• Title/Summary/Keyword: Out-of-Plane Actuator

Search Result 19, Processing Time 0.025 seconds

ACTUATION CHARACTERISTICS OF A MICROMIRROR FOR FINE-TRACKING (미세 트랙킹을 위한 마이크로미러 액튜에이터의 구동 특성)

  • Yee, Young-Joo;Bu, Jong-Uk;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1521-1527
    • /
    • 2000
  • A micromirror actuated by piezoelectric unimorph cantilevers is proposed as a tine-tracking device for high-density optical data storage. Bending motions of the metal/PZT/metal unimorphs translate an integrated micromirror along the out-of-plane vertical direction. The micromirror alters the optical path of the incident laser beam and linearly steers the reflected laser beam by its out-of-plane parallel actuation. Numerical analysis shows that the actuated micromirror can satisfy the tracking speed imposed by the requirement on the access time for the high-density optical data storage up to few tens Gbitlin2 owing to the light mass of the micromirror. In this paper, preliminary characteristics of the micro-machined PZT actuated micromirror (PAM) are reported. Only a 360 nm-thick PZT film deposited by sol-gel process shows both good electrical and mechanical characteristics for the fine-tracking actuator. The micromirror can be easily actuated up to several micrometers under low voltage operation condition well below 10 volts.

  • PDF

Direct Velocity Feedback for Tip Vibration Control of a Cantilever Beam with a Non-collocated Sensor and Actuator Pair (비동위치화된 센서와 액추에이터를 이용한 외팔보의 끝단 진동에 대한 직접속도 피드백제어)

  • Lee, Young-Sup
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.109-114
    • /
    • 2004
  • This paper presents a theoretical and experimental study of a non-collocated pair of piezopolymer PVDF sensor and piezoceramic PZT actuator, which are bonded on a cantilever beam, in order to suppress unwanted vibration at the tip of the beam. The PZT actuator patch was bonded near the clamped part and the PVDF sensor, which was triangularly shaped, was bonded on the other part of the beam. This is because the triangular PVDF sensor is known that it can detect the tip velocity of a cantilever beam. Because the arrangement of the sensor and actuator pair is not collocated and overlapped each other, the pair can avoid so called 'the in-plane coupling'. The test beam is made of aluminum with the dimension of $200\times20\times2mm$, and the two PZT5H actuators are both $20\times20\times1mm$ and bonded on the beam out-of-phase, and the PVDF sensor is $178mm\times6mm\times52{\mu}m$. Before control, the sensor-actuator frequency response function is confirmed to have a nice phase response without accumulation in a reasonable frequency range of up to 5000 Hz. Both the DVFB and displacement feedback strategies made the error signal from the tip velocity (or displacement) sensor is transmitted to a power amplifier to operate the PZT actuator (secondary source). Both the control methods attenuate the magnitude of the first two resonances in the error spectrum of about 6-7 dB.

  • PDF

The Development of High Precision Manipulator and Micro Gripper (미세 작업을 위한 마이크로-나노 로봇개발)

  • Lee, Jong-Bae;Park, Chang-Woo;Kim, Bong-Seok;Park, Jun-Sik;Sung, Ha-Gyeong
    • The Journal of Korea Robotics Society
    • /
    • v.2 no.1
    • /
    • pp.64-70
    • /
    • 2007
  • In this paper, a robotic system which consists of a precision manipulator and a micro gripper for a micro system assembly is presented. By the experiment, we proved that the developed the system gives acceptable performance when minute operations. Developed the micro-nano robot is actuated by newly proposed modular revolute and prismatic actuators. As an end-effector of this system, micro gripper is designed and fabricated with MEMS technology and the displacement of jaw is up to 142.8 micro meter. We think that new robot system will be appropriate for micro system assembly tasks and life science application.

  • PDF

Flow in a High Speed Compressor Due to Axisymmetric Tip (대칭 팁 간극에 기인한 고속으로 회전하는 압축기에서의 유동)

  • Joo, Hyun Suh;Song, Seung Jin
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.279-283
    • /
    • 2002
  • The effects of finite gap at the tip of turbomachinery blades have long been topics of both theoretical and experimental research because tip clearance degrades turbomachinery performance. This paper presents an analytical study of radial flow redistribution in a high speed compressor stage with axisymmetric tip clearance. The flow is assumed to be inviscid and compressible. The stage is modeled as an actuator disc and the analysis is carried out in the meridional plane. Upon going through the stage, the radially uniform upstream flow splits into the tip clearance and passage flows. The tip clearance flow is modeled as a jet driven by blade loading, or pressure difference between the pressure and suction sides. The model takes into consideration the detached shocks which occur in the rotor passage at the design point. This shock model is used to calculate the density ratio across the stage. Thus, the model is capable of predicting the kinematic effects of tip clearance in the high speed compressor flow field.

  • PDF

Fabrication of a Magnetostrictive Transpositioner using Thin Film Deposition and MEMS Techniques (박막성형 기술 및 MEMS 공정을 이용한 자기변형 위치변환기)

  • Lee, Heung-Shik;Cho, Chong-Du;Lee, Sang-Kyo
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1617-1620
    • /
    • 2007
  • This paper presents a magnetostrictive transpositioner and its fabrication process. To get a transposition movement without shifting or twisting, it is designed as an array type. To fabricate the suggested design, micromachining and selective DC magnetron sputtering processes are combined. TbDyFe film is sputter-deposited on the back side of the bulk micromachined transpositioner, with the condition as: Ar gas pressure below $1.2{\times}10^{-9}$ torr, DC input power of 180W and heating temperature of up to $250^{\circ}C$ for the wireless control of each array component. After the sputter process, magnetization and magnetostriction of each sample are measured. X-ray diffraction studies are also carried out to determine the film structure and thickness of the sputtered film. For the operation, each component of the actuator has same length and out-of-plane motion. Each component is actuated by externally applied magnetic fields up to 0.5T and motion of the device made upward movement. As a result, deflections of the device due to the movement for the external magnetic fields are observed.

