• Title/Summary/Keyword: Optical Set-Up

Search Result 158, Processing Time 0.025 seconds

Fabrication and Packaging of Planar Waveguide Brags Grating (평판도파로 브래그격자 제조 및 접속)

  • 한준모;최준석;문형명;임기건;이형종;최두선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.141-144
    • /
    • 2002
  • Computer code was developed to design waveguide gratings based on coupled-mode equations and the transfer matrix formalism. The experimental set-up has been constructed for inscribing Bragg gratings in planar waveguides with a phase mask and uv laser beam, which enables alignment and packaging of grating devices as well as in-situ performance measurements. Bragg grating has been fabricated on silica planar waveguides with 0.75% Germanium concentration and its transmittance spectrum was measured to have 95% reflectance at the peak wavelength. Optical losses as the function of the misalignment were measured and their usage is described.

  • PDF

Efficient Approach to Measure Crystallization Temperature in Amorphous Thin Film by Infrared Reflectivity

  • Wang, Wenxiu;Saito, Shin;Yakabe, Hidetaka;Takahashi, Migaku
    • Journal of Magnetics
    • /
    • v.18 no.2
    • /
    • pp.86-89
    • /
    • 2013
  • This paper shows a new effective approach to measure crystallization temperature of soft magnetic underlayer (SUL) for next generation of heat assisted perpendicular recording media. This approach uses temperature dependent reflectivity, which shows a clear jump when samples are crystallized. To achieve this measurement, an optical system is set up using hot plate and infrared laser. Reflectivity of SUL $(Co_{70}Fe_{30})_{92}Ta_3Zr_5$ shows a clear jump at its amorphous-crystalline transition temperature. Experiment results show this effect is clear in infrared region, and is weak for visible light.

Development of Multi-wavelength Laser Medical Therapy Apparatus (다파장 레이저치료기의 개발)

  • Cheon, Min-Woo;Kim, Seong-Hwan;Park, Yong-Pil;Lee, Ho-Sik;Kim, Tae-Gon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.8
    • /
    • pp.736-741
    • /
    • 2007
  • Low level laser therapy has various therapy effects, This paper performed the basic study for fabricating the low level laser therapy apparatus, and one of the goals of this paper was to make this apparatus used handily. The apparatus has been fabricated using the laser diode and microprocessor unit. The apparatus used a 660nm, 785nm and 850nm laser diode for laser medical therapy and was designed for a pulse width modulation type to increase stimulation effects. To raise the stimulus effect of the human body, the optical irradiation frequency could be set up. In result, the $1{\sim}10\;Hz$ irradiation frequency could be controlled stably.

A Case Study on the Compatibility Analysis of Measurement Systems in Automobile Body Assembly

  • Lee, Myung-Duk;Lim, Ik-Sung;Sung, Chun-Ja
    • International Journal of Reliability and Applications
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2008
  • The dimensional measurement equipment, such as Coordinate Measurement Machine (CMM), Optical Coordinate Measurement Machine (OCMM), and Checking Fixture (CF), take multiple dimensional measurements for each part in an automobile industry. Measurements are also recorded under different measurement systems to see if the responses differ significantly over these systems. Each measurement system (CMM, OCMM, and CF) will be considered as different treatments. This set-up provides massive amounts of process data which are multivariate in nature. Therefore, the multivariate statistical analysis is required to analyze data that are dependent on each other. This research provides step by step methodology for the evaluation procedure of the compatibility of measurement systems and clarify a systematic analyzation among the different measurement system's compatibility followed by number of case studies for each methodologies provided.

  • PDF

Characterization of Microscale Objects based on the Diffraction Pattern Analysis (회절무늬를 이용한 미세물체의 특성 측정)

  • 강기호;전형욱;손정영;오명환
    • Korean Journal of Optics and Photonics
    • /
    • v.2 no.1
    • /
    • pp.1-6
    • /
    • 1991
  • This paper describes the theoretical analysis of a diffraction pattern analyzer for the characterization of microscale object fields and a method for obtaining size and size distribution from the measured diffraction pattern of the object fields. For the experimental verification, a typical optical Fourier transform system was set up and calibrated with 2 5$\mu \textrm m$ and 50$\mu \textrm m$ pinholes. The system responses to distilled water droplets, alcohol, glycerin and silicon oil were imaged with vidicon, and the image was processed to determine the size distribution of each liquid particle field. The energy distribution function which is defined as the total intensity of a circular ring in the diffraction pattern was used to determine the dominant particle size of each liquid particle field.

