Abstract
The ventilation performance of a vertical exhaust duct system in the high riser public house has been evaluated by a commercial software, Fluid Flow, which solves pressure losses through the duct system including bathroom fans and a hybrid roof fan. During the numerical simulations, outdoor wind condition and stack effects in summer and winter were considered as well as the operating conditions of a basement damper and the roof fan. The results show that the bathroom ventilation in summer is the most unsatisfactory. The opening of the basement damper has a problem that the polluted air in the lower floors is exhausted to the underground parking lot, not to the rooftop. If the basement damper is closed, the exhaust flow rate in the lower floors is not sufficient due to the strong flow resistance in the long vertical duct even though the roof fan is under operating.
Keywords
Ventilation performance; Stack effect; Roof fan; Basement damper; Vertical exhaust duct;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Kwon, Y. I. and Ahn, J. H., 2009, Study on the control performance evaluation of the exhaust stack used in high-riser public house, Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 21, No. 2, pp. 103-108.
2 Kim, Y. D. and Kim, K. W., 2003, Simulation of the kitchen and bathroom exhaust systems in high-rise apartment buildings, Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 15, No. 12, pp. 996-1006.
3 Kim, J. K., 2009, Piping system fluid flow v.3, Journal of Fluid Machinery, Vol. 9, No 6, pp. 91-95.
4 Yeo, J. H., Hur, N., Won, C.-H., Kim, S. R., and Choi, C.-K., 2007, A numerical simulation of the pressure coefficient around a cubic building model, Proc. Autumn Symposium of KSCFE, pp. 162-166.
5 Tamura, G. T. and Wilson, A. G., 1967, Pressure differences caused by chimney effect in the three high buildings, ASHRAE Transactions. Vol. 73(II), pp. 1.1-1.10.
6 Tamblyn, R. T., 1991, Coping with air pressure problems in tall buildings, ASH-RAE Transactions. Vol. 97(I), pp. 824-827.
7 Jo, J. H., Yeo, M. S., Yang, I. H., and Kim, K. W., 2001, Field measurement and simulation of the stack effect in high-rise building, Proc. Architectural Institute of Korea, Vol. 21, No. 2, pp. 965-968.
8 Lee, J. H., Song, D. S., Lim, H. W., and Park, D. R., 2008, Study on stack effect characteristics by outdoor wind conditions in high-rise residential buildings, Proc. KIAEBS, pp. 106-109.
9 Lee, K. H., Kim, S. M., Park, Y. H., Moon, J. S., and Sohn, J. Y., 2005, A Study on the air tightness performance and stack effect characteristics in high-rise apartments, Proc. Architectural Institute of Korea, Vol. 21, No. 12, pp. 279-286.