A Study on the cucumber growth by soil warming and warmed water irrigation using solar energy system(3) (태양열 시스템을 이용한 가온관수와 지중가온 방법에 의한 오이의 생육 연구(3))

  • 구건효;김태욱;김진현
    • Journal of Bio-Environment Control
    • /
    • v.8 no.1
    • /
    • pp.1-8
    • /
    • 1999
  • This study was carried out to estimate the warmed water irrigation and the warmed soil efficiency on protected cultivation of cucumber in winter season. The water of 28$^{\circ}C$ was continuously supplied for soil warming and that is $25^{\circ}C$ for warmed water irrigation. Cucumber growth was analyzed when tile soil kept up the optimum temperature in the root zone. The cucumber growth are compared with the warmed soil plots. isolated warmed soil plots and non-warmed soil plots. The cucumber growth in warmed soil plots and isolated warmed soil plots were 20~50% higher than non-warmed soil plots compare to that by the warmed irrigation. In the non-warmed soil plots, the stem diameter and the number of leaves in the warmed water irrigation plots are 10% higher than those in the normal water irrigation plots. The yields in isolated warmed soil plots were 37~38% higher than non-warmed soil plots and those in warmed soil plots were 85~96% higher than non-warmed soil plots. The fruit length, weight and diameter in warmed soil plots were 15% higher than those in the non-warmed plots.

  • PDF

Investigation on Conservation Environment of the Seokguram Grotto (National Treasure No. 24) (국보 제24호 석굴암의 보존환경)

  • Hong, Jung-Ki;Eom, Doo-Sung
    • 보존과학연구
    • /
    • s.24
    • /
    • pp.169-184
    • /
    • 2003
  • Yearly mean temperature and relative-humidity of the Seokguram Grotto was measured $19~23^{\circ}C$, 40~44% from May, 1998 to December,2002. The measurement has little differences comparing to the optimum guideline (temperature : $20^{\circ}\pm2^{\circ}C$, relative-humidity : $50^{\circ}\pm5%$). It is necessary to increase humidity in the Seokguram Grotto during winter because of heating and decrease the temperature during summer because of a higher temperature of outside. In addition, the diurnal range keep in $4^{\circ}C$ of temperature and in 10% of relative-humidity. Yearly mean concentration of $CO_2$(carbon dioxide) was measured538~658ppm that is higher than concentration of normal atmosphere(360 ppm). The $CO_2$ has an cumulative effect on the surface of stone cultural properties as a form of carbonic acid($H_2CO_3$) after reaction with water. HVAC (Heating, Ventilation and Air Conditioning) system should be operated to maintain ideal state for the preservation according to the optimum guideline. Also, the entrance into the Seokguram Grotto should be controlled to prevent a sudden fluctuation of humidity and temperature. Human could carry small particles like a microdust, microbe, etc., into the Seokguram Grotto and also could damage the surface by a direct touch.

  • PDF

An Experimental Study on the Condensation Characteristics of Sea Water in the Tilted Box with Solar Radiation (태양열을 받는 경사진 육면체 내 해수의 응축특성에 관한 실험적 연구)

  • Kim, Beom-Han;Kim, Byung-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.31 no.4
    • /
    • pp.27-33
    • /
    • 2011
  • To find effective way of the production of distilled water for drought and flood with solar radiation, three boxes were made same base each 1000mm ${\times} $1000mm and tops are 45 degree. Individual boxes contained the sea water, rain water and surface water were placed at the same location and same time. Condensation of each box has been compared. On clear day production of distilled water in the box with sea water was 36% and 32% less than boxes with rain water and surface water. The maximum condensation reached when the temperature of the top and bottom parts are equal. As concentration of sea water increased production of distilled water was decreased. In the box with sea water, the surface temperature was lower than 3cm below the surface. Optimum collector area for producing distilled water 2000ml of these three boxes were $3.75m^2$

An Experiment on the Optimum Growth Temperature and Wintering Temperature of the Catfish, Clarias batrachus, in the Aquarium (열대산메기, Clarias batrachus의 수조내사육시의 적정사육 수온과 월동수온에 관한 연구)

  • JO Jae-Yoon
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.3
    • /
    • pp.197-205
    • /
    • 1984
  • From 1981 to 1982, a series of experiments on the optimum growth temperature, wintering temperature and lethal minimum temperature of the walking catfish Clarias batrachus, of about 12 to 40 g yearlings, were carried out using indoor recirculating aquariums at water temperature between $14^{\circ}C\;and\;34^{\circ}C$. The results are as follows. The optimum temperature of this species was turned out to be approximately $25^{\circ}C$ with highest feed intake and growth rates, and lowest conversion rate than at any other temperatures. The minimum temperature at which the fish can show growth turned out to be $18^{\circ}C$, At this temperature daily growth rate for 62 days was about $0.1\%$ and all fish survived. When this species was kept at $16^{\circ}C$ or lower, no fish survived more than one month and at lower than $14^{\circ}C$ all fish died out in 1 to 7 days. In accordance with these results it could be inferred that $18^{\circ}C$ is the minimum wintering temperature. Rearing this species at the minimum growth temperature for a long time, for wintering for instance, the sudden change of water temperature, especially decreasing to lower than $15^{\circ}C$ can be lethal for all fish.