  • PDF

Pressure Dependence of Acoustic Properties of Liquid Ethanol by using High-pressure Brillouin Spectroscopy

  • Ko, Jae-Hyeon;Jeong, Min-Seok;Lee, Byoung Wan;Kim, Jae Hyun;Ko, Young Ho;Kim, Kwang Joo;Kim, Tae Hyun;Kojima, Seiji;Ahart, Muhtar
    • Korean Journal of Optics and Photonics
    • /
    • v.24 no.5
    • /
    • pp.279-286
    • /
    • 2013
  • Brillouin spectroscopy has been widely used for the investigation of acoustic properties of condensed matters in the hypersonic region. A high-pressure Brillouin spectrometer was set up by combining a diamond anvil cell and a tandem multi-pass Fabry-Perot interferometer. It was successfully applied to liquid ethanol, and the pressure dependence of the sound velocity, the refractive index and other acoustic properties were derived based on the measurements. The detailed optical setup and experimental procedure are described.

A Novel Calibration Method Research of the Scale Factor for the All-optical Atomic Spin Inertial Measurement Device

  • Zou, Sheng;Zhang, Hong;Chen, Xi-yuan;Chen, Yao;Fang, Jian-cheng
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.415-420
    • /
    • 2015
  • A novel method to measure the scale factor for the all-optical atomic spin inertial measurement device (ASIMD) is demonstrated in this paper. The method can realize the calibration of the scale factor by a self-consistent method with small errors in the quiescent state. At first, the matured IMU (inertial measurement unit) device was fixed on an optical platform together with the ASIMD, and it has been used to calibrate the scale factor for the ASIMD. The results show that there were some errors causing the inaccuracy of the experiment. By the comparative analysis of theory and experiment, the ASIMD was unable to keep pace with the IMU. Considering the characteristics of the ASIMD, the mismatch between the driven frequency of the optical platform and the bandwidth of the ASIMD was the major reason. An all-optical atomic spin magnetometer was set up at first. The sensitivity of the magnetometer is ultra-high, and it can be used to detect the magnetization of spin-polarized noble gas. The gyromagnetic ratio of the noble gas is a physical constant, and it has already been measured accurately. So a novel calibration method for scale factor based on the gyromagnetic ratio has been presented. The relevant theoretical analysis and experiments have been implemented. The results showed that the scale factor of the device was $7.272V/^{\circ}/s$ by multi-group experiments with the maximum error value 0.49%.

Tolerance design of position accuracy of optical components for micro optical system (마이크로 광 시스템 구현을 위한 광학 부품의 위치 정밀도 허용오차 설계)

  • 이재영;황병철;박헌용;박세근;이승걸;오범환;이일항;최두선
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.41 no.7
    • /
    • pp.13-20
    • /
    • 2004
  • In order to set up the design of micro optical bench, optical coupling efficiencies of two sets of test benches are calculated. Simple linear connections of incoming and outgoing optical fibers with and without ball lenses are designed. Positional errors that are possible in actual fabrication processes we considered in the calculations and their tolerances are determined from -3 ㏈ conditions. For a simple fiber-to-fiber connection, the lateral misalignment should be limited to 2.7 um and tilt error 5.8o. In case of the fiber-to-fiber with ball lens, the working distance between fibers can be extended over 60 um. The optical coupling efficiency depends strongly on the positional errors of ball lenses along the optical axis, and it is also found that the lateral and vertical positional errors should be considered simultaneously in order to keep the high coupling efficiency.

Design and Implementation of Auto Set-up Program for SFP Module by using VEE (VEE를 이용한 SFP 모듈 자동 설정 프로그램 설계 및 개발)

  • Choi, Jeoung-Hoon;Jun, Byung-Uk;Koo, Yong-Wan
    • Journal of Internet Computing and Services
    • /
    • v.8 no.2
    • /
    • pp.67-76
    • /
    • 2007
  • Data used for the SFP module are stored in A0 and A2 memory area based on the SFP-MSA standard. In this paper the auto set-up program for SFP module has been designed and implemented. In order to make the Digital Diagnostic Monitoring Interface, the specific value has been written into the designated register via RS232 communication channel in the LD Driver IC. The Agilent VEE is used as a programming language for factory automation, and optical characteristics of SFP module and SFP-MSA standard are main structure of the implementation. The implemented program has been applied to the manufacturing field and the system gains a higher effect than the result of 6-Sigma.

  • PDF

The electro-optic properites measurement of the side-chain polymer flim (측쇄결합 폴리머 필름의 전기광학 특성 측정)

  • 김광택;이소영;이남권;송재원;박이순;금창대
    • Korean Journal of Optics and Photonics
    • /
    • v.9 no.4
    • /
    • pp.215-220
    • /
    • 1998
  • We proposed an in situ measurement set-up and technique to measure the various electro-optic(E-O) properties of the E-O polymer. Using the proposed measurement set-up, the electro-optic effect and birefringence of unpoled side-chain E-O polymer induced by the strong dc and ac electric field were observed. The dependence of the E-O coefficients on the various poling conditions were measured with real time. To evaluate the thermal stability of the poled polymer the relaxation of the E-O effect was measured and the result was compared with well known polymer materials. The proposed measurement reduces the number of experimental steps and saves measurement time.

  • PDF