 4명이 거주하는 경우 아파트 총 세대수는 208명이고 5분 이내에 대피인원을 확인한 결과 81.25%가 대피한 것으로 나타났다. 셋째, 한 세대당 5명이 거주하는 경우 아파트 총 세대수는 260명이고 5분 이내에 대피인원을 확인한 결과 71.92%가 대피한 것으로 나타났다. 마지막으로 한 세대당 6명이 거주하는 경우 아파트 총 세대수는 312명이고 5분 이내에 대피인원을 확인한 결과 62.82%가 대피한 것으로 나타났다. 피난시간의 단축방안으로 실내인원 수, 건물 층수, 계단 경사도, 사용자의 특성에 따른 계단 폭의 결정, 계단 환기조건을 반영한 설계, 옥외피난계단, 양방향 계단, 피난용 승강기, 층 중간에 건물외부로 대피할 수 있는 피난안전구역 등의 설치, 옥상에 비상문 자동개폐장치의 의무설치로 인한 옥상대피를 용이하게 하는 등의 방안이 필요하다.

태양의 위치에 따른 광파이프 시스템의 실내 주광환경평가 (Assessment of Daylight Environment on Light Pipe System Under Different Solar Position)

  • 신화영;김정태
    • 한국태양에너지학회 논문집
    • /
    • 제28권6호
    • /
    • pp.78-86
    • /
    • 2008
  • The aim of this paper is to show the daylight environment of a light pipe system according to sun movement. A light pipe system has been mounted on the roof of the windowless full scale model: the solar spot has diameter of 0.65m and is 1.3m long, giving an aspect ratio of 1:2. The full scale model was installed on the rooftop of the SHINAN apartment in Yongin city that has no obstructions against sunlight. The test room is equipped with sensors for the measurements of the internal illuminance and has an area of 6m(W)$\times$6m(D)$\times$4m(H). The system has been monitored with a data-logger to evaluate the cumulative distribution of illuminance on a floor-plane from 16th, April to 29th, May, 2008 over one month and selected clear sky condition. For the daylight performance of floor area, the totally 49 measuring points has been used to determine the internal illuminance and an HP datalogger(HP34970A) records the measurements for one consecutive month. The horizontal external illuminance has been measured with two outdoor sensors. This paper presents the results of monitoring light pipe system with internal/external illuminance ratio and cumulative frequency distribution of floor-plane illuminance are discussed The results show that lightpipe is proficient device for introducing daylight into the building. However It provided different daylight indoor environment with wide or narrow Interquatile range of illuminance, internal/external illuminance ratio and cumulative frequency distribution according to solar positions under suuny sky condition. For more achieving the improvement of lightpipes also include energy savings, user visual comfort with various indicators; seasonal solar height, room and lightpipes geometries.

24절기 야외 부유곰팡이 농도 조사 및 기상요소와의 상관성 분석 (Survey of Airborne Fungi Levels in 24 Seasonal Divisions and Correlation Analysis with Meteorological Elements)

  • 김명남;홍진영;이정민;박지희
    • 보존과학회지
    • /
    • 제35권6호
    • /
    • pp.652-663
    • /
    • 2019
  • 목조건축문화재의 생물피해 영향을 미치는 야외 부유곰팡이의 연중 변화와 일간 변화를 파악하기 위해서는 포집주기와 측정시간대의 충분한 반영이 필요하다. 본 연구는 2018년 8월부터 2019년 7월까지 1년간 국립문화재연구소 보존과학센터 옥상에서 에어샘플러와 Potato dextrose agar 배지를 이용하여 포집주기는 24절기, 포집시간대는 14시(낮)와 23시(밤)에 포집하였고, 기상요소를 1시간 단위로 수집하였으며, 부유곰팡이의 농도 조사 및 기상요소와의 상관성 분석을 진행하였다. 그 결과, 부유곰팡이 농도는 11월, 가을, 밤에 가장 높았고, 가을, 여름, 겨울, 봄 순으로 높았으며, 강우, 태풍, 황사/미세먼지에 따라 부유곰팡이 농도, 종류, 우점은 달랐다. 부유곰팡이 농도는 강수량, 강수일수, 상대습도와 강한 양의 선형 상관성이 나타났다. 부유곰팡이 농도는 영양원에 있어서는 죽은 식물체의 증가 시기, 기상요소에 있어서는 강우를 포함한 높은 상대습도 조건과 관련이 깊었다.

감천항 수산물 도매시장 조경설계 (Landscape Design of Gamcheon Wholesale Fish Market)

  • 권영휴;민권식;황용득
    • 한국조경학회지
    • /
    • 제30권2호
    • /
    • pp.70-78
    • /
    • 2002
  • The landscape disign of Gamcheon wholesale fish Market was designed around a turnkey base to promote the economy of Busan Metropolitan City, to establish a fishery marketing center and to modernize existing facilities. The objectives of the project were to promote the mood of an old market, while preserving its functions and efficiency as a market, to design outdoor spaces with natural resources and amenities in balance, and to create attractive tourist spots in connection with the wide area development plan. The project was oriented, fast, to enhance the functions of the market. For this purpose, a multi-dimensional space layout was designed in consideration of functions as a wholesale market. The safety of pedestrians was secured by separating lathes for vehicles and for pedestrians. Tree planting with various functions such as sheltering, wind breaking and guiding was planned. Secondly, nature-friendly and human-friendly landscaping design was attempted. For this, the beautiful natural resources of Amnam Park were utilized, and green spaces such as green bridges linking buildings in the wholesale market, and rooftop gardens were to be arranged. In addition, environment-friendly facilities such as roads paved with natural materials(i.e. gravel, shells) and program parking lots were to be planned. Thirdly, landscape design was considered to create attractive tourist spots. For example, a fish farm was created as a theme street for pedestrians and various water-friendly spaces such as pedestrian ramps, observatories and seaside streets were to be secured. The main contents are as follows. First, a green bridge to Ahnnam Park was introduced for a tour source and flower garden, an event plan and viewing deck open to the sea were planned on the bridge's axis. Secondly, for the effective land use plan concerning open space and convenience to visitors, a promenade was planned, which is connected with the theme plaza and small plazas by environmental sculptures in front of the market hall and at the gate. As well, an observatory and a roof garden help create three dimensional multi leveled space, with a good view of the natural landscape of the sea, sky and park Thirdly, landscape materials, such as trees and those for facilities, strengthened for protection against the seawind and salt damage were selected. The commercial market area was intended to be transformed a traditional functional area of efficiency and economy into an attractive marine leisure area where both tourists and neighbors can make use of it.