  • PDF

Effects of interface delay in real-time dynamic substructuring tests on a cable for cable-stayed bridge

  • Marsico, Maria Rosaria
    • Smart Structures and Systems
    • /
    • v.14 no.6
    • /
    • pp.1173-1196
    • /
    • 2014
  • Real-time dynamic substructuring tests have been conducted on a cable-deck system. The cable is representative of a full scale cable for a cable-stayed bridge and it interacts with a deck, numerically modelled as a single-degree-of-freedom system. The purpose of exciting the inclined cable at the bottom is to identify its nonlinear dynamics and to mark the stability boundary of the semi-trivial solution. The latter physically corresponds to the point at which the cable starts to have an out-of-plane response when both input and previous response were in-plane. The numerical and the physical parts of the system interact through a transfer system, which is an actuator, and the input signal generated by the numerical model is assumed to interact instantaneously with the system. However, only an ideal system manifests a perfect correspondence between the desired signal and the applied signal. In fact, the transfer system introduces into the desired input signal a delay, which considerably affects the feedback force that, in turn, is processed to generate a new input. The effectiveness of the control algorithm is measured by using the synchronization technique, while the online adaptive forward prediction algorithm is used to compensate for the delay error, which is present in the performed tests. The response of the cable interacting with the deck has been experimentally observed, both in the presence of delay and when delay is compensated for, and it has been compared with the analytical model. The effects of the interface delay in real-time dynamic substructuring tests conducted on the cable-deck system are extensively discussed.

Design and Performance Evaluation of Mini-Lightweight Piezo-Composite Actuators

  • Tran, Anh Kim;Yoon, Kwang-Joon
    • Advanced Composite Materials
    • /
    • v.18 no.4
    • /
    • pp.327-338
    • /
    • 2009
  • In this paper, through an evaluation process conducted on several designs of mini-LIPCA (Lightweight Piezo-Composite curved Actuator), an optimal design of a mini-LIPCA has been proposed. Comparing with the LIPCA-C2, the design of the mini-LIPCA comes with reduced overall size and a thinner active layer. Since a variation in the number and lay-up of fiber composite layers may strongly affect the performance of the device, one is able to configure several designs of mini-LIPCA. The evaluation process is then followed in order to determine a configuration which characterizes the possibly optimal performance. That is, a design of a mini-LIPCA is said to be optimal if it is capable of producing a maximum out-of-plane displacement. The size of the LIPCA to be investigated was selected to be $10\;mm\;{\times}\;20\;mm$ in which the thickness of PZT plate is about 0.1 mm. The thickness of glass/epoxy and carbon/epoxy are about 0.09 mm and 0.1 mm, respectively. The evaluation process has been conducted thoroughly, i.e., analytical estimation, numerical approximation and the experimental measurement are all involved. Firstly, the design equation was used to calculate essential parameters of proposed lay-up configurations. Secondly, ANSYS, a commercial FEA package, was utilized to estimate displacement outputs of the actuators upon being excited. Finally, experimental measurements were able to verify the predicted results.

Fabrication of Micro-optical Components and Actuators using Surface Micromachining (표면 미세가공기술을 이용한 마이크로 광학소자 및 구동기의 제작)

  • Kim, K.N.;Park, K.B.;Jung, S.W.;Lee, B.N.;Kim, I.H.;Moon, H.C.;Park, H.D.;Shin, S.M.
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1151-1153
    • /
    • 1999
  • 3-layer polysilicon 표면미세가공공정을 이용하여 micro zone plate 렌즈와 미러 및 이를 구동하기 위한 구동기를 일체화시킨 마이크로 구동형 광학소자를 설계, 제작하였다. 650nm의 파장대역에서 초점거리가 $500{\mu}m$가 되도록 마이크로 zone plate 렌즈를 설계하였으며, 렌즈의 광학축은 실리콘 기판 상에서 $121{\mu}m$거리에 위치하도록 제작하였다. 마이크로 hinge와 스프링 latch 및 측면지지 plate를 이용하여 마이크로 렌즈와 미러가 실리콘 기판상에서 out-of-plane동작이 가능하도록 하였다. 마이크로렌즈 초점거리의 가변을 위하여 6개의 SDA(Scratch Drive Actuator)어레이를 설계, 제작하였다. 또한 빔 반사를 위한 마이크로 미러를 설계하고 $45^{\circ}$ self-assembly를 위하여 마이크로 hinge와 SDA array를 제작하였다.

  • PDF

Experiments on Flexural Performance of Composite Members Strengthened by External Steel Plates (외부 강재 보강으로 구성한 합성 부재의 휨 성능에 대한 실험)

  • Hwang, Byung-Hun;Shin, Jin-Won;Jeon, Jae-Ho;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.143-150
    • /
    • 2022
  • This paper presents an experimental study on the flexural performance of concrete members strengthened with external steel plates for the purpose of improving seismic performance. In order to strengthen the structure, a strengthening method was applied that wraps the walls and columns with steel members. The partial section of the wall with the longest span in the structure was manufactured in real size and the strengthening effect was confirmed by performing a static load test. As a result of the experiment, it was confirmed that the strengthened section exhibited sufficient flexural performance satisfied to the seismic requirements, but the behavior until failure was not obtained because of actuator capacity. It was confirmed that the strengthened member resists the out-of-plane moment with a composite behavior. It was verified that the stiffness and load carrying capacity of the strengthened member were improved compared to the non-strengthened member by displacement and strain measurements.