  • PDF

Evaluation on solubility and vapor pressure of H2O/(LiBr+CaCl2) solution as a working fluid (H2O/(LiBr+CaCl2) 3성분계 흡수용액의 용해도 및 증기압 특성 평가)

  • No, S.Y.;Jang, Y.H.;Koo, K.K.;Jeong, S.;Kim, Y.W.;Kim, S.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.2
    • /
    • pp.163-170
    • /
    • 1997
  • Solubility on $(LiBr+CaCl_2)$ in water has been measured systematically and compared with those of pure LiBr. It has been observed that there exists optimum value of $CaCl_2(LiBr+CaCl_2)$ in solubility when total$(LiBr+CaCl_2)$ concentration is higher than 57wt%. As total concentration increases up to 65wt%, it is found that the optimum value also increases monotonically. From the experimental results, a master plot has been constructed, with which optimum ratio of LiBr to $CaCl_2$ can be found in terms of total concentration. Vapor pressure of $H_2O/(LiBr+CaCl_2)$ solution with optimum contents of $CaCl_2$ has been observed to be changed negligibly at relatiely low temperature. However, as temperature increases, it is found that increasement in vapor pressure is significant.

  • PDF

Studies on Magnesia Production. Production of Magnesium Hydroxide from Bittern and Sea Water (마그네시아 製造에 關한 硏究 간수, 海水로 부터 水酸化마그네슘 製造)

  • Maeng, Jung-Jae;Chang, In-Soon
    • Journal of the Korean Chemical Society
    • /
    • v.9 no.1
    • /
    • pp.49-54
    • /
    • 1965
  • One of the difficult and time consuming problems in the production of magnesia from sea water is a settling rate of magnesium hydroxide. In this experiments, authors attempted to accelerate its settling rate by addition of various sedimenting agents as C.M.C., Separan and Starch, and sought for optimum calcination temperature for domestic dolomite, as alkali source, mole ratio of dolomite milk to bittern. It is observed through experiments that the small amounts of sedimenting agents, C.M.C., Separan, starch, 20 mg/l, 40 mg/l, 400mg/l, respectively increase the settling rate of magnesium hydroxide by 8 times or more. The following conditions resulted in good yield of magnesium hydroxide from sea water with relatively tolerable calcium oxide contaminated for the magnesium clinker. Calcinating temperature, $1,100{\sim}1,200^{\circ}C$, mole ratio of 10% dolomite milk to magnesium salts in sea water or bittern, 1. 2 : 1.

  • PDF

Dynamic Analysis of Single-Effect/Double-Lift Libr-Water Absorption System using Low-Temperature Hot Water (저온수를 이용하는 일중효용/이단승온 리튬브로마이드-물 흡수식 시스템의 동적 해석)

  • Kim, Byong-Joo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.12
    • /
    • pp.695-702
    • /
    • 2009
  • Dynamic behavior of Libr-water absorption system using low-temperature hot water was investigated numerically. Thermal-hydraulic model of single-effect/double-lift 100 RT chiller was developed by applying transient conservation equations of total mass, Libr mass, energy and momentum to each component. Transient variations of system properties and transport variables were analysed during start-up operation. Numerical analysis were performed to quantify the effects of bulk concentration and part-load operation on the system performance in terms of cooling capacity, coefficient of performance, and time constant of system. For an absorption chiller considered in the present study, optimum bulk concentration was found to exist, which resulted in the minimum time constant with stable cooling capacity. COP and time constant increased as the load decreased down to 40%, below which the time constant increased abruptly and COP decreased as the load decreased further.

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

Relationship Between the Catch of the Pacific Saury and the Water Temperature in the Northwest Pacific Ocean (북태평양 꽁치 봉수망 어획량과 수온과의 관계)

  • 조현수
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.3
    • /
    • pp.249-256
    • /
    • 1996
  • The saury stick - held dip net fishery of Korea in the Northwest Pacific Ocean began in 1985 with 3 vessels. Since then the fishery has grown so rapidly year by year that the number of vessels increased to 34 and the catch to 40 thousands Mff in 1993. In the present study, the monthly situation and the movement of the fishing ground for the pacific saury in the Northwest Pacific were investigated and the monthly optimum fIshing tempertures were estimated, from the relationship between the catch and the sea surface temperature. In the beginning of the fishing season, June to August, the fIshing ground is formed in the very wide range, mainly in the northward area of the front meandering, as the parcific saury migrate northward. In the main season, September to November, the ground is formed in the southward area of the front, off the east coast of Japan. Andd then, the fishing season ends in December with the ground coming near to the east coast of Japan. The monthly optimum fishing tempertures showed 11~$13^{\circ}C.$ in June to July, 13-$17^{\circ}C.$ in August to November, and 15~ $17^{\circ}C.$ in December in general. The profIles of water temperature were much different in accordance by net casting position in the fishing ground, regardless of season. So, the MLD and CPUE was analyzed to find out the relation between the water temperature and the catch. Then, it is found that the CPUE shows over 0.7Mtr/haul as the MLD 40~70m.40~70m.

  • PDF

Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source (저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석)

  • Kim, Kyoung-Hoon;Ko, Hyung-Jong;Kim, Se-Woong
    • Journal of Hydrogen and New Energy
    • /
    • v.23 no.1
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.