• Title/Summary/Keyword: Optometry

Search Result 582, Processing Time 0.023 seconds

Analysis of Employment Tendencies According to the Satisfaction of Field (Clinical) Practice among Students of the Department of Optics (안경광학과 학생들의 현장(임상)실습 만족도에 따른 취업 성향 분석)

  • Choi, Gye-Hun
    • Journal of Korean Clinical Health Science
    • /
    • v.4 no.4
    • /
    • pp.671-679
    • /
    • 2016
  • Purpose. This research study is to understand the effects of field (clinical) Practice on employment choice and decision. Method. The research study conducts a questionnaire survey of trainees who received field (clinical) Training during the period of 2016 summer vacation to analyze the data, utilizing Likert 5 rating scales and conduct a statistical analysis with the tool of SPSS 18.0. Results.. As for the satisfaction of the participation of Practice, girl students account for the high rate (75.1%) compared with boy students (61.7%). Regarding the satisfaction of each Practice spot, ophthalmic clinic reaches the high rate (77.8%) compared with optical shop (65.7%). Practice about practice courses (53.2%) of regular subjects have somewhat close correlations compared with theory courses (46.8%). 75.2% of respondents in the group that shows the high satisfaction of the participation of Practice replied that they would decide employment as an academic major after Practice. And the figure is proved to assume a high ratio. Conclusion. The analytic research outcome indicates that those trainees who received Practice in an ophthalmic clinic have higher satisfaction than those who received Practice in an optical shop. There is the high accomplishment of employment in relation to academic major area instead of other area, after Practice.

Effects of Aggressive Stress Response Mediation on Clinical Practice Stress and Satisfaction (적극적 스트레스 대처매개 중재가 임상실습 스트레스와 만족도에 미치는 영향)

  • Lee, Jeong-Yun;Hwang, Hye-Kyung
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.2
    • /
    • pp.1345-1354
    • /
    • 2019
  • Purpose: This study aimed to determine the mediating effects of aggressive stress response on the association between clinical practice stress and clinical practice satisfaction in ophthalmic optics majors and provide basic data that could help form opticians' professionalism and make clinical practice more effective. Methods: This study was conducted in 236 sophomores and juniors in Daegu and North Gyeongsang Province who had finished clinical practice. Hierarchical regression analysis and mediating effect testing were performed to determine the associations among clinical practice stress, clinical practice satisfaction, and aggressive stress response and determine the mediating effects of aggressive stress response on the association between clinical practice stress and clinical practice satisfaction. Results: Clinical practice stress was significantly negatively correlated with clinical practice satisfaction and aggressive stress response (p<0.01), and aggressive stress response was significantly positively correlated with clinical practice satisfaction (p<0.01). The association between clinical practice stress and clinical practice satisfaction was more likely to be explained by the addition of clinical practice stress than by being aggressive stress response controlled, which statistically significantly met the criteria for mediating effects (p<0.001). Conclusions: It is necessary to pay more attention to program development and teaching methods within the department of ophthalmic optics so that ophthalmic optics majors can utilize aggressive stress response to overcome clinical practice stress effectively and improve clinical practice satisfaction.

Interfacial and Rheological Properties of Selected Hydrogel Formulations for Soft Contact Lens (소프트 콘텍트 렌즈용 하이드로젤의 계면학적 및 유변학적 특성 연구)

  • Noh, Hye-Ran
    • Polymer(Korea)
    • /
    • v.36 no.2
    • /
    • pp.190-195
    • /
    • 2012
  • Interfacial and rheological properties of selected hydrogel formulations were studied to understand the contact-lens comfort in end use. It was concluded that protein adsorption from aqueous solution decreased monotonically with increasing surface energy (water wettability) of tested hydrogels. Also, it has revealed that friction coefficient of polydimethylsiloxane-polyvinylpyrrolidone (PDMS-PVP) was significantly larger that 2-hydroxyethyl methacrylate (HEMA) based hydrogels. Interestingly, in artificial tear solution, friction coefficients of HEMA based hydrogels were larger than silicone hydrogels.

Orthoscopic real image reconstruction in integral imaging by modifying coordinate of elemental image (집적영상에서 요소영상의 좌표변환을 이용한 정치실영상 구현)

  • Jang, Jae-young;Cho, Myungjin
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.7
    • /
    • pp.1646-1652
    • /
    • 2015
  • In this paper, we propose a depth conversion method for orthoscopic real image reconstruction in integral imaging. Pseudoscopic image has been regarded a problem in conventional integral imaging. the depth of reconstructed image is depending on a coordinate of an elemental image. The conversion from pseudoscopic to orthoscopic may be possible by analysing the geometrical relation between pickup and reconstruction system of elemental image. The feasibility of the proposed method has been confirmed through preliminary experiments as well as ray optical analysis.

Color soft contact lens and corneal thickness

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.7 no.1
    • /
    • pp.1205-1214
    • /
    • 2019
  • Purpose: To investigate the effect of color soft contact lenses on the corneal thickness in young Korean population. Methods: The subjects consisted of 112 eyes (7 males, 49 females) with the mean age of $20.987{\pm}1.093years$ (range 20-25 years) in young Korean population during 2018. Test was compared the corneal thickness before and after wearing color soft contact lenses. The thinnest cornea thickness(TCT), central cornea thickness(CCT), pupil centre thickness(PCT), superior corneal thickness(SCT),inferior corneal thickness(ICT), medial corneal thickness(MCT), lateral corneal thickness(LCT) of the cornea was measured using the Pentacam pachymetry. The statistically analysis was perform the Shaparo-Wilk test. Results: The right eye was a statistically significant among the CCT,LCT, MCT and TCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. Also the left eye was a statistically significant among the LCT and MCT values(p<0.001) in the compared the corneal thickness before and after wearing soft colour contact lenses. However, there was no statistical difference (p>0.5) in the mean PCT between before and after wearing color soft contact lenses. Conclusion: These results suggested that the color soft contact lens wear can the effect the regional thickness of cornea. Therefore, the analysis of corneal topography with Pentacam can provide correct and useful diagnostic information of the morphology of the RGP contact lens fitting and diagnosis of corneal refraction surgery.

Thermographic assessment on temperature change of skin surface in frame fitting point (열화상 카메라를 활용한 frame fitting point의 표면 온도 분석)

  • Joo, Byung Hyuk;Park, Chang Won
    • Journal of Korean Clinical Health Science
    • /
    • v.9 no.1
    • /
    • pp.1462-1468
    • /
    • 2021
  • Purpose; The purpose of this study is to objectively identify and quantify the wearer's feelings of wearing glasses. Methods: The temperature of the skin on the nose ridges and ear, and the area where the glasses were seated, was measured using a thermal imaging camera. Results: Before wearing the glasses, the temperature of the skin surface on the nasal ridge was 34.908 ± 0.875 ℃ and the temperature of the ear region was determined as 31.981 ± 0.549 ℃. The changed temperature measured at 5 minutes later after taking off the glasses showed that the nasal ridge was determined as 35.467 ± 0.342 ℃ and the ear area was determined as 32.994 ± 0.412 ℃ (p<0.05). Conclusions: In this experiment, it was revealed that the glasses cause discomfort and heat in the fitting area. It was the first attempt to study objectively and scientifically. Analysis of frame fitting points by using thermal camera is expected to be helpful when consulting a sensitive person about changes in the fit of glasses.

Association between astigmatism and amblyopia.

  • Sapkota, Kishor;Kim, Douk Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.10 no.1
    • /
    • pp.1553-1558
    • /
    • 2022
  • Purpose: The aim of this study was to determine the association between stigmatism and amblyopia. Methods: It was a hospital based, cross-sectional retrospective study conducted in Nepal Eye Hospital. Medical record of amblyopic children aged 13 years or younger from were reviewed. Children with amblyopic eyes due to simple astigmatism were included. Relation between depth of amblyopia with magnitude and types of astigmatism, orientation of axis was determined. Out of 139 amblyopic eyes of 82 children, 93 were simple myopic astigmatism and remaining 42 were simple hyperopic astigmatism. Results: Mean age of patients was 7.38±2.61 years. Visual acuity improved by at least one line in Snellen chart in 4/5th of eyes after astigmatic correction. Moderate amblyopia was found to be present in 45% eyes while severe amblyopia in 16% of eyes. With the rule astigmatism was found to be present in 88% eyes. Mean astigmatism was 2.47±0.98D and majority of eyes (67.7%) had high astigmatism. Depth of amblyopia was not associated with magnitude of astigmatism (p > 0.05) but number of lines improved with astigmatic correction was correlated with the magnitude of astigmatism (p < 0.001). Risk of amblyopia is more in high myopic astigmatism. Conclusion: Presenting age of amblyopic children was late in Nepal. Depth of amblyopia was not associated with magnitude of astigmatism.

Analysis of cornea thickness and intra ocular pressure of 20 to 24 years old population in Korea (한국인 20세부터 24세까지 각막 두께와 안압의 분석)

  • Douk Hoon Kim;Kishor Sapkota
    • Journal of Korean Clinical Health Science
    • /
    • v.11 no.1
    • /
    • pp.1632-1638
    • /
    • 2023
  • Purpose: The aim of this study was to determine the distribution of the cornea thickness and intra ocular pressure Korean adult of 20 to 24 year old using the Pentacam and tonometer. Methods: The subjects of this study were 43 Korean adults with healthy eyes. Corneal thickness was measured with Pentacam device. The intra ocular pressure was measured with tonometer. Data was analyzed by means of the Pearson's correlation cofficient. P-values<0.001 were considered statistically significant. Results: Mean age of subjects was 20.41±0.86 years. The mean +/- intra ocular pressure of the right eye and left eye were 16.236±2.523mmHg and 16.971±1.992mmHg, respectively. The mean central corneal thickness of the right eye and left eye was 545.324±38.682㎛ and 547.442±33.778㎛, respectively. No significant difference in central corneal thickness was found between the right and left eyes. But, there was a statistically significant difference between central cornea thickness and peripheral cornea thickness around 4 mm of central cornea(p<0.001, Pearson's correlation). However there was no statistically significant difference between central cornea thickness and intra ocular pressure. Conclusion: The results of this study could be used as a clinical reference data for diagnosis and treatment of cornea in Korean adult.

Difference between Manifest Refraction (MR) and Cycloplegic Refraction (CR) with Age and Myopic Value (연령과 근시도에 따른 현성굴절검사와 조절마비굴절검사의 비교)

  • Jeong, Woo-Jae;Kang, Ji-Hun;Jeon, In-Chul
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.1
    • /
    • pp.85-91
    • /
    • 2013
  • Purpose: The purpose of this study is to investigate difference between manifest refraction (MR) and cycloplegic refraction (CR) with age and myopic value. Methods: Manifest and cycloplegic refractions were carried out on the patients of 229 myopic patients ($25.3{\pm}11.9$ years old). Results: The average results from a pre- and a postcycloplegic refraction showed a reduction of 0.19 D in myopia, 0.02 D in astigmatism and $1.85^{\circ}$ in astigmatism direction. Change of myopic value was higher in 30~40 age. Total 73 eyes of 229 patients who showed 0.50 diopter (D) in spherical, and a high degree of myopia group showed a higher discrepancy rate. Conclusions: The results found in the comparison of the value of the manifest refraction and cycloplegic refractions showed changes of myopic value was not significant with age of patient, but the group of high degree of myopia showed higher discrepancy rate.

The Relationship between Refractive Myopia and Corneal Astigmatism in Korea Women University Students (한국 여자대학생의 굴절성 근시와 각막난시 관계)

  • Kim, Douk-Hoon
    • Journal of Korean Clinical Health Science
    • /
    • v.1 no.1
    • /
    • pp.1-7
    • /
    • 2013
  • Purpose. To analysis the prevalence of the myopia and corneal astigmatism in Korea women university students. Methods. From August 2011 to December 2012, one hundreds subjects were performed in refraction test using the Auto-Keratometry. Results. The mean age of the 100 subjects (200 eyes) was $21.23{\pm}2.34$. The mean spherical refractive power was -$1.78{\pm}1.65$(OD) and -$1.83{\pm}1.67$(OS) Diopter. The mean astigmatism power was $1.22{\pm}0.96$ (OD) and $1.27{\pm}0.91$ (OS). The mean corneal astigmatism was $1.44{\pm}0.81$(OD) and $1.55{\pm}0.93$(OS). Corneal astigmatism was between 0.25 D and 1.25 D in 67.7% of eyes, 1.25 D or higher in 27.5% eyes, and less than 0.25 D in 4.8% of eyes. Astigmatism was with the rule in 65%, against the rule in 31.5%, and oblique in 3.5%. There was a statistical significance between right eye and left eye in the spherical equivalent power(p=0.002). Also there was a statistical significance between spherical power and refractive astigmatism in OD(p=0.006) and OS(0.003) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.0003). However, there was not a statistical significance between spherical power and corneal astigmatism in OD(p=0.08) and OS(0.1) and a statistical significance between corneal astigmatism and refractive astigmatism in OS(p=0.48). Conclusions. In this study, these results suggested that the analysis of the refractive myopia and corneal astigmatism can provide the visual correct and useful diagnosis information for the eyewear dispensing, contact lens fitting and corneal refraction surgery.

  • PDF